Something wrong with this record ?
Prostacyclin versus citrate in continuous haemodiafiltration: an observational study in patients with high risk of bleeding
Balik M, Waldauf P, Plásil P, Pachl J.
Language English Country Switzerland
Document type Comparative Study
NLK
Karger Journals
from 1983 to 2009
- MeSH
- Anticoagulants administration & dosage economics MeSH
- Epoprostenol administration & dosage economics MeSH
- Glucose analogs & derivatives administration & dosage MeSH
- Hemodiafiltration methods standards MeSH
- Heparin administration & dosage MeSH
- Hemorrhage prevention & control MeSH
- Citric Acid administration & dosage MeSH
- Middle Aged MeSH
- Humans MeSH
- Risk MeSH
- Aged MeSH
- Blood Platelets drug effects MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Comparative Study MeSH
BACKGROUND: The efficacy and safety of prostacyclin (PGI2) and citrate (ACD) anticoagulation were observed and compared during continuous haemodiafiltration. METHODS: Mechanically ventilated patients received either the PGI2 analogue epoprostenol (group A, n = 17) in escalating doses of 4.5-10.0 ng.kg(-1).min(-1) in combination with heparin (6 IU.kg(-1).h(-1)) or 2.2% ACD (group B, n = 15). Blood flow was set to match the circuit-filling volume per unit time equal to the intravascular half-life of PGI2. RESULTS: Median filter lifetimes were 26 h (interquartile range 16-37) in group A (39 filters) and 36.5 h (interquartile range 23-50) in group B (56 filters; p < 0.01). In group A, 4 patients (23.5%, p < 0.05) had the dose reduced due to hypotension. The final mean dose of PGI2 was 8.7 +/- 2.4 ng.kg(-1).min(-1). Four patients in group A (23.5%, p < 0.05) were switched to ACD due to a decrease in platelet count. No bleeding episodes, decrease in platelet count or adverse haemodynamic effects were encountered in group B. The cost of epoprostenol plus low dose heparin (EUR 204.73 +/- 53.04) was significantly higher than the cost of ACD-based anticoagulation (EUR 93.92 +/- 45.2, p < 0.05). CONCLUSION: ACD offers longer filter survival, has no impact on platelet count and is less expensive. Increasing the dose of PGI2 up to the average of 8.7 ng.kg(-1).min(-1) did not increase the haemodynamic side effects. (c) 2005 S. Karger AG, Basel
- 000
- 03709naa 2200493 a 4500
- 001
- bmc07507143
- 003
- CZ-PrNML
- 005
- 20111210122825.0
- 008
- 080730s2005 sz e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Balík, Martin $7 xx0075661
- 245 10
- $a Prostacyclin versus citrate in continuous haemodiafiltration: an observational study in patients with high risk of bleeding / $c Balik M, Waldauf P, Plásil P, Pachl J.
- 314 __
- $a Department Anaesthesia and Intensive Care, University Hospital Kralovske Vinohrady, Prague, Czech Republic. balik@fnkv.cz
- 520 9_
- $a BACKGROUND: The efficacy and safety of prostacyclin (PGI2) and citrate (ACD) anticoagulation were observed and compared during continuous haemodiafiltration. METHODS: Mechanically ventilated patients received either the PGI2 analogue epoprostenol (group A, n = 17) in escalating doses of 4.5-10.0 ng.kg(-1).min(-1) in combination with heparin (6 IU.kg(-1).h(-1)) or 2.2% ACD (group B, n = 15). Blood flow was set to match the circuit-filling volume per unit time equal to the intravascular half-life of PGI2. RESULTS: Median filter lifetimes were 26 h (interquartile range 16-37) in group A (39 filters) and 36.5 h (interquartile range 23-50) in group B (56 filters; p < 0.01). In group A, 4 patients (23.5%, p < 0.05) had the dose reduced due to hypotension. The final mean dose of PGI2 was 8.7 +/- 2.4 ng.kg(-1).min(-1). Four patients in group A (23.5%, p < 0.05) were switched to ACD due to a decrease in platelet count. No bleeding episodes, decrease in platelet count or adverse haemodynamic effects were encountered in group B. The cost of epoprostenol plus low dose heparin (EUR 204.73 +/- 53.04) was significantly higher than the cost of ACD-based anticoagulation (EUR 93.92 +/- 45.2, p < 0.05). CONCLUSION: ACD offers longer filter survival, has no impact on platelet count and is less expensive. Increasing the dose of PGI2 up to the average of 8.7 ng.kg(-1).min(-1) did not increase the haemodynamic side effects. (c) 2005 S. Karger AG, Basel
- 650 _2
- $a antikoagulancia $x aplikace a dávkování $x ekonomika $7 D000925
- 650 _2
- $a kyselina citronová $x aplikace a dávkování $7 D019343
- 650 _2
- $a epoprostenol $x aplikace a dávkování $x ekonomika $7 D011464
- 650 _2
- $a glukosa $x analogy a deriváty $x aplikace a dávkování $7 D005947
- 650 _2
- $a hemodiafiltrace $x metody $x normy $7 D017583
- 650 _2
- $a krvácení $x prevence a kontrola $7 D006470
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a trombocyty $x účinky léků $7 D001792
- 650 _2
- $a heparin $x aplikace a dávkování $7 D006493
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a riziko $7 D012306
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 655 _2
- $a srovnávací studie $7 D003160
- 700 1_
- $a Waldauf, Petr $7 xx0085547
- 700 1_
- $a Plášil, Petr $7 xx0085549
- 700 1_
- $a Pachl, Jan, $d 1949- $7 nlk19990073644
- 773 0_
- $w MED00000812 $t Blood purification $g Roč. 23, č. 4 (2005), s. 325-329 $x 0253-5068
- 910 __
- $y 9 $a ABA008 $b x
- 990 __
- $a 20080721085927 $b ABA008
- 991 __
- $a 20081027150100 $b ABA008
- 999 __
- $a ok $b bmc $g 622751 $s 475184
- BAS __
- $a 3
- BMC __
- $a 2005 $b 23 $c 4 $d 325-329 $i 0253-5068 $m Blood purification $x MED00000812
- LZP __
- $a 2008-Doreen