Minimal invasive dorsal plate osteosynthesis of the tibia - are nerves and vessels at risk? An anatomical study [Minimálně invazivní osteosyntéza zlomenin tibie dorzální dlahou - jsou nervy a cévy v ohrožení? Anatomická studie]

S. Grechenig, M. Dreu, H. Clement, M. Plecko, W. Pichler, A. Gänsslen, W. Krutsch

. 2015 ; 82 (5) : 337-340.

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc16022578

PURPOSE OF THE STUDY: Purpose of this anatomic study was to develop a new and safe technique of minimal invasive dorsal plate osteosynthesis for tibia shaft fractures. MATERIAL AND METHODS: Sixteen paired adult lower limbs of eight different cadaveric specimens were examined. Anatomical prebending for each plate was done. Plates were inserted percutaneously, following plate fixation the neurovascular bundle was dissected out. The distance between the neurovascular bundle (posterior tibial nerve, posterior tibial artery) and the plate was measured at two different positions. The distance to the origin of the flexor digitorum longus muscle and the arch of the soleus muscle was measured. RESULTS: The mean distance between the neurovascular bundle and the plate amounted 1.4 cm (±0,2 cm; 1.0-1.7 cm) at hole number six and 1.1 cm (±0.4 cm; 0.6-2.0 cm) at hole number ten. The nerve was never directly in contact with the plate. The flexor digitorum longus muscle had its origin along the plate and was between the plate and the neurovascular bundle in all cases. CONCLUSIONS: Dorsal percutaneous plate insertion is a safe and easy method for osteosyntesis of tiba shaft fractures. Especially in case of poor skin and soft tissue conditions this technique offers a good alternative.

Minimálně invazivní osteosyntéza zlomenin tibie dorzální dlahou - jsou nervy a cévy v ohrožení? Anatomická studie

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16022578
003      
CZ-PrNML
005      
20160823135714.0
007      
ta
008      
160811s2015 xr a f 000 0|eng||
009      
AR
024    7_
$a 10.55095/achot2015/056 $2 doi
035    __
$a (PubMed)26516950
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Grechenig, S. $u Medical University of Regensburg, Department of Traumatology, Regensburg,Germany
245    10
$a Minimal invasive dorsal plate osteosynthesis of the tibia - are nerves and vessels at risk? An anatomical study / $c S. Grechenig, M. Dreu, H. Clement, M. Plecko, W. Pichler, A. Gänsslen, W. Krutsch
246    31
$a Minimálně invazivní osteosyntéza zlomenin tibie dorzální dlahou - jsou nervy a cévy v ohrožení? Anatomická studie
520    3_
$a PURPOSE OF THE STUDY: Purpose of this anatomic study was to develop a new and safe technique of minimal invasive dorsal plate osteosynthesis for tibia shaft fractures. MATERIAL AND METHODS: Sixteen paired adult lower limbs of eight different cadaveric specimens were examined. Anatomical prebending for each plate was done. Plates were inserted percutaneously, following plate fixation the neurovascular bundle was dissected out. The distance between the neurovascular bundle (posterior tibial nerve, posterior tibial artery) and the plate was measured at two different positions. The distance to the origin of the flexor digitorum longus muscle and the arch of the soleus muscle was measured. RESULTS: The mean distance between the neurovascular bundle and the plate amounted 1.4 cm (±0,2 cm; 1.0-1.7 cm) at hole number six and 1.1 cm (±0.4 cm; 0.6-2.0 cm) at hole number ten. The nerve was never directly in contact with the plate. The flexor digitorum longus muscle had its origin along the plate and was between the plate and the neurovascular bundle in all cases. CONCLUSIONS: Dorsal percutaneous plate insertion is a safe and easy method for osteosyntesis of tiba shaft fractures. Especially in case of poor skin and soft tissue conditions this technique offers a good alternative.
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    _2
$a kostní destičky $7 D001860
650    _2
$a mrtvola $7 D002102
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a vnitřní fixace fraktury $x škodlivé účinky $x metody $7 D005593
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a miniinvazivní chirurgické výkony $x škodlivé účinky $x metody $7 D019060
650    _2
$a poranění periferního nervu $x etiologie $x patologie $7 D059348
650    _2
$a tibie $x anatomie a histologie $7 D013977
650    _2
$a arteriae tibiales $x anatomie a histologie $x zranění $7 D016909
650    _2
$a fraktury tibie $x chirurgie $7 D013978
650    _2
$a nervus tibialis $x anatomie a histologie $x zranění $7 D013979
655    _2
$a časopisecké články $7 D016428
700    1_
$a Dreu, M. $u Medical University of Graz, Anatomie Institute, Graz, Austria
700    1_
$a Clement, H. $u Unfallkrankenhaus Graz, Graz, Austria
700    1_
$a Plecko, M. $u Unfallkrankenhaus Graz, Graz, Austria
700    1_
$a Pichler, W. $u Medical University of Regensburg, Department of Traumatology, Regensburg,Germany
700    1_
$a Gänsslen, A. $u Department of Trauma, Orthopaedics and Hand Surgery, Klinikům Wolfsburg, Wolfsburg, Germany
700    1_
$a Krutsch, W. $u Medical University of Regensburg, Department of Traumatology, Regensburg,Germany
773    0_
$w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $x 0001-5415 $g Roč. 82, č. 5 (2015), s. 337-340
910    __
$a ABA008 $b A 8 $c 507 $y 4 $z 0
990    __
$a 20160811 $b ABA008
991    __
$a 20160823140009 $b ABA008
999    __
$a ok $b bmc $g 1158905 $s 947123
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 82 $c 5 $d 337-340 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
LZP    __
$b NLK118 $a Pubmed-20160811

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...