Temperature transducers are commonly used to monitor process parameters that are controlled by various types of industrial controllers. The purpose of this study is to design and model a simple microcontroller-based acoustic temperature transducer based on the variations of resonance conditions in a cylindrical resonance tube. The transducer's operation is based on the generation of an acoustic standing wave in the free resonance mode of generation within a cylindrical resonance tube which is converted into a train of pulses using Schmitt trigger circuit. The frequency of the generated standing wave (i.e., the train of pulses) is measured by the Arduino Uno microcontroller, where a digital pin is used to acquire pulses that are counted using a build-in software function in an Arduino IDE environment. Experimental results are performed for three sizes of diameters to investigate the effect of the diameter of resonance tube on the obtained results. The maximum nonlinearity error according to Full-Scale Deflection (FSD) is about 2.3 percent, and the relative error of the transducer is evaluated using experimental findings and the regression model. The circuit simplicity and design of the suggested transducer, as well as the linearity of its measurements, are notable.
- Keywords
- Arduino Uno, acoustic resonance, standing wave, temperature measurement,
- MeSH
- Acoustics * MeSH
- Transducers MeSH
- Temperature MeSH
- Vibration MeSH
- Sound * MeSH
- Publication type
- Journal Article MeSH
Environmental screening is essential due to the increased occurrence of harmful substances in the environment. Open Meter Duo (OMD) is an open-source field photo/fluorimeter that uses an RGB diode that imitates a color according to the selected wavelength and uses a UV LED from the security kit diode as an excitation light source. The prepared PCB shield with a 3D-printed aperture was connected to Arduino UNO R4 WiFi. This system was used for the fluorescent detection of cholinesterase activity with the indoxyl acetate method. Carbofuran-a toxic pesticide-and donepezil-a drug used to treat Alzheimer's disease-were tested as model inhibitors of cholinesterase activity. The limit of detection of indoxyl acetate was 11.6 μmol/L, and the IC50 values of the inhibitors were evaluated. This system is optimized for wireless use in field analysis with added cloud support and power source. The time of analysis was 5 min for the fluorimetric assay and 20 min for the optional photometric assay. The time of field operation was approximately 4 h of continuous measurement. This system is ready to be used as a cheap and easy control platform for portable use in drug control and point-of-care testing.
- Keywords
- 3D printing, Arduino, cholinesterase, fluorimetry, low cost, portable, remote sensing,
- MeSH
- Alzheimer Disease * MeSH
- Cholinesterase Inhibitors therapeutic use MeSH
- Cholinesterases therapeutic use MeSH
- Donepezil therapeutic use MeSH
- Fluorometry MeSH
- Humans MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Names of Substances
- Cholinesterase Inhibitors MeSH
- Cholinesterases MeSH
- Donepezil MeSH