Nejvíce citovaný článek - PubMed ID 24963567
This study aimed to evaluate the ability of selected microRNAs as biomarkers of atrial fibrillation (AF) in ischemic stroke patients in comparison with other established biochemical biomarkers. A prospective case-control study of consecutive ischemic stroke patients with AF admitted to a comprehensive stroke center was conducted. The control group consisted of patients with ischemic stroke with no AF detected on prolonged (at least 3 weeks) Holter ECG monitoring. As potential biomarkers of AF, we analyzed the plasma levels of microRNAs (miR-21, miR-29b, miR-133b, miR-142-5p, miR-150, miR-499, and miR-223-3p) and 13 biochemical biomarkers at admission. The predictive accuracy of biomarkers was assessed by calculating the area under the receiver operating characteristic curve. The data of 117 patients were analyzed (61 with AF, 56 with no AF, 46% men, median age 73 years, median National Institutes of Health Stroke Scale 6). Biochemical biomarkers (N-terminal pro-B-type natriuretic peptide [NT-proBNP], high-sensitivity cardiac troponin I, fibrinogen, C-reactive protein, eGFR, and total triglycerides) were significantly associated with AF. NT-proBNP had the best diagnostic performance for AF with area under the receiver operating characteristic curve 0.92 (95%, CI 0.86-0.98); a cutoff value of >528 ng/L had a sensitivity of 79% and a specificity of 97%. None of the other biomarkers, including microRNAs, was associated with AF. Conventional biochemical biomarkers (NT-proBNP, high-sensitivity cardiac troponin I, fibrinogen, C-reactive protein, eGFR, and triglycerides), but not microRNAs (miR-21, miR-29b, miR-133b, miR-142-5p, miR-150, miR-499, and miR-223-3p) were significantly associated with AF in our ischemic stroke cohort.
- MeSH
- biologické markery * krev MeSH
- C-reaktivní protein analýza MeSH
- fibrilace síní * krev diagnóza genetika MeSH
- ischemická cévní mozková příhoda * krev diagnóza MeSH
- lidé středního věku MeSH
- lidé MeSH
- mikro RNA * krev MeSH
- natriuretický peptid typu B krev MeSH
- peptidové fragmenty krev MeSH
- prospektivní studie MeSH
- ROC křivka MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- studie případů a kontrol MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- Názvy látek
- biologické markery * MeSH
- C-reaktivní protein MeSH
- mikro RNA * MeSH
- natriuretický peptid typu B MeSH
- peptidové fragmenty MeSH
- pro-brain natriuretic peptide (1-76) MeSH Prohlížeč
BACKGROUND: Short and rare episodes of atrial fibrillation (AF) are commonly detected using implanted devices (device-detected AF) in patients with prior stroke or transient ischemic attack (TIA). The effectiveness and safety of oral anticoagulation in patients with prior stroke or TIA and device-detected AF but with no ECG-documented AF is unclear. METHODS AND RESULTS: This prespecified analysis of the NOAH-AFNET 6 (Non-Vitamin K Antagonist Oral Anticoagulants in Patients With Atrial High Rate Episodes) trial with post hoc elements assessed the effect of oral anticoagulation in patients with device-detected AF with and without a prior stroke or TIA in the randomized, double-blind, double-dummy NOAH-AFNET 6 trial. Outcomes were stroke, systemic embolism, and cardiovascular death (primary outcome) and major bleeding and death (safety outcome). A prior stroke or TIA was found in 253 patients with device-detected AF randomized in the NOAH-AFNET 6 (mean age, 78 years; 36.4% women). There was no treatment interaction with prior stroke or TIA for any of the primary and secondary time-to-event outcomes. In patients with a prior stroke or TIA, 14 out of 122 patients experienced a primary outcome event with anticoagulation (5.7% per patient-year). Without anticoagulation, there were 16 out of 131 patients with an event (6.3% per patient-year). The rate of stroke was lower than expected (anticoagulation: 4 out of 122 [1.6% per patient-year]; no anticoagulation: 6 out of 131 [2.3% per patient-year]). Numerically, there were more major bleeding events with anticoagulation in patients with prior stroke or TIA (8 out of 122 patients) than without anticoagulation (2 out of 131 patients). CONCLUSIONS: Anticoagulation appears to have ambiguous effects in patients with device-detected AF and a prior stroke or TIA in this hypothesis-generating analysis of the NOAH-AFNET 6 in the absence of ECG-documented AF, partially due to a low rate of stroke without anticoagulation.
