Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Současné poznatky o vlivu technologie výroby a sterilizace na strukturu, vlastnosti a životnost UHMWPE v kloubních náhradách
[Current knowledge on the effect of technology and sterilization on the structure, properties and longevity of uhmwpe in total joint replacement]

D. Pokorný, M. Šlouf, P. Fulín

. 2012 ; 79 (3) : 213-221.

Language Czech Country Czech Republic

Document type Review

Grant support
NT12229 MZ0 CEP Register

Ultrahigh molecular weight polyethylene (UHMWPE) is the most frequently used bearing surface in currently used total joint replacements (TJR). According to the literature available, UHMWPE is the best polymer material, in terms of biocompatibility, mechanical properties and wear resistance, for this application. In spite of this fact, UHMWPE wear (i.e., release of microscopic particles from the polymer surface) remains one of the main reasons of TJR failures. Consequently, the wear of UHMWPE is a subject of intensive study by both materials scientists and orthopaedic surgeons. The structure and properties of UHMWPE strongly depend on the way of processing and post-processing modifications. The processing includes polymer resin preparation (microparticles about 100 urn in size) and resin consolidation (forming bulk material). Post-processing modifications aim at increasing wear resistance and oxidation stability which are regarded as major factors involved in TJR failure. In order to maintain high purity materials for medical application, it is not allowed to use additional chemicals during the modification processes. The only exception is the use of vitamin E, a natural stabilizer and antioxidant. Considering all the above mentioned facts, the modifications can be based on (I) ionizing radiation such as gamma rays or accelerated electrons, (II) thermal modification, (III) additional stabilization with vitamin E, and (IV) sterilization. According to the modifications, we usually differentiate three generations of UHMWPE. The 1st generation UHMWPE is not modified except for obligatory sterilization. The sterilization procedures based on chemical procedures (formaldehyde vapours, hot water) have lately been forbidden, abandoned and replaced by gamma-irradiation with doses of 25-45 kGy In the course of time, sterilization by means of gamma-irradiation showed to be unsuitable due to oxidative degradation of UHMWPE, which resulted in lower wear resistance, worse material properties and a decrease in longevity of joint replacements. The 2nd generation UHMWPE or highly cross-linked UHMWPE is material treated with ionizing radiation (gamma-rays or accelerated electrons) at higher doses (usually 50-100 kGy). The irradiation is followed by thermal treatment in order to eliminate residual radicals and limit oxidative degradation that occurs in the 1st generation UHMWPE types. Finally, the material is sterilized usually by modern procedures using ethylene oxide or gas plasma neither of which causes oxidative degradation (as opposed to gamma-irradiation sterilization). The 3rd generation UHMWPE is basically the same as that of the 2nd generation. The main difference consists in slightly better mechanical properties (strength, fatigue) and further stabilization to oxidative degradation. This is achieved by special procedures, some of which are either controversial (sequential irradiation) or well-accepted by a great majority of the orthopaedic community (vitamin E stabilization). Only the future will show whether the difference between the 2nd and 3rd generations of UHMWPE will play any role in increasing TJR longevity and therefore the quality of its performance. The final objective of all of UHMWPE modifications is, as already mentioned, to increase wear resistance, oxidative resistance and mechanical performance of the polymer. These changes, especially an increase in wear resistance, have been confirmed to prolong the longevity of total joint replacements based on UHMWPE.

Current knowledge on the effect of technology and sterilization on the structure, properties and longevity of uhmwpe in total joint replacement

