Trace determination of perchlorate using electromembrane extraction and capillary electrophoresis with capacitively coupled contactless conductivity detection
IK. Kiplagat, TK. Doan, P. Kubáň, P. Boček
Language English Country Germany
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Chemical Fractionation instrumentation methods MeSH
- Rain chemistry MeSH
- Electric Conductivity MeSH
- Electrophoresis, Capillary methods MeSH
- Electrolytes chemistry MeSH
- Heptanol chemistry MeSH
- Histidine chemistry MeSH
- Hydrogen-Ion Concentration MeSH
- Acetic Acid chemistry MeSH
- Membranes, Artificial MeSH
- Perchlorates analysis isolation & purification MeSH
- Reproducibility of Results MeSH
- Sensitivity and Specificity MeSH
- Water chemistry MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
Electromembrane extraction (EME) and CE with capacitively coupled contactless conductivity detection (CE-C(4) D) was applied to rapid and sensitive determination of perchlorate in drinking water and environmental samples. Porous polypropylene hollow fiber impregnated with 1-heptanol acted as a supported liquid membrane (SLM) and perchlorate was transported and preconcentrated in the fiber lumen on application of electric field. High selectivity of perchlorate determination and its baseline separation from major inorganic anions was achieved in CE-C(4) D using background electrolyte solution consisting of 7.5 mM L-histidine and 40 mM acetic acid at pH 4.1. The analytical method showed excellent parameters in terms of reproducibility; RSD values for migration times and peak areas at a spiked concentration of 15 μg/L of perchlorate (US EPA recommended limit for drinking water) were below 0.2 and 8.7%, respectively, in all examined water samples. Linear calibration curves were obtained for perchlorate in the concentration range 1-100 μg/L (r(2) ≥0.999) with limits of detection at 1 μg/L for tap water and at 0.25-0.35 μg/L for environmental and bottled potable water samples. Recoveries at 15 μg/L of perchlorate were between 95.9 and 106.7% with minimum and maximum recovery values for snow and bottled potable water samples, respectively.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12022225
- 003
- CZ-PrNML
- 005
- 20160321091418.0
- 007
- ta
- 008
- 120806s2011 gw f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1002/elps.201100279 $2 doi
- 035 __
- $a (PubMed)22002888
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Kiplagat, Isaac K. $u Department of Chemistry and Biochemistry, Mendel University Brno, Czech Republic
- 245 10
- $a Trace determination of perchlorate using electromembrane extraction and capillary electrophoresis with capacitively coupled contactless conductivity detection / $c IK. Kiplagat, TK. Doan, P. Kubáň, P. Boček
- 520 9_
- $a Electromembrane extraction (EME) and CE with capacitively coupled contactless conductivity detection (CE-C(4) D) was applied to rapid and sensitive determination of perchlorate in drinking water and environmental samples. Porous polypropylene hollow fiber impregnated with 1-heptanol acted as a supported liquid membrane (SLM) and perchlorate was transported and preconcentrated in the fiber lumen on application of electric field. High selectivity of perchlorate determination and its baseline separation from major inorganic anions was achieved in CE-C(4) D using background electrolyte solution consisting of 7.5 mM L-histidine and 40 mM acetic acid at pH 4.1. The analytical method showed excellent parameters in terms of reproducibility; RSD values for migration times and peak areas at a spiked concentration of 15 μg/L of perchlorate (US EPA recommended limit for drinking water) were below 0.2 and 8.7%, respectively, in all examined water samples. Linear calibration curves were obtained for perchlorate in the concentration range 1-100 μg/L (r(2) ≥0.999) with limits of detection at 1 μg/L for tap water and at 0.25-0.35 μg/L for environmental and bottled potable water samples. Recoveries at 15 μg/L of perchlorate were between 95.9 and 106.7% with minimum and maximum recovery values for snow and bottled potable water samples, respectively.
- 650 _2
- $a kyselina octová $x chemie $7 D019342
- 650 _2
- $a chemická frakcionace $x přístrojové vybavení $x metody $7 D005591
- 650 _2
- $a elektrická vodivost $7 D004553
- 650 _2
- $a elektrolyty $x chemie $7 D004573
- 650 _2
- $a elektroforéza kapilární $x metody $7 D019075
- 650 _2
- $a heptanol $x chemie $7 D019850
- 650 _2
- $a histidin $x chemie $7 D006639
- 650 _2
- $a koncentrace vodíkových iontů $7 D006863
- 650 _2
- $a membrány umělé $7 D008567
- 650 _2
- $a perchloráty $x analýza $x izolace a purifikace $7 D010472
- 650 _2
- $a déšť $x chemie $7 D011891
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a voda $x chemie $7 D014867
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Doan, Thi Kieu Oanh
- 700 1_
- $a Kubáň, Pavel $7 jo20231190132
- 700 1_
- $a Boček, Petr, $d 1941- $7 xx0088412
- 773 0_
- $w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 32, č. 21 (2011), s. 3008-3015
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22002888 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120806 $b ABA008
- 991 __
- $a 20160321091443 $b ABA008
- 999 __
- $a ok $b bmc $g 944138 $s 779522
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 32 $c 21 $d 3008-3015 $e 20111017 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
- LZP __
- $b NLK111 $a Pubmed-20120806/12/01