- Klíčová slova
- CHA2DS2‐VASc score, NOAH‐AFNET 6, anticoagulation, atrial fibrillation, device‐detected atrial fibrillation, recurrent stroke,
- MeSH
- antikoagulancia * aplikace a dávkování škodlivé účinky terapeutické užití MeSH
- aplikace orální MeSH
- časové faktory MeSH
- cévní mozková příhoda * prevence a kontrola etiologie MeSH
- dvojitá slepá metoda MeSH
- fibrilace síní * farmakoterapie komplikace diagnóza MeSH
- kardiostimulátor MeSH
- krvácení chemicky indukované MeSH
- lidé MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- tranzitorní ischemická ataka * prevence a kontrola etiologie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
- Názvy látek
- antikoagulancia * MeSH
Atrial high-rate episodes (AHRE) are atrial tachyarrhythmias detected by continuous rhythm monitoring by pacemakers, defibrillators, or implantable cardiac monitors. Atrial high-rate episodes occur in 10-30% of elderly patients without atrial fibrillation. However, it remains unclear whether the presence of these arrhythmias has therapeutic consequences. The presence of AHRE increases the risk of stroke compared with patients without AHRE. Oral anticoagulation would have the potential to reduce the risk of stroke in patients with AHRE but is also associated with a rate of major bleeding of ∼2%/year. The stroke rate in patients with AHRE appears to be lower than the stroke rate in patients with atrial fibrillation. Wearables like smart-watches will increase the absolute number of patients in whom atrial arrhythmias are detected. It remains unclear whether anticoagulation is effective and, equally important, safe in patients with AHRE. Two randomized clinical trials, NOAH-AFNET6 and ARTESiA, are expected to report soon. They will provide much-needed information on the efficacy and safety of oral anticoagulation in patients with AHRE.
- Klíčová slova
- Anticoagulation, Atrial fibrillation, Atrial high-rate episodes, Continuous monitoring, Implantable cardiac monitor, Pacemaker, Stroke, Sub-clinical atrial fibrillation, Thrombo-embolic risk,
- MeSH
- antikoagulancia terapeutické užití MeSH
- cévní mozková příhoda * diagnóza etiologie prevence a kontrola MeSH
- fibrilace síní * komplikace diagnóza farmakoterapie MeSH
- lidé MeSH
- rizikové faktory MeSH
- senioři MeSH
- srdeční síně MeSH
- Check Tag
- lidé MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- antikoagulancia MeSH
- Klíčová slova
- AF populations at risk, AF screening, AF screening devices, Asymptomatic atrial fibrillation, Atrial fibrillation, Patient’s benefits of AF screening,
- MeSH
- cévní mozková příhoda * MeSH
- fibrilace síní * diagnóza terapie MeSH
- lidé MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Inflammation contributes to unstable atherosclerotic plaque and stroke. In randomised trials in patients with coronary disease, canukinumab (an interleukin-1B antagonist) and colchicine (a tubulin inhibitor with pleiotropic anti-inflammatory effects) reduced recurrent vascular events.Hypothesis: Anti-inflammatory therapy with low-dose colchicine plus usual care will reduce recurrent vascular events in patients with non-severe, non-cardioembolic stroke and TIA compared with usual care alone. DESIGN: CONVINCE is a multi-centre international (in 17 countries) Prospective, Randomised Open-label, Blinded-Endpoint assessment (PROBE) controlled Phase 3 clinical trial in 3154 participants. The intervention is colchicine 0.5 mg/day and usual care versus usual care alone (antiplatelet, lipid-lowering, antihypertensive treatment, lifestyle advice). Included patients are at least 40 years, with non-severe ischaemic stroke (modified Rankin score ≤3) or high-risk TIA (ABCD2 > 3, or positive DWI, or cranio-cervical artery stenosis) within 72 hours-28 days of randomisation, with qualifying stroke/TIA most likely caused by large artery stenosis, lacunar disease, or cryptogenic embolism. Exclusions are stroke/TIA caused by cardio-embolism or other defined cause (e.g. dissection), contra-indication to colchicine (including potential drug interactions), or incapacity for participation in a clinical trial. The anticipated median follow-up will be 36 months. The primary analysis will be by intention-to-treat. OUTCOME: The primary outcome is time to first recurrent ischaemic stroke, myocardial infarction, cardiac arrest, or hospitalisation with unstable angina (non-fatal or fatal). SUMMARY: CONVINCE will provide high-quality randomised data on the efficacy and safety of anti-inflammatory therapy with colchicine for secondary prevention after stroke. SCHEDULE: First-patient first-visit was December 2016. Recruitment to complete in 2021, follow-up to complete in 2023.
