Most cited article - PubMed ID 31085321
Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial Fibrillation
BACKGROUND: Deep analgosedation (DAS) or general anesthesia is mandatory for pulsed-field ablation of atrial fibrillation. In contrast to DAS, general anesthesia (conventional or total intravenous anesthesia [TIVA]) requires airway management. To find the optimal sedation regimen, this study compared ketamine-remimazolam DAS and propofol-opioid TIVA with propofol-opioid DAS, focusing on sedation-related adverse events. METHODS: Patients indicated for atrial fibrillation catheter ablation were randomly assigned at a 1:1:1 ratio to: (1) DAS using intermittent propofol-opioid boluses (arm P), (2) continuous remimazolam-ketamine DAS (arm R), or (3) continuous propofol-opioid TIVA with secured airway (arm TIVA). Catheter ablation was performed using the FARAPULSE system (Boston Scientific, MA). The major exclusion criterion was obstructive sleep apnea syndrome. The primary end point was defined as a composite of hypoxemia, hypotensive, or hypertensive events requiring intervention or leading to procedure discontinuation. Secondary end points included hemodynamic instability events, procedure time, serious adverse events, and patient satisfaction. RESULTS: One-hundred twenty-seven patients (mean age 62.9±10.3 years, 35.1% women, 47.2% with paroxysmal atrial fibrillation) were enrolled and randomized to the P (n=42), R (n=43), or TIVA (n=42) arms. The primary end point occurred in 85.7% of P patients, 27.9% of R patients, and 66.7% of TIVA patients (P<0.001), driven by hypoxemia in the P arm (100% of patients with the primary end point) and by hypotension in the TIVA arm (100%). The R arm showed a similar distribution of hypoxemia (50%) and hypotensive (66.7%) events. No differences were observed in mean procedural time, rate of serious adverse events, and assessment of patient satisfaction. CONCLUSIONS: In pulsed-field ablation procedures for atrial fibrillation, remimazolam-ketamine DAS was superior to propofol-opioid regimens (either boluses or continuous) and had the lowest risk of hypoxemia and hypotensive events. More than 80% of patients undergoing conventional propofol-opioid analgosedation experienced hypoxemia. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT06013345.
- Keywords
- atrial fibrillation, catheter ablation, deep sedation, general anesthesia,
- MeSH
- Anesthetics, Intravenous administration & dosage adverse effects MeSH
- Anesthesia, General methods adverse effects MeSH
- Atrial Fibrillation * surgery physiopathology diagnosis MeSH
- Deep Sedation * methods adverse effects MeSH
- Hypnotics and Sedatives administration & dosage adverse effects MeSH
- Catheter Ablation * methods adverse effects MeSH
- Ketamine * administration & dosage adverse effects MeSH
- Middle Aged MeSH
- Humans MeSH
- Analgesics, Opioid administration & dosage adverse effects MeSH
- Propofol * administration & dosage adverse effects MeSH
- Aged MeSH
- Treatment Outcome MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Randomized Controlled Trial MeSH
- Comparative Study MeSH
- Names of Substances
- Anesthetics, Intravenous MeSH
- Hypnotics and Sedatives MeSH
- Ketamine * MeSH
- Analgesics, Opioid MeSH
- Propofol * MeSH
Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.
- MeSH
- Atrial Fibrillation * surgery therapy MeSH
- Catheter Ablation * adverse effects methods MeSH
- Middle Aged MeSH
- Humans MeSH
- Postoperative Complications epidemiology etiology MeSH
- Aged MeSH
- Treatment Outcome MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Multicenter Study MeSH
AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.
- Keywords
- Atrial fibrillation, Catheter ablation, Pulmonary vein isolation, Pulsed field ablation, Radiofrequency current, Randomized trial,
- MeSH
- Atrial Fibrillation * surgery physiopathology diagnosis therapy MeSH
- Catheter Ablation * methods MeSH
- Middle Aged MeSH
- Humans MeSH
- Recurrence MeSH
- Pulmonary Veins surgery MeSH
- Treatment Outcome MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Multicenter Study MeSH
- Clinical Trial Protocol MeSH
- Comparative Study MeSH
- Geographicals
- Europe MeSH
BACKGROUND: We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study's conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success. METHODS: InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success. RESULTS: The patient cohort included 186 patients: aged 59±10 years, female 30%, and CHA2DS2-VASc 1.3±1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%-81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%-87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%-90.9%) or 94.0% (95% CI, 90.6%-97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction ≥60% (adjusted odds ratio, 0.30) and patients receiving ≥48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received ≥12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications. CONCLUSIONS: The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (≥48 total or ≥12 per vein) resulted in an improved 1-year success rate of ≈80%. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04524364.
- Keywords
- atrial fibrillation, catheters, electroporation, pulmonary veins,
- MeSH
- Action Potentials MeSH
- Time Factors MeSH
- Equipment Design MeSH
- Electrophysiologic Techniques, Cardiac MeSH
- Electrocardiography, Ambulatory instrumentation MeSH
- Atrial Fibrillation * surgery physiopathology diagnosis MeSH
- Catheter Ablation * instrumentation methods adverse effects MeSH
- Middle Aged MeSH
- Humans MeSH
- Predictive Value of Tests MeSH
- Prospective Studies MeSH
- Recurrence MeSH
- Risk Factors MeSH
- Aged MeSH
- Heart Rate MeSH
- Cardiac Catheters MeSH
- Pulmonary Veins * surgery physiopathology MeSH
- Treatment Outcome MeSH
- Imaging, Three-Dimensional MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Clinical Trial MeSH
- Multicenter Study MeSH
AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.
- Keywords
- Atrial fibrillation, Catheter ablation, Electroanatomical mapping system, Lesion durability, Pulsed field ablation, Single-shot,
- MeSH
- Action Potentials MeSH
- Time Factors MeSH
- Equipment Design MeSH
- Electrophysiologic Techniques, Cardiac MeSH
- Atrial Fibrillation * surgery physiopathology diagnosis MeSH
- Catheter Ablation * methods instrumentation MeSH
- Middle Aged MeSH
- Humans MeSH
- Recurrence * MeSH
- Aged MeSH
- Heart Rate MeSH
- Cardiac Catheters * MeSH
- Pulmonary Veins * surgery MeSH
- Treatment Outcome MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Clinical Trial MeSH
- Multicenter Study MeSH
- Research Support, Non-U.S. Gov't MeSH
IMPORTANCE: Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile. OBJECTIVE: To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry. DESIGN, SETTING, AND PARTICIPANTS: This was a retrospective cohort study of MANIFEST-PF registry data, which included consecutive patients undergoing postregulatory approval treatment with PFA to treat AF between March 2021 and May 2022 with a median follow-up of 1 year. MANIFEST-PF is a multinational, retrospectively analyzed, prospectively enrolled patient-level registry including 24 European centers. The study included all consecutive registry patients (age ≥18 years) who underwent first-ever PFA for paroxysmal or persistent AF. EXPOSURE: PFA was performed on patients with AF. All patients underwent pulmonary vein isolation and additional ablation, which was performed at the discretion of the operator. MAIN OUTCOMES AND MEASURES: The primary effectiveness outcome was freedom from clinically documented atrial arrhythmia for 30 seconds or longer after a 3-month blanking period. The primary safety outcome was the composite of acute (<7 days postprocedure) and chronic (>7 days) major adverse events (MAEs). RESULTS: Of 1568 patients (mean [SD] age, 64.5 [11.5] years; 1015 male [64.7%]) with AF who underwent PFA, female patients, as compared with male patients, were older (mean [SD] age, 68 [10] years vs 62 [12] years; P < .001), had more paroxysmal AF (70.2% [388 of 553] vs 62.4% [633 of 1015]; P = .002) but had fewer comorbidities such as coronary disease (9% [38 of 553] vs 15.9% [129 of 1015]; P < .001), heart failure (10.5% [58 of 553] vs 16.6% [168 of 1015]; P = .001), and sleep apnea (4.7% [18 of 553] vs 11.7% [84 of 1015]; P < .001). Pulmonary vein isolation was performed in 99.8% of female (552 of 553) and 98.9% of male (1004 of 1015; P = .90) patients. Additional ablation was performed in 22.4% of female (124 of 553) and 23.1% of male (235 of 1015; P = .79) patients. The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was similar in male and female patients (79.0%; 95% CI, 76.3%-81.5% vs 76.3%; 95% CI, 72.5%-79.8%; P = .28). There was also no significant difference in acute major AEs between groups (male, 1.5% [16 of 1015] vs female, 2.5% [14 of 553]; P = .19). CONCLUSION AND RELEVANCE: Results of this cohort study suggest that after PFA for AF, there were no significant sex differences in clinical effectiveness or safety events.
- MeSH
- Atrial Fibrillation * drug therapy MeSH
- Cohort Studies MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Retrospective Studies MeSH
- Aged MeSH
- Sex Factors MeSH
- Treatment Outcome MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
BACKGROUND: During electrophysiological mapping of tachycardias, putative target sites are often only truly confirmed to be vital after observing the effect of ablation. This lack of mapping specificity potentiates inadvertent ablation of innocent cardiac tissue not relevant to the arrhythmia. But if myocardial excitability could be transiently suppressed at critical regions, their suitability as targets could be conclusively determined before delivering tissue-destructive ablation lesions. We studied whether reversible pulsed electric fields (PFREV) could transiently suppress electrical conduction, thereby providing a means to dissect tachycardia circuits in vivo. METHODS: PFREV energy was delivered from a 9-mm lattice-tip catheter to the atria of 12 swine and 9 patients, followed by serial electrogram assessments. The effects on electrical conduction were explored in 5 additional animals by applying PFREV to the atrioventricular node: 17 low-dose (PFREV-LOW) and 10 high-dose (PFREV-HIGH) applications. Finally, in 3 patients manifesting spontaneous tachycardias, PFREV was applied at putative critical sites. RESULTS: In animals, the immediate post-PFREV electrogram amplitudes diminished by 74%, followed by 78% recovery by 5 minutes. Similarly, in patients, a 69.9% amplitude reduction was followed by 84% recovery by 3 minutes. Histology revealed only minimal to no focal, superficial fibrosis. PFREV-LOW at the atrioventricular node resulted in transient PR prolongation and transient AV block in 59% and 6%, while PFREV-HIGH caused transient PR prolongation and transient AV block in 30% and 50%, respectively. The 3 tachycardia patients had atypical atrial flutters (n=2) and atrioventricular nodal reentrant tachycardia. PFREV at putative critical sites reproducibly terminated the tachycardias; ablation rendered the tachycardias noninducible and without recurrence during 1-year follow-up. CONCLUSIONS: Reversible electroporation pulses can be applied to myocardial tissue to transiently block electrical conduction. This technique of pulsed field mapping may represent a novel electrophysiological tool to help identify the critical isthmus of tachycardia circuits.
- Keywords
- catheters, electroporation, follow-up studies, swine, transients and migrants,
- MeSH
- Atrioventricular Block * MeSH
- Tachycardia, Atrioventricular Nodal Reentry * MeSH
- Electrophysiologic Techniques, Cardiac MeSH
- Electrocardiography MeSH
- Catheter Ablation * adverse effects methods MeSH
- Humans MeSH
- Atrioventricular Node MeSH
- Swine MeSH
- Animals MeSH
- Check Tag
- Humans MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
AIMS: Single-shot pulmonary vein isolation can improve procedural efficiency. To assess the capability of a novel, expandable lattice-shaped catheter to rapidly isolate thoracic veins using pulsed field ablation (PFA) in healthy swine. METHODS AND RESULTS: The study catheter (SpherePVI; Affera Inc) was used to isolate thoracic veins in two cohorts of swine survived for 1 and 5 weeks. In Experiment 1, an initial dose (PULSE2) was used to isolate the superior vena cava (SVC) and the right superior pulmonary vein (RSPV) in six swine and the SVC only in two swine. In Experiment 2, a final dose (PULSE3) was used for SVC, RSPV, and left superior pulmonary vein (LSPV) in five swine. Baseline and follow-up maps, ostial diameters, and phrenic nerve were assessed. Pulsed field ablation was delivered atop the oesophagus in three swine. All tissues were submitted for pathology. In Experiment 1, all 14/14 veins were isolated acutely with durable isolation demonstrated in 6/6 RSPVs and 6/8 SVC. Both reconnections occurred when only one application/vein was used. Fifty-two and 32 sections from the RSPVs and SVC revealed transmural lesions in 100% with a mean depth of 4.0 ± 2.0 mm. In Experiment 2, 15/15 veins were isolated acutely with 14/15 veins (5/5 SVC, 5/5 RSPV, and 4/5 LSPV) durably isolated. Right superior pulmonary vein (31) and SVC (34) sections had 100% transmural, circumferential ablation with minimal inflammation. Viable vessels and nerves were noted without evidence of venous stenosis, phrenic palsy, or oesophageal injury. CONCLUSION: This novel expandable lattice PFA catheter can achieve durable isolation with transmurality and safety.
- Keywords
- Atrial fibrillation, Catheter ablation, Electroporation • Oesophageal injury, Pulmonary vein, Single shot,
- MeSH
- Atrial Fibrillation * diagnosis surgery pathology MeSH
- Catheter Ablation * adverse effects methods MeSH
- Catheters MeSH
- Swine MeSH
- Feasibility Studies MeSH
- Vena Cava, Superior surgery MeSH
- Pulmonary Veins * surgery pathology MeSH
- Treatment Outcome MeSH
- Animals MeSH
- Check Tag
- Animals MeSH
- Publication type
- Journal Article MeSH
BACKGROUND: The inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed Field Ablation [PFA] System With Irreversible Electroporation [IRE]) evaluated safety and effectiveness of a fully integrated biphasic pulsed field ablation (PFA) system with a variable-loop circular catheter for the treatment of drug-refractory paroxysmal atrial fibrillation. METHODS: Subjects underwent pulmonary vein (PV) isolation with the PFA system, using at least 12 applications per vein; adenosine/isoproterenol was administered to confirm entrance block. Wave I assessed initial safety, including for esophageal lesions, silent cerebral lesions, and PV stenosis. Wave II (pivotal phase) tested (1) primary safety, incidence of early-onset primary adverse events, and (2) primary effectiveness, confirmed PV isolation with freedom from documented atrial arrhythmia at 12 months. The study design specified an interim analysis to determine early success once 30 subjects reached the 12-month follow-up and all subjects reached 3-month follow-up. RESULTS: Across 13 centers in Europe/Canada, 226 subjects were enrolled, met criteria for safety and effectiveness evaluations, and received PFA (Wave I, 40; Wave II, 186). Wave I demonstrated no esophageal thermal lesions or PV stenosis. Among 39 subjects with cerebral magnetic resonance imaging, silent cerebral lesions were detected in 4 of the first 6 subjects, after which workflow enhancements, including a 10-second pause between PFA applications, were implemented; subsequently, only 4 of 33 subjects had silent cerebral lesions. In the Wave II phase, no primary adverse events were reported. Upon declaring early success, 83 subjects reached 12-month follow-up. With 100% entrance block, PV isolation without acute reconnection was achieved in 97.1% of targeted veins. For Wave II, the primary effectiveness end point per Kaplan-Meier at the time of interim analysis was 70.9%; 12-month freedom from symptomatic atrial fibrillation/atrial flutter/atrial tachycardia recurrence and repeat ablation was 78.9% and 92.3%, respectively. Total procedure and transpired PFA times were 70.1±27.7 and 26.7±14.0 minutes, respectively. CONCLUSIONS: The inspIRE trial confirmed the safety and effectiveness of the novel mapping-integrated PFA system. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; unique identifier: NCT04524364.
- Keywords
- atrial fibrillation, catheter ablation, efficacy, electroporation, radiofrequency ablation,
- MeSH
- Atrial Fibrillation * diagnosis surgery etiology MeSH
- Catheter Ablation * adverse effects methods MeSH
- Catheters MeSH
- Humans MeSH
- Recurrence MeSH
- Stenosis, Pulmonary Vein * etiology MeSH
- Constriction, Pathologic etiology surgery MeSH
- Pulmonary Veins * surgery MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Multicenter Study MeSH
- Research Support, Non-U.S. Gov't MeSH
- Geographicals
- Europe MeSH
AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.
- Keywords
- Atrial fibrillation, Catheter ablation, Pulsed field ablation, Survey,
- MeSH
- Stroke * etiology MeSH
- Adult MeSH
- Atrial Fibrillation * diagnosis etiology surgery MeSH
- Catheter Ablation * methods MeSH
- Middle Aged MeSH
- Humans MeSH
- Young Adult MeSH
- Retrospective Studies MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Pulmonary Veins * surgery MeSH
- Treatment Outcome MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Young Adult MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH