BACKGROUND: Heart transplantation (HTx) is an established therapeutic option for children with end-stage heart failure. Comprehensive pediatric nationwide HTx program was introduced in 2014 in the Czech Republic. The aim of this study was to evaluate its mid-term characteristics and outcomes and to compare them with international data. METHODS: Retrospective observational study, including all patients who underwent HTx from June 2014 till December 2022. Data from the institutional database were used for descriptive statistics and survival analyses. RESULTS: A total of 30 HTx were performed in 29 patients with congenital heart disease (CHD, N = 15, single ventricular physiology in 10 patients) and cardiomyopathy (CMP, N = 14). Ten patients were bridged to HTx by durable left ventricular assist devices (LVADs) for a mean duration of 104 (SD 89) days. There was one early and one late death during median follow-up of 3.3 (IQR 1.3-6.1) years. Survival probability at 5 years after HTx was 93%. Two patients underwent re-transplantation (one of them in an adult center). Significant rejection-free survival at 1, 3, and 6 years after HTx was 76%, 63%, and 63%, respectively. CONCLUSIONS: The introduced pediatric HTx program reflects the complexity of the treated population, with half of the patients having complex CHD and one-third being bridged to HTx by LVADs. Mid-term results are comparable to worldwide data. The data confirm the possibility of establishing a successful nationwide pediatric HTx program in a relatively small population country with well-developed pediatric cardiovascular care and other transplantation programs.
- Klíčová slova
- child, heart transplantation, nationwide, ventricular assist device,
- MeSH
- dítě MeSH
- dospělí MeSH
- kardiomyopatie * MeSH
- lidé MeSH
- podpůrné srdeční systémy * MeSH
- retrospektivní studie MeSH
- srdeční selhání * chirurgie MeSH
- transplantace srdce * MeSH
- vrozené srdeční vady * MeSH
- výsledek terapie MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- Geografické názvy
- Česká republika MeSH
- Klíčová slova
- adult, durable MCS, guideline, heart failure,
- MeSH
- lidé MeSH
- podpůrné srdeční systémy * MeSH
- srdce MeSH
- srdeční selhání * chirurgie MeSH
- transplantace plic * MeSH
- transplantace srdce * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- směrnice pro lékařskou praxi MeSH
- MeSH
- lidé MeSH
- podpůrné srdeční systémy * MeSH
- srdce MeSH
- srdeční selhání * chirurgie MeSH
- transplantace plic * MeSH
- transplantace srdce * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- směrnice pro lékařskou praxi MeSH
The Aeson total artificial heart (A-TAH) has been developed for patients at risk of death from biventricular failure. We aimed to assess the inflammatory status in nine subjects implanted with the A-TAH in kinetics over one year. Laboratory assessment of leukocyte counts, inflammatory cytokines assay, and peripheral blood mononuclear cell collection before and after A-TAH implantation. Leukocyte counts were not significantly modulated according to time after A-TAH implantation (coefficient of the linear mixed effect model with 95% CI, -0.05 (-0.71 to -0.61); p = 0.44). We explored inflammatory cytokine after A-TAH and did not observe, at any time, a modified profile compared to pre-implantation values (all p -values > 0.05). Finally, we compared the distribution of circulating immune cell subpopulations identified based on sequential expression patterns for multiple clusters of differentiation. None of the population explored had significant modulation during the 12-month follow-up (all p -values > 0.05). In conclusion, using a cytokine multiplex assay combined with a flow cytometry approach, we demonstrated the absence of inflammatory signals in peripheral blood over a period of 12 months following A-TAH implantation.
- MeSH
- cytokiny MeSH
- leukocyty mononukleární MeSH
- lidé MeSH
- srdeční selhání * chirurgie MeSH
- transplantace srdce * škodlivé účinky MeSH
- umělé srdce * škodlivé účinky MeSH
- zánět etiologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- cytokiny MeSH
OBJECTIVES: A third paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (<19 years of age) performed from 1 January 2000 to 31 December 2020 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS: Twenty-five hospitals contributed 537 registered implants in 480 patients. The most frequent aetiology of heart failure was any form of cardiomyopathy (59%), followed by congenital heart disease and myocarditis (15% and 14%, respectively). Competing outcomes analysis revealed that a total of 86% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 21.9% died while on support. At 12 months, 45.1% received transplants, 7.5% were weaned from their device and 20.8% died. The 3-month adverse events rate was 1.59 per patient-year for device malfunction including pump exchange, 0.7 for major bleeding, 0.78 for major infection and 0.71 for neurological events. CONCLUSIONS: The overall survival rate was 79.2% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age; P = 0.01) and lower weight (<20 kg; P = 0.015). Transplant rates at 6 months continue to be low (33.2%).
