Nejvíce citovaný článek - PubMed ID 34904233
Extracorporeal membrane oxygenation seems to induce impairment of primary hemostasis pathology as measured by a Multiplate analyzer: An observational retrospective study
Background: Extracorporeal membrane oxygenation (ECMO) is frequently used during lung transplantation. Unfractionated heparin (UFH) is mainly used as part of ECMO support for anticoagulation. One of the most common perioperative complications is bleeding, which high-dose UFH can aggravate. Methods: We retrospectively analyzed (n = 141) patients who underwent lung transplantation between 2020 and 2022. All subjects (n = 109) underwent central cannulated VA ECMO with successful intraoperative ECMO weaning. Patients on ECMO bridge, postoperative ECMO, heart-lung transplants and transplants without ECMO were excluded. The dose of UFH for the entire surgical procedure, blood loss and consumption of blood derivatives intraoperatively and 48 h after ICU admission were recorded. Surgical revision for postoperative bleeding were analyzed. Thrombotic complications, mortality and long-term survival were evaluated. Results: Lower doses of UFH administered for intraoperative ECMO anticoagulation contribute to a reduction in intraoperative blood derivates consumption and blood loss with no thrombotic complications related to the patient or the ECMO circuit. Lower doses of UFH may lead to a decreased incidence of surgical revision for hemothorax. Conclusion: Lower doses of UFH as part of intraoperative ECMO anticoagulation might reduce the incidence of complications and lead to better postoperative outcomes.
- Klíčová slova
- ECMO, UFH, anesthesiology, anticoagulation, lung transplantation,
- MeSH
- antikoagulancia terapeutické užití MeSH
- heparin terapeutické užití MeSH
- lidé MeSH
- mimotělní membránová oxygenace * škodlivé účinky MeSH
- pooperační krvácení MeSH
- retrospektivní studie MeSH
- transplantace plic * metody MeSH
- trombóza * etiologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- Názvy látek
- antikoagulancia MeSH
- heparin MeSH
BACKGROUND: Unfractionated heparin is used worldwide as a standard anticoagulation therapy for extracorporeal membrane oxygenation (ECMO) machines. However, its use brings about significant bleeding and thrombotic complications for critically ill patients. This case report shows that low molecular weight heparin together with ECMO-produced primary haemostasis pathology can be used as an alternative way of ECMO anticoagulation. CASE PRESENTATION: This paper presents the case of a patient with respiratory failure who subsequently suffered from cardiac failure and spent 94 days on combined V-V and V-A ECMO devices (two ECMO devices running simultaneously on one patient) with intravenous enoxaparin used instead of unfractionated heparin anticoagulation. No life-threatening bleeding/thrombotic events happened during this period, nor did any technical problems with ECMO occur. CONCLUSIONS: In this case report, continuous intravenous low molecular weight heparin anticoagulation was used as a safe alternative to ECMO anticoagulation.
- Klíčová slova
- ECMO, Enoxaparin, Extracorporeal membrane oxygenation, LMWH, PFA 200, Primary haemostasis,
- MeSH
- antikoagulancia škodlivé účinky MeSH
- enoxaparin MeSH
- heparin nízkomolekulární MeSH
- heparin škodlivé účinky MeSH
- krvácení etiologie MeSH
- lidé MeSH
- mimotělní membránová oxygenace * škodlivé účinky MeSH
- trombóza * etiologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
- Názvy látek
- antikoagulancia MeSH
- enoxaparin MeSH
- heparin nízkomolekulární MeSH
- heparin MeSH