Two-dimensional blind Bayesian deconvolution of medical ultrasound images
R Jirik, T Taxt
Language English Country United States
Document type Research Support, Non-U.S. Gov't
PubMed
18986863
DOI
10.1109/tuffc.914
Knihovny.cz E-resources
- MeSH
- Algorithms MeSH
- Bayes Theorem MeSH
- Image Interpretation, Computer-Assisted methods MeSH
- Reproducibility of Results MeSH
- Pattern Recognition, Automated methods MeSH
- Sensitivity and Specificity MeSH
- Ultrasonography methods MeSH
- Artificial Intelligence MeSH
- Image Enhancement methods MeSH
- Publication type
- Research Support, Non-U.S. Gov't MeSH
A new approach to 2-D blind deconvolution of ultrasonic images in a Bayesian framework is presented. The radio-frequency image data are modeled as a convolution of the point-spread function and the tissue function, with additive white noise. The deconvolution algorithm is derived from statistical assumptions about the tissue function, the point-spread function, and the noise. It is solved as an iterative optimization problem. In each iteration, additional constraints are applied as a projection operator to further stabilize the process. The proposed method is an extension of the homomorphic deconvolution, which is used here only to compute the initial estimate of the point-spread function. Homomorphic deconvolution is based on the assumption that the point-spread function and the tissue function lie in different bands of the cepstrum domain, which is not completely true. This limiting constraint is relaxed in the subsequent iterative deconvolution. The deconvolution is applied globally to the complete radiofrequency image data. Thus, only the global part of the point-spread function is considered. This approach, together with the need for only a few iterations, makes the deconvolution potentially useful for real-time applications. Tests on phantom and clinical images have shown that the deconvolution gives stable results of clearly higher spatial resolution and better defined tissue structures than in the input images and than the results of the homomorphic deconvolution alone.
References provided by Crossref.org
- 000
- 02889naa 2200325 a 4500
- 001
- bmc11006315
- 003
- CZ-PrNML
- 005
- 20221104161701.0
- 008
- 110401s2008 xxu e eng||
- 009
- AR
- 024 7_
- $a 10.1109/TUFFC.914 $2 doi
- 035 __
- $a (PubMed)18986863
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Jiřík, Radovan. $7 xx0241067
- 245 10
- $a Two-dimensional blind Bayesian deconvolution of medical ultrasound images / $c R Jirik, T Taxt
- 314 __
- $a Brno University of Technology, Department of Biomedical Engineering, Brno, Czech Republic. jirik@feec.vutbr.cz
- 520 9_
- $a A new approach to 2-D blind deconvolution of ultrasonic images in a Bayesian framework is presented. The radio-frequency image data are modeled as a convolution of the point-spread function and the tissue function, with additive white noise. The deconvolution algorithm is derived from statistical assumptions about the tissue function, the point-spread function, and the noise. It is solved as an iterative optimization problem. In each iteration, additional constraints are applied as a projection operator to further stabilize the process. The proposed method is an extension of the homomorphic deconvolution, which is used here only to compute the initial estimate of the point-spread function. Homomorphic deconvolution is based on the assumption that the point-spread function and the tissue function lie in different bands of the cepstrum domain, which is not completely true. This limiting constraint is relaxed in the subsequent iterative deconvolution. The deconvolution is applied globally to the complete radiofrequency image data. Thus, only the global part of the point-spread function is considered. This approach, together with the need for only a few iterations, makes the deconvolution potentially useful for real-time applications. Tests on phantom and clinical images have shown that the deconvolution gives stable results of clearly higher spatial resolution and better defined tissue structures than in the input images and than the results of the homomorphic deconvolution alone.
- 590 __
- $a bohemika - dle Pubmed
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a umělá inteligence $7 D001185
- 650 _2
- $a Bayesova věta $7 D001499
- 650 _2
- $a vylepšení obrazu $x metody $7 D007089
- 650 _2
- $a interpretace obrazu počítačem $x metody $7 D007090
- 650 _2
- $a rozpoznávání automatizované $x metody $7 D010363
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a ultrasonografie $x metody $7 D014463
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Taxt, Torfinn
- 773 0_
- $t IEEE transactions on ultrasonics, ferroelectrics, and frequency control $w MED00209835 $g Roč. 55, č. 10 (2008), s. 2140-2153 $x 0885-3010
- 910 __
- $a ABA008 $b x $y 2 $z 0
- 990 __
- $a 20110414103812 $b ABA008
- 991 __
- $a 20221104161653 $b ABA008
- 999 __
- $a ok $b bmc $g 833917 $s 698411
- BAS __
- $a 3
- BMC __
- $a 2008 $b 55 $c 10 $d 2140-2153 $m IEEE transactions on ultrasonics, ferroelectrics, and frequency control $i 0885-3010 $n IEEE Trans Ultrason Ferroelectr Freq Control $x MED00209835
- LZP __
- $a 2011-1B09/jjme