- Klíčová slova
- Ischaemic stroke, colchicine, inflammation, randomised controlled trial,
- Publikační typ
- časopisecké články MeSH
- MeSH
- hodnocení rizik MeSH
- konsensus MeSH
- lidé MeSH
- srdeční arytmie * diagnóza terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Asie MeSH
- Latinská Amerika MeSH
Self-terminating atrial arrhythmias are commonly detected on continuous rhythm monitoring, e.g. by pacemakers or defibrillators. It is unclear whether the presence of these arrhythmias has therapeutic consequences. We sought to summarize evidence on the prevalence of atrial high-rate episodes (AHREs) and their impact on risk of stroke. We performed a comprehensive, tabulated review of published literature on the prevalence of AHRE. In patients with AHRE, but without atrial fibrillation (AF), we reviewed the stroke risk and the potential risk/benefit of oral anticoagulation. Atrial high-rate episodes are found in 10-30% of AF-free patients. Presence of AHRE slightly increases stroke risk (0.8% to 1%/year) compared with patients without AHRE. Atrial high-rate episode of longer duration (e.g. those >24 h) could be associated with a higher stroke risk. Oral anticoagulation has the potential to reduce stroke risk in patients with AHRE but is associated with a rate of major bleeding of 2%/year. Oral anticoagulation is not effective in patients with heart failure or survivors of a stroke without AF. It remains unclear whether anticoagulation is effective and safe in patients with AHRE. Atrial high-rate episodes are common and confer a slight increase in stroke risk. There is true equipoise on the best way to reduce stroke risk in patients with AHRE. Two ongoing trials (NOAH-AFNET 6 and ARTESiA) will provide much-needed information on the effectiveness and safety of oral anticoagulation using non-vitamin K antagonist oral anticoagulants in patients with AHRE.
- Klíčová slova
- Anticoagulation, Atrial fibrillation, Atrial high-rate episodes, Continuous monitoring, Pacemaker, Stroke,
- MeSH
- antikoagulancia terapeutické užití MeSH
- celosvětové zdraví MeSH
- cévní mozková příhoda epidemiologie etiologie prevence a kontrola MeSH
- fibrilace síní komplikace farmakoterapie epidemiologie MeSH
- hodnocení rizik metody MeSH
- lidé MeSH
- prevalence MeSH
- rizikové faktory MeSH
- srdeční frekvence fyziologie MeSH
- srdeční síně patofyziologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
- Názvy látek
- antikoagulancia MeSH
IMPORTANCE: The NAVIGATE ESUS randomized clinical trial found that 15 mg of rivaroxaban per day does not reduce stroke compared with aspirin in patients with embolic stroke of undetermined source (ESUS); however, it substantially reduces stroke risk in patients with atrial fibrillation (AF). OBJECTIVE: To analyze whether rivaroxaban is associated with a reduction of recurrent stroke among patients with ESUS who have an increased risk of AF. DESIGN, SETTING, AND PARTICIPANTS: Participants were stratified by predictors of AF, including left atrial diameter, frequency of premature atrial contractions, and HAVOC score, a validated scheme using clinical features. Treatment interactions with these predictors were assessed. Participants were enrolled between December 2014 and September 2017, and analysis began March 2018. INTERVENTION: Rivaroxaban treatment vs aspirin. MAIN OUTCOMES AND MEASURES: Risk of ischemic stroke. RESULTS: Among 7112 patients with a mean (SD) age of 67 (9.8) years, the mean (SD) HAVOC score was 2.6 (1.8), the mean (SD) left atrial diameter was 3.8 (1.4) cm (n = 4022), and the median (interquartile range) daily frequency of premature atrial contractions was 48 (13-222). Detection of AF during follow-up increased for each tertile of HAVOC score: 2.3% (score, 0-2), 3.0% (score, 3), and 5.8% (score, >3); however, neither tertiles of the HAVOC score nor premature atrial contractions frequency impacted the association of rivaroxaban with recurrent ischemic stroke (P for interaction = .67 and .96, respectively). Atrial fibrillation annual incidence increased for each tertile of left atrial diameter (2.0%, 3.6%, and 5.2%) and for each tertile of premature atrial contractions frequency (1.3%, 2.9%, and 7.0%). Among the predefined subgroup of patients with a left atrial diameter of more than 4.6 cm (9% of overall population), the risk of ischemic stroke was lower among the rivaroxaban group (1.7% per year) compared with the aspirin group (6.5% per year) (hazard ratio, 0.26; 95% CI, 0.07-0.94; P for interaction = .02). CONCLUSIONS AND RELEVANCE: The HAVOC score, left atrial diameter, and premature atrial contraction frequency predicted subsequent clinical AF. Rivaroxaban was associated with a reduced risk of recurrent stroke among patients with ESUS and moderate or severe left atrial enlargement; however, this needs to be independently confirmed before influencing clinical practice.