- Klíčová slova
- Congenital heart disease, End-stage heart failure, Mechanical circulatory support, Paediatric patients, Registry, Ventricular assist device,
- MeSH
- dítě MeSH
- hrudní chirurgické výkony * MeSH
- lidé MeSH
- podpůrné srdeční systémy * škodlivé účinky MeSH
- registrace MeSH
- retrospektivní studie MeSH
- srdeční selhání * epidemiologie etiologie chirurgie MeSH
- vrozené srdeční vady * epidemiologie chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: In the third report of the European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery, outcomes of patients receiving mechanical circulatory support are reviewed in relation to implant era. METHODS: Procedures in adult patients (January 2011-June 2020) were included. Patients from centres with <60% follow-ups completed were excluded. Outcomes were stratified into 3 eras (2011-2013, 2014-2017 and 2018-2020). Adverse event rates (AERs) were calculated and stratified into early phase (<3 months) and late phase (>3 months). Risk factors for death were explored using univariable Cox regression with a stepwise time-varying hazard ratio (<3 vs >3 months). RESULTS: In total, 4834 procedures in 4486 individual patients (72 hospitals) were included, with a median follow-up of 1.1 (interquartile range: 0.3-2.6) years. The annual number of implants (range: 346-600) did not significantly change (P = 0.41). Both Interagency Registry for Mechanically Assisted Circulatory Support class (classes 4-7: 23, 25 and 33%; P < 0.001) and in-hospital deaths (18.5, 17.2 and 11.2; P < 0.001) decreased significantly between eras. Overall, mortality, transplants and the probability of weaning were 55, 25 and 2% at 5 years after the implant, respectively. Major infections were mainly noted early after the implant occurred (AER<3 months: 1.44 vs AER>3 months: 0.45). Bilirubin and creatinine levels were significant risk factors in the early phase but not in the late phase after the implant. CONCLUSIONS: In its 10 years of existence, EUROMACS has become a point of reference enabling benchmarking and outcome monitoring. Patient characteristics and outcomes changed between implant eras. In addition, both occurrence of outcomes and risk factor weights are time dependent.
- Klíčová slova
- End-stage heart failure, Mechanical circulatory support, Registry, Ventricular assist device,
- MeSH
- dospělí MeSH
- hrudní chirurgické výkony * MeSH
- hrudní chirurgie * MeSH
- lidé MeSH
- podpůrné srdeční systémy * škodlivé účinky MeSH
- registrace MeSH
- srdeční selhání * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: We investigated the clinical outcomes after cardiac valvular surgery procedures concomitant (CCPs) with left ventricular assist device (LVAD) implantation compared to propensity score (PS) matched controls using the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) data. METHODS: Between 2006 and 2018, 2760 continuous-flow LVAD patients were identified. Of these, 533 underwent a CCP during the LVAD implant. RESULTS: Cardiopulmonary bypass time (p < 0.001) and time for implant (p < 0.001) were both significantly longer in the LVAD+CCP group. Hospital mortality was comparable between the two groups from the unmatched population (15.7% vs. 14.1%, p = 0.073). Similarly, short-to-mid-term survival was similar in both groups, with 1-year, 3-year, and 5-year survival rates of 67.9%, 48.2%, and 27.7% versus 66.4%, 46.1%, and 26%, respectively (log-rank, p = 0.25). The results were similar in the PS-matched population. Hospital mortality was comparable between the two groups (18.9% vs. 17.4%, p = 0.074). The short-to-mid-term Kaplan-Meier survival analysis was similar for both groups, with 1-year, 3-year, and 5-year survival rates of 63.4%, 49.2%, and 24.7% versus 66.5%, 46%, and 25.1%, respectively (log-rank, p = 0.81). In the unmatched population, LVAD+CCP patients had longer intensive care unit (ICU) stays (p < 0.0001), longer mechanical ventilation time (p = 0.001), a higher rate of temporary right ventricular assist device (RVAD) support (p = 0.033), and a higher rate of renal replacement therapy (n = 35, 6.6% vs. n = 89, 4.0%, p = 0.014). In the PS-matched population, the LVAD+CCP patients had longer ICU stays (p = 0.019) and longer mechanical ventilation time (p = 0.002). CONCLUSIONS: The effect of additive valvular procedures (CCPs) does not seem to affect short-term survival, significantly, based on our registry data analysis. However, the decision to perform CCPs should be balanced with the projected type of surgery and preoperative characteristics. LVAD+CCP patients remain a delicate population and adverse device-related events should be strictly monitored and managed.
