Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial Fibrillation
Jazyk angličtina Země Spojené státy americké Médium print-electronic
Typ dokumentu časopisecké články, pozorovací studie, práce podpořená grantem
PubMed
31085321
DOI
10.1016/j.jacc.2019.04.021
PII: S0735-1097(19)34933-2
Knihovny.cz E-zdroje
- Klíčová slova
- atrial fibrillation, catheter ablation, electroporation, esophageal damage, pulmonary vein isolation, pulsed field ablation,
- MeSH
- fibrilace síní chirurgie MeSH
- katetrizační ablace škodlivé účinky metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- senioři MeSH
- studie proveditelnosti MeSH
- venae pulmonales chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
BACKGROUND: Catheter ablation of atrial fibrillation using thermal energies such as radiofrequency or cryothermy is associated with indiscriminate tissue destruction. During pulsed field ablation (PFA), subsecond electric fields create microscopic pores in cell membranes-a process called electroporation. Among cell types, cardiomyocytes have among the lowest thresholds to these fields, potentially permitting preferential myocardial ablation. OBJECTIVES: The purpose of these 2 trials was to determine whether PFA allows durable pulmonary vein (PV) isolation without damage to collateral structures. METHODS: Two trials were conducted to assess the safety and effectiveness of catheter-based PFA in paroxysmal atrial fibrillation. Ablation was performed using proprietary bipolar PFA waveforms: either monophasic with general anesthesia and paralytics to minimize muscle contraction, or biphasic with sedation because there was minimal muscular stimulation. No esophageal protection strategy was used. Invasive electrophysiological mapping was repeated after 3 months to assess the durability of PV isolation. RESULTS: In 81 patients, all PVs were acutely isolated by monophasic (n = 15) or biphasic (n = 66) PFA with ≤3 min elapsed delivery/patient, skin-to-skin procedure time of 92.2 ± 27.4 min, and fluoroscopy time of 13.1 ± 7.6 min. With successive waveform refinement, durability at 3 months improved from 18% to 100% of patients with all PVs isolated. Beyond 1 procedure-related pericardial tamponade, there were no additional primary adverse events over the 120-day median follow-up, including: stroke, phrenic nerve injury, PV stenosis, and esophageal injury. The 12-month Kaplan-Meier estimate of freedom from arrhythmia was 87.4 ± 5.6%. CONCLUSIONS: In first-in-human trials, PFA preferentially affected myocardial tissue, allowing facile ultra-rapid PV isolation with excellent durability and chronic safety. (IMPULSE: A Safety and Feasibility Study of the IOWA Approach Endocardial Ablation System to Treat Atrial Fibrillation; NCT03700385; and PEFCAT: A Safety and Feasibility Study of the FARAPULSE Endocardial Ablation System to Treat Paroxysmal Atrial Fibrillation; NCT03714178).
Homolka Hospital Prague Czech Republic
Homolka Hospital Prague Czech Republic; Icahn School of Medicine at Mount Sinai New York New York
Icahn School of Medicine at Mount Sinai New York New York https twitter com jskoruth
Icahn School of Medicine at Mount Sinai New York New York https twitter com SriniDukkipati
IHU LIRYC ANR 10 IAHU 04 University of Bordeaux CHU Bordeaux Bordeaux France
Citace poskytuje Crossref.org
Clinical Outcomes by Sex After Pulsed Field Ablation of Atrial Fibrillation
Pulsed Field Ablation Versus Radiofrequency Ablation: Esophageal Injury in a Novel Porcine Model
ClinicalTrials.gov
NCT03700385, NCT03714178