References provided by Crossref.org

Obsahuje 1tabulku

Bibliography, etc.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc12021447
003      
CZ-PrNML
005      
20170427100607.0
007      
ta
008      
120801s2012 xr daf f 000 0cze||
009      
AR
024    7_
$a 10.55095/achot2012/031 $2 doi
035    __
$a (PubMed)22840952
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Pokorný, David, $d 1968- $7 jn20001103568 $u I. Ortopedická klinika 1. LF UK Praha, FN Motol, Praha
245    10
$a Současné poznatky o vlivu technologie výroby a sterilizace na strukturu, vlastnosti a životnost UHMWPE v kloubních náhradách / $c D. Pokorný, M. Šlouf, P. Fulín
246    31
$a Current knowledge on the effect of technology and sterilization on the structure, properties and longevity of uhmwpe in total joint replacement
500    __
$a Obsahuje 1tabulku
504    __
$a Literatura $b 33
520    9_
$a Ultrahigh molecular weight polyethylene (UHMWPE) is the most frequently used bearing surface in currently used total joint replacements (TJR). According to the literature available, UHMWPE is the best polymer material, in terms of biocompatibility, mechanical properties and wear resistance, for this application. In spite of this fact, UHMWPE wear (i.e., release of microscopic particles from the polymer surface) remains one of the main reasons of TJR failures. Consequently, the wear of UHMWPE is a subject of intensive study by both materials scientists and orthopaedic surgeons. The structure and properties of UHMWPE strongly depend on the way of processing and post-processing modifications. The processing includes polymer resin preparation (microparticles about 100 urn in size) and resin consolidation (forming bulk material). Post-processing modifications aim at increasing wear resistance and oxidation stability which are regarded as major factors involved in TJR failure. In order to maintain high purity materials for medical application, it is not allowed to use additional chemicals during the modification processes. The only exception is the use of vitamin E, a natural stabilizer and antioxidant. Considering all the above mentioned facts, the modifications can be based on (I) ionizing radiation such as gamma rays or accelerated electrons, (II) thermal modification, (III) additional stabilization with vitamin E, and (IV) sterilization. According to the modifications, we usually differentiate three generations of UHMWPE. The 1st generation UHMWPE is not modified except for obligatory sterilization. The sterilization procedures based on chemical procedures (formaldehyde vapours, hot water) have lately been forbidden, abandoned and replaced by gamma-irradiation with doses of 25-45 kGy In the course of time, sterilization by means of gamma-irradiation showed to be unsuitable due to oxidative degradation of UHMWPE, which resulted in lower wear resistance, worse material properties and a decrease in longevity of joint replacements. The 2nd generation UHMWPE or highly cross-linked UHMWPE is material treated with ionizing radiation (gamma-rays or accelerated electrons) at higher doses (usually 50-100 kGy). The irradiation is followed by thermal treatment in order to eliminate residual radicals and limit oxidative degradation that occurs in the 1st generation UHMWPE types. Finally, the material is sterilized usually by modern procedures using ethylene oxide or gas plasma neither of which causes oxidative degradation (as opposed to gamma-irradiation sterilization). The 3rd generation UHMWPE is basically the same as that of the 2nd generation. The main difference consists in slightly better mechanical properties (strength, fatigue) and further stabilization to oxidative degradation. This is achieved by special procedures, some of which are either controversial (sequential irradiation) or well-accepted by a great majority of the orthopaedic community (vitamin E stabilization). Only the future will show whether the difference between the 2nd and 3rd generations of UHMWPE will play any role in increasing TJR longevity and therefore the quality of its performance. The final objective of all of UHMWPE modifications is, as already mentioned, to increase wear resistance, oxidative resistance and mechanical performance of the polymer. These changes, especially an increase in wear resistance, have been confirmed to prolong the longevity of total joint replacements based on UHMWPE.
650    02
$a artroplastiky kloubů $7 D019643
650    02
$a biokompatibilní materiály $7 D001672
650    02
$a biomechanika $7 D001696
650    02
$a lidé $7 D006801
650    02
$a protézy kloubů $7 D007595
650    02
$a polyethyleny $x chemie $x účinky záření $7 D011095
650    02
$a sterilizace $7 D013242
655    _2
$a přehledy $7 D016454
700    1_
$a Šlouf, Miroslav, $d 1973- $7 xx0107048 $u Ústav makromolekulami chemie AV ČR, v.v.i., Praha
700    1_
$a Fulín, Petr. $7 xx0231618 $u I. Ortopedická klinika 1. LF UK Praha, FN Motol, Praha
773    0_
$t Acta chirurgiae orthopaedicae et traumatologiae čechoslovaca $x 0001-5415 $g Roč. 79, č. 3 (2012), s. 213-221 $w MED00011021
910    __
$a ABA008 $b A 8 $c 507 $y 3 $z 0
990    __
$a 20120801115006 $b ABA008
991    __
$a 20170427100927 $b ABA008
999    __
$a ok $b bmc $g 943318 $s 778732
BAS    __
$a 3
BMC    __
$a 2012 $b 79 $c 3 $d 213-221 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
GRA    __
$a NT12229 $p MZ0
LZP    __
$a 2012-33/dkme

Find record

Citation metrics

Logged in users only

Archiving options

Loading data ...