• Je něco špatně v tomto záznamu ?

Determination of chloramphenicol in urine, feed water, milk and honey samples using molecular imprinted polymer clean-up

M Rejtharova, L Rejthar

Jazyk angličtina Země Nizozemsko

Typ dokumentu hodnotící studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc12008652

A method for determination of low concentrations of chloramphenicol in urine, feed water, milk and honey was developed. A comparison was carried out between a routinely used analytical method based on solid phase extraction (SPE-C18) for cleaning the extract and the new procedure for the sample preparation using columns based on the molecular imprinted polymers (MIP) principle. The extracts obtained from the MIP clean-up procedure were clean enough for chromatografic analyses. Confirmatory analyses were conducted using GC/MS-NCI after derivatisation (silylation). The described method was fully validated according to CD 2002/657/EC. This method is considerably robust and allows very dirty samples to be processed. The described MIP procedure is very simple and low-time-consuming, and provides high throughput of the samples examined. This could be used for routine screening and confirmatory analyses as well.

000      
02350naa a2200373 a 4500
001      
bmc12008652
003      
CZ-PrNML
005      
20141106105927.0
008      
120316s2009 ne eng||
009      
AR
040    __
$a ABA008 $b cze $d ABA008
041    0_
$a eng
044    __
$a ne
100    1_
$a Rejtharová, Martina $u Institute for State Control of Veterinary Biologicals and Medicaments, CZ 621 00 Brno, Czech Republic $7 _AN080444
245    10
$a Determination of chloramphenicol in urine, feed water, milk and honey samples using molecular imprinted polymer clean-up / $c M Rejtharova, L Rejthar
520    9_
$a A method for determination of low concentrations of chloramphenicol in urine, feed water, milk and honey was developed. A comparison was carried out between a routinely used analytical method based on solid phase extraction (SPE-C18) for cleaning the extract and the new procedure for the sample preparation using columns based on the molecular imprinted polymers (MIP) principle. The extracts obtained from the MIP clean-up procedure were clean enough for chromatografic analyses. Confirmatory analyses were conducted using GC/MS-NCI after derivatisation (silylation). The described method was fully validated according to CD 2002/657/EC. This method is considerably robust and allows very dirty samples to be processed. The described MIP procedure is very simple and low-time-consuming, and provides high throughput of the samples examined. This could be used for routine screening and confirmatory analyses as well.
590    __
$a bohemika - dle Pubmed
650    02
$a krmivo pro zvířata $x analýza $7 D000821
650    02
$a zvířata $7 D000818
650    02
$a antibakteriální látky $x moč $7 D000900
650    02
$a skot $7 D002417
650    02
$a chloramfenikol $x moč $7 D002701
650    02
$a chromatografie $x metody $x přístrojové vybavení $7 D002845
650    02
$a med $x analýza $7 D006722
650    02
$a mléko $x chemie $7 D008892
650    02
$a molekulový imprinting $7 D054802
650    02
$a polymery $x chemie $7 D011108
650    02
$a prasata $7 D013552
650    02
$a voda $x analýza $7 D014867
655    _2
$a hodnotící studie $7 D023362
700    1#
$a Rejthar, Libor $7 _AN080445 $u Institute for State Control of Veterinary Biologicals and Medicaments, CZ 621 00 Brno, Czech Republic
773    0_
$t Journal of Chromatography. A $p J Chromatogr $g Roč. 1216, č. 46 (2009), s. 8246-8253 $w MED00004962 $x 0020-8868
773    0_
$p J Chromatogr $g 1216(46):8246-53, 2009 Nov 13
910    __
$a ABA008 $b x $y 4 $z 0
990    __
$a 20120319124607 $b ABA008
991    __
$a 20141106105936 $b ABA008
999    __
$a ok $b bmc $g 901996 $s 765547
BAS    __
$a 3
BMC    __
$a 2009 $b 1216 $c 46 $d 8246-8253 $m Journal of chromatography. A, Including electrophoresis and other separation methods $x MED00004962
LZP    __
$a 2012-1Q10/

Najít záznam