- MeSH
- Aspirin terapeutické užití MeSH
- cévní mozková příhoda farmakoterapie MeSH
- fibrilace síní MeSH
- inhibitory agregace trombocytů terapeutické užití MeSH
- inhibitory faktoru Xa terapeutické užití MeSH
- intrakraniální embolie farmakoterapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- recidiva MeSH
- rivaroxaban terapeutické užití MeSH
- rizikové faktory MeSH
- sekundární prevence MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH
- Názvy látek
- Aspirin MeSH
- inhibitory agregace trombocytů MeSH
- inhibitory faktoru Xa MeSH
- rivaroxaban MeSH
INTRODUCTION: We conducted this study to show the safety and efficacy of a new implantable cardiac monitor (ICM), the BioMonitor 2 (Biotronik SE & Co. KG; Berlin, Germany), and to describe the arrhythmia detection performance. METHODS: The BioMonitor 2 has an extended sensing vector and is implanted close to the heart. It can transmit up to six subcutaneous electrocardiogram strips by Home Monitoring each day. We enrolled 92 patients with a standard device indication for an ICM in a single-arm, multicenter prospective trial. Patients were followed for 3 months, and 48-h Holter recordings were used to evaluate the arrhythmia detection performance. RESULTS: One patient withdrew consent and in one patient, the implantation failed. Two study device-related serious adverse events were reported, satisfying the primary safety hypothesis. Implantations took 7.4 ± 4.4 min from skin cut to suture. At 1 week, the R-wave amplitude was 0.75 ± 0.53 mV. In the 82 patients with completed Holter recordings, all patients with arrhythmias were correctly identified. False positive detections of arrhythmia were mostly irregular rhythms wrongly detected as atrial fibrillation (episode-based positive predictive value 72.5%). Daily Home Monitoring transmission was 94.9% successful. CONCLUSION: Safety and efficacy of the new device has been demonstrated. The detected R-wave amplitudes are large, leading to a low level of inappropriate detections due to over- or undersensing.
- Klíčová slova
- arrhythmia detection, atrial fibrillation, implantable cardiac monitor, remote monitoring, syncope,
- MeSH
- design vybavení MeSH
- elektrokardiografie ambulantní přístrojové vybavení MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- srdeční arytmie diagnóza MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- multicentrická studie MeSH
BACKGROUND: Embolic strokes of undetermined source comprise up to 20% of ischemic strokes. The stroke recurrence rate is substantial with aspirin, widely used for secondary prevention. The New Approach riVaroxaban Inhibition of Factor Xa in a Global trial versus ASA to prevenT Embolism in Embolic Stroke of Undetermined Source international trial will compare the efficacy and safety of rivaroxaban, an oral factor Xa inhibitor, versus aspirin for secondary prevention in patients with recent embolic strokes of undetermined source. MAIN HYPOTHESIS: In patients with recent embolic strokes of undetermined source, rivaroxaban 15 mg once daily will reduce the risk of recurrent stroke (both ischemic and hemorrhagic) and systemic embolism (primary efficacy outcome) compared with aspirin 100 mg once daily. DESIGN: Double-blind, randomized trial in patients with embolic strokes of undetermined source, defined as nonlacunar cryptogenic ischemic stroke, enrolled between seven days and six months from the qualifying stroke. The planned sample size of 7000 participants will be recruited from approximately 480 sites in 31 countries between 2014 and 2017 and followed for a mean of about two years until at least 450 primary efficacy outcome events have occurred. The primary safety outcome is major bleeding. Two substudies assess (1) the relative effect of treatments on MRI-determined covert brain infarcts and (2) the biological underpinnings of embolic strokes of undetermined source using genomic and biomarker approaches. SUMMARY: The New Approach riVaroxaban Inhibition of Factor Xa in a Global trial versus ASA to prevenT Embolism in Embolic Stroke of Undetermined Source trial is evaluating the benefits and risks of rivaroxaban for secondary stroke prevention in embolic strokes of undetermined source patients. Main results are anticipated in 2018.
- Klíčová slova
- Stroke, aspirin, cerebral embolism, cryptogenic stroke, embolic stroke of undetermined source, randomized trial, rivaroxaban, stroke prevention,
- Publikační typ
- časopisecké články MeSH