• Je něco špatně v tomto záznamu ?

Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of phenylephrine in human plasma and its application to a pharmacokinetic study

P Ptacek, J Klima, J Macek

. 2007 ; 858 (1-2 Oct) : 263-268.

Jazyk angličtina Země Nizozemsko

Typ dokumentu validační studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc10012671

A sensitive and reliable method was developed to quantitate phenylephrine in human plasma using liquid chromatography-electrospray tandem mass spectrometry. The assay was based on solid-phase extraction with C18 cartridges and hydrophilic interaction chromatography performed on a pentafluorophenylpropylsilica column (50 mm x 4 mm, 3 microm particles), the mobile phase consisted of methanol-10 mM ammonium acetate (90:10, v/v). Quantification was through positive-ion mode and selected reaction monitoring at m/z 168.1-->135.0 for phenylephrine and m/z 182.1-->135.0 for internal standard etilefrin, respectively. The lower limit of quantitation was 51 pg/ml using 0.25 ml of plasma and linearity was observed from 51 to 5500 pg/ml. Within-day and between-day precision expressed by relative standard deviation was less than 12% and inaccuracy did not exceed 8% at all levels. The assay was applied to the analysis of samples from a pharmacokinetic study.

000      
02754naa 2200385 a 4500
001      
bmc10012671
003      
CZ-PrNML
005      
20111210163256.0
008      
100526s2007 ne e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Ptáček, Pavel $7 xx0064070
245    10
$a Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of phenylephrine in human plasma and its application to a pharmacokinetic study / $c P Ptacek, J Klima, J Macek
314    __
$a Pharmakl s.r.o., Seydlerova 2451, CZ-15800 Prague 13, Czech Republic. ptacek@pharmakl.cz
520    9_
$a A sensitive and reliable method was developed to quantitate phenylephrine in human plasma using liquid chromatography-electrospray tandem mass spectrometry. The assay was based on solid-phase extraction with C18 cartridges and hydrophilic interaction chromatography performed on a pentafluorophenylpropylsilica column (50 mm x 4 mm, 3 microm particles), the mobile phase consisted of methanol-10 mM ammonium acetate (90:10, v/v). Quantification was through positive-ion mode and selected reaction monitoring at m/z 168.1-->135.0 for phenylephrine and m/z 182.1-->135.0 for internal standard etilefrin, respectively. The lower limit of quantitation was 51 pg/ml using 0.25 ml of plasma and linearity was observed from 51 to 5500 pg/ml. Within-day and between-day precision expressed by relative standard deviation was less than 12% and inaccuracy did not exceed 8% at all levels. The assay was applied to the analysis of samples from a pharmacokinetic study.
650    _2
$a agonisté adrenergních alfa-receptorů $x farmakokinetika $x krev $7 D000316
650    _2
$a chromatografie kapalinová $x metody $7 D002853
650    _2
$a lidé $7 D006801
650    _2
$a molekulární struktura $7 D015394
650    _2
$a fenylefrin $x farmakokinetika $x krev $x normy $7 D010656
650    _2
$a referenční standardy $7 D012015
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a rozpouštědla $x chemie $7 D012997
650    _2
$a hmotnostní spektrometrie s elektrosprejovou ionizací $x metody $7 D021241
650    _2
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
655    _2
$a validační studie $7 D023361
700    1_
$a Klíma, Jiří $7 xx0106475
700    1_
$a Macek, Jan $7 xx0061837
773    0_
$t Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences $w MED00006642 $g Roč. 858, č. 1-2 Oct (2007), s. 263-268 $x 1570-0232
910    __
$a ABA008 $b x $y 8
990    __
$a 20100531092626 $b ABA008
991    __
$a 20100916082318 $b ABA008
999    __
$a ok $b bmc $g 726526 $s 589682
BAS    __
$a 3
BMC    __
$a 2007 $b 858 $c 1-2 Oct $d 263-268 $i 1570-0232 $m Journal of chromatography. B, Analytical technologies in the biomedical and life sciences $n J Chromatogr B Analyt Technol Biomed Life Sci $x MED00006642
LZP    __
$a 2010-B2/vtme