-
Something wrong with this record ?
Equivalent peak resolution: characterization of the extent of separation for two components based on their relative peak overlap
M. Dvořák, J. Svobodová, P. Dubský, M. Riesová, G. Vigh, B. Gaš,
Language English Country Germany
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Electrophoresis, Capillary methods MeSH
- Normal Distribution MeSH
- Reproducibility of Results MeSH
- Software MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
Although the classical formula of peak resolution was derived to characterize the extent of separation only for Gaussian peaks of equal areas, it is often used even when the peaks follow non-Gaussian distributions and/or have unequal areas. This practice can result in misleading information about the extent of separation in terms of the severity of peak overlap. We propose here the use of the equivalent peak resolution value, a term based on relative peak overlap, to characterize the extent of separation that had been achieved. The definition of equivalent peak resolution is not constrained either by the form(s) of the concentration distribution function(s) of the peaks (Gaussian or non-Gaussian) or the relative area of the peaks. The equivalent peak resolution value and the classically defined peak resolution value are numerically identical when the separated peaks are Gaussian and have identical areas and SDs. Using our new freeware program, Resolution Analyzer, one can calculate both the classically defined and the equivalent peak resolution values. With the help of this tool, we demonstrate here that the classical peak resolution values mischaracterize the extent of peak overlap even when the peaks are Gaussian but have different areas. We show that under ideal conditions of the separation process, the relative peak overlap value is easily accessible by fitting the overall peak profile as the sum of two Gaussian functions. The applicability of the new approach is demonstrated on real separations.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16000448
- 003
- CZ-PrNML
- 005
- 20160125103832.0
- 007
- ta
- 008
- 160108s2015 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/elps.201400475 $2 doi
- 035 __
- $a (PubMed)25503084
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Dvořák, Martin $u Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University in Prague, Prague, Czech Republic.
- 245 10
- $a Equivalent peak resolution: characterization of the extent of separation for two components based on their relative peak overlap / $c M. Dvořák, J. Svobodová, P. Dubský, M. Riesová, G. Vigh, B. Gaš,
- 520 9_
- $a Although the classical formula of peak resolution was derived to characterize the extent of separation only for Gaussian peaks of equal areas, it is often used even when the peaks follow non-Gaussian distributions and/or have unequal areas. This practice can result in misleading information about the extent of separation in terms of the severity of peak overlap. We propose here the use of the equivalent peak resolution value, a term based on relative peak overlap, to characterize the extent of separation that had been achieved. The definition of equivalent peak resolution is not constrained either by the form(s) of the concentration distribution function(s) of the peaks (Gaussian or non-Gaussian) or the relative area of the peaks. The equivalent peak resolution value and the classically defined peak resolution value are numerically identical when the separated peaks are Gaussian and have identical areas and SDs. Using our new freeware program, Resolution Analyzer, one can calculate both the classically defined and the equivalent peak resolution values. With the help of this tool, we demonstrate here that the classical peak resolution values mischaracterize the extent of peak overlap even when the peaks are Gaussian but have different areas. We show that under ideal conditions of the separation process, the relative peak overlap value is easily accessible by fitting the overall peak profile as the sum of two Gaussian functions. The applicability of the new approach is demonstrated on real separations.
- 650 _2
- $a elektroforéza kapilární $x metody $7 D019075
- 650 _2
- $a normální rozdělení $7 D016011
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a software $7 D012984
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Svobodová, Jana
- 700 1_
- $a Dubský, Pavel
- 700 1_
- $a Riesová, Martina
- 700 1_
- $a Vigh, Gyula
- 700 1_
- $a Gaš, Bohuslav
- 773 0_
- $w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 36, č. 5 (2015), s. 646-54
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25503084 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160108 $b ABA008
- 991 __
- $a 20160125103954 $b ABA008
- 999 __
- $a ok $b bmc $g 1102729 $s 924654
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 36 $c 5 $d 646-54 $e 20150203 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
- LZP __
- $a Pubmed-20160108