- Klíčová slova
- concomitant cardiac surgery, heart failure, left ventricular assist device, registry,
- MeSH
- lidé MeSH
- podpůrné srdeční systémy * škodlivé účinky MeSH
- registrace MeSH
- retrospektivní studie MeSH
- srdeční selhání * epidemiologie chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
We herein present a case study of a patient with heart failure with a preserved ejection fraction and severe symptoms who underwent interatrial shunt device implantation and follow-up at a tertiary care heart failure clinic. The interatrial shunt device implantation was successful. No adverse events occurred, and the device prevented hospitalization for heart failure during long-term follow-up.
- Klíčová slova
- Heart failure with preserved ejection fraction, adverse outcomes, case report, hospitalization for heart failure, interatrial shunt device, long-term follow-up,
- MeSH
- lidé MeSH
- následné studie MeSH
- srdeční katetrizace MeSH
- srdeční selhání * chirurgie MeSH
- srdeční síně * chirurgie MeSH
- tepový objem MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Despite recent advances in management of patients with advanced heart failure, mortality remains high. Aim of this study was to compare impact of different aetiology of ischaemic and idiopathic cardiomyopathy on early outcomes and long-term survival of patients after left ventricular assist device implantation. METHODS: European Registry for Patients with Mechanical Circulatory Support (EUROMACS) gathers clinical data and follow-up parameters of LVAD recipients. Patients enrolled in the EUROMACS registry with primary diagnosis of either ischaemic (n = 1190) or idiopathic (n = 812) cardiomyopathy were included. Primary Endpoints were early mortality as well as long-term survival. Secondary endpoint were major postoperative adverse events, such as need for rethoracotomy. Additionally, a propensity-score matching analysis was performed for patients with ischaemic (n = 509) and idiopathic (n = 509) cardiomyopathy. RESULTS: In terms of basic demographics and baseline parameters the two groups significantly differed as expected before propensity-score matching due to different aetiology of cardiomyopathy. Seven-day (52 (4.4%) versus 18 (2.2%); p = 0.009), 30-day (153 (12.9%) versus 73 (9.0%); p = 0.008) and in-hospital mortality (253 (19.7%) versus 123 (15.1%); p = 0.009) were significantly lower in the idiopathic cardiomyopathy group compared to the ischaemic cardiomyopathy group, whereas after propensity-score matching 30-day (p = 0.169) was comparable and in-hospital mortality (p = 0.051) was almost significant. Kaplan-Meier survival analysis revealed no significant difference in regard of long-term survival after propensity-score matching (Breslow-test p = 0.161 and LogRank-test p = 0.113). CONCLUSION: Though patients with ischaemic and idiopathic cardiomyopathy suffer from different cardiomyopathy aetiologies, 30-day-mortality and long-term survival of both groups were similar leading to the conclusion that covariates predominately influence mortality and survival of ischaemic and idiopathic cardiomyopathies.
- Klíčová slova
- EUROMACS, LVAD, cardiomyopathy, outcome, survival,
- MeSH
- kardiomyopatie * etiologie MeSH
- lidé MeSH
- podpůrné srdeční systémy * škodlivé účinky MeSH
- retrospektivní studie MeSH
- srdeční selhání * chirurgie MeSH
- tendenční skóre MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
The CARMAT-Total Artificial Heart (C-TAH) is designed to provide heart replacement therapy for patients with end-stage biventricular failure. This report details the reliability and efficacy of the autoregulation device control mechanism (auto-mode), designed to mimic normal physiologic responses to changing patient needs. Hemodynamic data from a continuous cohort of 10 patients implanted with the device, recorded over 1,842 support days in auto-mode, were analyzed with respect to daily changing physiologic needs. The C-TAH uses embedded pressure sensors to regulate the pump output. Right and left ventricular outputs are automatically balanced. The operator sets target values and the inbuilt algorithm adjusts the stroke volume and beat rate, and hence cardiac output, automatically. Auto-mode is set perioperatively after initial postcardiopulmonary bypass hemodynamic stabilization. All patients showed a range of average inflow pressures of between 5 and 20 mm Hg during their daily activities, resulting in cardiac output responses of between 4.3 and 7.3 L/min. Operator adjustments were cumulatively only required on 20 occasions. This report demonstrates that the C-TAH auto-mode effectively produces appropriate physiologic responses reflective of changing patients' daily needs and represents one of the unique characteristics of this device in providing almost physiologic heart replacement therapy.
- MeSH
- hemodynamika MeSH
- homeostáza MeSH
- krevní tlak MeSH
- lidé MeSH
- reprodukovatelnost výsledků MeSH
- srdeční selhání * chirurgie MeSH
- umělé srdce * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH