Nejvíce citovaný článek - PubMed ID 21843353
Blood pressure (BP) is one of the most important variables evaluated during almost every medical examination. Most national anesthesiology societies recommend BP monitoring at least once every 5 min in anesthetized subjects undergoing surgical procedures. In most cases, BP is monitored non-invasively using oscillometric cuffs. Although the risk of arterial cannulation is not very high, the invasive BP monitoring is usually indicated only in the case of high-risk patients or in complex surgical procedures. However, recent evidence points out that when using intermittent BP monitoring short periods of hypotension may be overlooked. In addition, large datasets have demonstrated that even short periods of low BP (or their cumulative duration) may have a detrimental impact on the development of postoperative outcome including increased risk of acute kidney or myocardial injury development. Recently marketed continuous non-invasive blood pressure monitoring tools may help us to recognize the BP fluctuation without the associated burden of arterial cannulation filling the gap between intermittent non-invasive cuff and continuous invasive arterial pressure. Among others, several novel devices based either on volume clamp/vascular unloading method or on applanation tonometry are nowadays available. Moreover, several near-future smart technologies may lead to better hypotension recognition or even prediction potentially improving our ability to maintain BP stability throughout the anesthesia or surgical procedure. In this review, novel or emerging technologies of non-invasive continuous blood pressure assessment and their potential to improve postoperative outcome are discussed.
Fluid therapy is still the mainstay of acute care in patients with shock or cardiovascular compromise. However, our understanding of the critically ill pathophysiology has evolved significantly in recent years. The revelation of the glycocalyx layer and subsequent research has redefined the basics of fluids behavior in the circulation. Using less invasive hemodynamic monitoring tools enables us to assess the cardiovascular function in a dynamic perspective. This allows pinpointing even distinct changes induced by treatment, by postural changes, or by interorgan interactions in real time and enables individualized patient management. Regarding fluids as drugs of any other kind led to the need for precise indication, way of administration, and also assessment of side effects. We possess now the evidence that patient centered outcomes may be altered when incorrect time, dose, or type of fluids are administered. In this review, three major features of fluid therapy are discussed: the prediction of fluid responsiveness, potential harms induced by overzealous fluid administration, and finally the problem of protocol-led treatments and their timing.
- MeSH
- hemodynamika * MeSH
- kardiovaskulární nemoci * patofyziologie terapie MeSH
- lidé MeSH
- monitorování fyziologických funkcí * MeSH
- péče o pacienty v kritickém stavu metody MeSH
- šok * patofyziologie terapie MeSH
- tekutinová terapie * škodlivé účinky metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
BACKGROUND: The use of goal directed fluid protocols in intermediate risk patients undergoing hip or knee replacement was studied in few trials using invasive monitoring. For this reason we have implemented two different fluid management protocols, both based on a novel totally non-invasive arterial pressure monitoring device and compared them to the standard (no-protocol) treatment applied before the transition in our academic institution. METHODS: Three treatment groups were compared in this prospective study: the observational (CONTROL, N = 40) group before adoption of fluid protocols and two randomized groups after the transition to protocol fluid management with the use of the continuous non-invasive blood pressure monitoring (CNAP®) device. In the PRESSURE group (N = 40) standard variables were used for restrictive fluid therapy. Goal directed fluid therapy using pulse pressure variation was used in the GDFT arm (N = 40). The influence on the rate of postoperative complications, on the hospital length of stay and other parameters was assessed. RESULTS: Both protocols were associated with decreased fluid administration and maintained hemodynamic stability. Reduced rate of postoperative infection and organ complications (22 (55 %) vs. 33 (83 %) patients; p = 0.016; relative risk 0.67 (0.49-0.91)) was observed in the GDFT group compared to CONTROL. Lower number of patients receiving transfusion (4 (10 %) in GDFT vs. 17 (43 %) in CONTROL; p = 0.005) might contribute to this observation. No significant differences were observed in other end-points. CONCLUSION: In our study, the use of the fluid protocol based on pulse pressure variation assessed using continuous non-invasive arterial pressure measurement seems to be associated with a reduction in postoperative complications and transfusion needs as compared to standard no-protocol treatment. TRIAL REGISTRATION: ACTRN12612001014842.
- MeSH
- arteriální tlak fyziologie MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhrada kyčelního kloubu škodlivé účinky metody MeSH
- peroperační monitorování škodlivé účinky metody MeSH
- pooperační komplikace diagnóza etiologie prevence a kontrola MeSH
- prospektivní studie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- tekutinová terapie metody MeSH
- totální endoprotéza kolene škodlivé účinky metody MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
Intermittent blood pressure (BP) monitoring is the standard-of-care during low and intermediate risk anaesthesia, yet it could lead to delayed recognition of BP fluctuations. Perioperative hypotension is known to be associated with postoperative complications. Continuous, non-invasive methods for BP monitoring have been developed recently. We have tested a novel non-invasive, continuous monitor (using the volume clamp method) to assist with maintaining BP in safe ranges for patients undergoing surgery in a beach chair position. Forty adult patients undergoing thyroid gland surgery in an upright position were included in this prospective randomised controlled trial. Patients were equally allocated to the group with continuous monitoring of BP using the CNAP® Monitor and to the control group managed using an intermittent oscillometric BP cuff. The absolute and proportional time spent outside the range of ±20% of the target BP along with other hemodynamic and clinical parameters were evaluated. The continuous monitoring decreased the anaesthesia time spent below -20% pressure range [absolute: 12 min (4-20) vs. 27 min (16-34); p=0.001; relative to procedure length: 14% (7-20) vs. 33.5% (17.5-53); p=0.003]. No significant differences were observed in postoperative morbidity or in hospital length of stay. Continuous non-invasive BP monitoring via the CNAP® Monitor allows for better BP management in patients undergoing surgery in a beach chair position. In our randomised trial the time spent in hypotension was significantly shorter using continuous monitoring.
- MeSH
- anestezie metody MeSH
- anesteziologie MeSH
- dospělí MeSH
- hypotenze patofyziologie prevence a kontrola MeSH
- katetrizace MeSH
- krevní tlak * MeSH
- lidé středního věku MeSH
- lidé MeSH
- měření krevního tlaku metody MeSH
- monitorování fyziologických funkcí MeSH
- monitory krevního tlaku MeSH
- oscilometrie MeSH
- peroperační monitorování metody MeSH
- polohování pacienta MeSH
- prospektivní studie MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
BACKGROUND: Perioperative goal directed therapy (GDT) can substantially improve the outcomes of high risk surgical patients as shown by many clinical studies. However, the approach needs initial investment and can increase the already very high staff workload. These economic imperatives may be at least partly responsible for weak adherence to the GDT concept. A few models are available for the evaluation of GDT cost-effectiveness, but studies of real economic data based on a recent clinical trial are lacking. In order to address this we have performed a retrospective analysis of the data from the "Intraoperative fluid optimization using stroke volume variation in high risk surgical patients" trial (ISRCTN95085011). METHODS: The health-care payers perspective was used in order to evaluate the perioperative hemodynamic optimization costs. Hospital invoices from all patients included in the trial were extracted. A direct comparison between the study (GDT, N = 60) and control (N = 60) groups was performed. A cost tree was constructed and major cost drivers evaluated. RESULTS: The trial showed a significant improvement in clinical outcomes for GDT treated patients. The mean cost per patient were lower in the GDT group 2877 ± 2336€ vs. 3371 ± 3238€ in controls, but without reaching a statistical significance (p = 0.596). The mean cost of all items except for intraoperative monitoring and infusions were lower for GDT than control but due to the high variability they all failed to reach statistical significance. Those costs associated with clinical care (68 ± 177€ vs. 212 ± 593€; p = 0.023) and ward stay costs (213 ± 108€ vs. 349 ± 467€; p = 0.082) were the most important differences in favour of the GDT group. CONCLUSIONS: Intraoperative fluid optimization with the use of stroke volume variation and Vigileo/FloTrac system showed not only a substantial improvement of morbidity, but was associated with an economic benefit. The cost-savings observed in the overall costs of postoperative care trend to offset the investment needed to run the GDT strategy and intraoperative monitoring. TRIAL REGISTRATION: ISRCTN95085011.
- Klíčová slova
- Cost-effectiveness, Fluid optimization, Hemodynamic optimization,
- MeSH
- analýza nákladů a výnosů MeSH
- hemodynamika * MeSH
- lidé MeSH
- náklady a analýza nákladů MeSH
- perioperační péče ekonomika metody MeSH
- peroperační monitorování ekonomika metody MeSH
- peroperační péče ekonomika metody MeSH
- retrospektivní studie MeSH
- tekutinová terapie ekonomika metody MeSH
- tepový objem * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH