Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial Fibrillation

. 2019 Jul 23 ; 74 (3) : 315-326. [epub] 20190511

Jazyk angličtina Země Spojené státy americké Médium print-electronic

Typ dokumentu časopisecké články, pozorovací studie, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/pmid31085321
Odkazy

PubMed 31085321
DOI 10.1016/j.jacc.2019.04.021
PII: S0735-1097(19)34933-2
Knihovny.cz E-zdroje

BACKGROUND: Catheter ablation of atrial fibrillation using thermal energies such as radiofrequency or cryothermy is associated with indiscriminate tissue destruction. During pulsed field ablation (PFA), subsecond electric fields create microscopic pores in cell membranes-a process called electroporation. Among cell types, cardiomyocytes have among the lowest thresholds to these fields, potentially permitting preferential myocardial ablation. OBJECTIVES: The purpose of these 2 trials was to determine whether PFA allows durable pulmonary vein (PV) isolation without damage to collateral structures. METHODS: Two trials were conducted to assess the safety and effectiveness of catheter-based PFA in paroxysmal atrial fibrillation. Ablation was performed using proprietary bipolar PFA waveforms: either monophasic with general anesthesia and paralytics to minimize muscle contraction, or biphasic with sedation because there was minimal muscular stimulation. No esophageal protection strategy was used. Invasive electrophysiological mapping was repeated after 3 months to assess the durability of PV isolation. RESULTS: In 81 patients, all PVs were acutely isolated by monophasic (n = 15) or biphasic (n = 66) PFA with ≤3 min elapsed delivery/patient, skin-to-skin procedure time of 92.2 ± 27.4 min, and fluoroscopy time of 13.1 ± 7.6 min. With successive waveform refinement, durability at 3 months improved from 18% to 100% of patients with all PVs isolated. Beyond 1 procedure-related pericardial tamponade, there were no additional primary adverse events over the 120-day median follow-up, including: stroke, phrenic nerve injury, PV stenosis, and esophageal injury. The 12-month Kaplan-Meier estimate of freedom from arrhythmia was 87.4 ± 5.6%. CONCLUSIONS: In first-in-human trials, PFA preferentially affected myocardial tissue, allowing facile ultra-rapid PV isolation with excellent durability and chronic safety. (IMPULSE: A Safety and Feasibility Study of the IOWA Approach Endocardial Ablation System to Treat Atrial Fibrillation; NCT03700385; and PEFCAT: A Safety and Feasibility Study of the FARAPULSE Endocardial Ablation System to Treat Paroxysmal Atrial Fibrillation; NCT03714178).

Komentář v

PubMed

Citace poskytuje Crossref.org

Nejnovějších 20 citací...

Zobrazit více v
Medvik | PubMed

Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study

. 2024 Jul ; 30 (7) : 2020-2029. [epub] 20240708

Comparing pulsed field electroporation and radiofrequency ablation for the treatment of paroxysmal atrial fibrillation: design and rationale of the BEAT PAROX-AF randomized clinical trial

. 2024 May 02 ; 26 (5) : .

Predictors of Success for Pulmonary Vein Isolation With Pulsed-field Ablation Using a Variable-loop Catheter With 3D Mapping Integration: Complete 12-month Outcomes From inspIRE

. 2024 May ; 17 (5) : e012667. [epub] 20240424

First-in-human clinical series of a novel conformable large-lattice pulsed field ablation catheter for pulmonary vein isolation

. 2024 Mar 30 ; 26 (4) : .

Clinical Outcomes by Sex After Pulsed Field Ablation of Atrial Fibrillation

. 2023 Dec 01 ; 8 (12) : 1142-1151.

Reversible Pulsed Electrical Fields as an In Vivo Tool to Study Cardiac Electrophysiology: The Advent of Pulsed Field Mapping

. 2023 Oct ; 16 (10) : e012018. [epub] 20230920

Preclinical assessment of the feasibility, safety and lesion durability of a novel 'single-shot' pulsed field ablation catheter for pulmonary vein isolation

. 2023 Apr 15 ; 25 (4) : 1369-1378.

Paroxysmal Atrial Fibrillation Ablation Using a Novel Variable-Loop Biphasic Pulsed Field Ablation Catheter Integrated With a 3-Dimensional Mapping System: 1-Year Outcomes of the Multicenter inspIRE Study

. 2023 Mar ; 16 (3) : e011780. [epub] 20230203

Multi-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF)

. 2022 Sep 01 ; 24 (8) : 1256-1266.

How does the level of pulmonary venous isolation compare between pulsed field ablation and thermal energy ablation (radiofrequency, cryo, or laser)?

. 2021 Nov 08 ; 23 (11) : 1757-1766.

Safety, effectiveness, and quality of life following pulmonary vein isolation with a multi-electrode radiofrequency balloon catheter in paroxysmal atrial fibrillation: 1-year outcomes from SHINE

. 2021 Jun 07 ; 23 (6) : 851-860.

AC Pulsed Field Ablation Is Feasible and Safe in Atrial and Ventricular Settings: A Proof-of-Concept Chronic Animal Study

. 2020 ; 8 () : 552357. [epub] 20201203

Pulsed Field Ablation Versus Radiofrequency Ablation: Esophageal Injury in a Novel Porcine Model

. 2020 Mar ; 13 (3) : e008303. [epub] 20200124

Zobrazit více v PubMed

ClinicalTrials.gov
NCT03700385, NCT03714178

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...