Something wrong with this record ?
Impact Stress in Water Resistance Voice Therapy: A Physical Modeling Study
J. Horáček, V. Radolf, AM. Laukkanen,
Language English Country United States
Document type Journal Article
- MeSH
- Models, Anatomic MeSH
- Phonation * MeSH
- Vocal Cords anatomy & histology physiology MeSH
- Voice Training * MeSH
- Silicon MeSH
- Voice Quality * MeSH
- Humans MeSH
- Stress, Mechanical MeSH
- Polymethyl Methacrylate MeSH
- Pressure MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
OBJECTIVES: Phonation through a tube in water is used in voice therapy. This study investigates whether this exercise may increase mechanical loading on the vocal folds. STUDY DESIGN: This is an experimental modeling study. METHODS: A model with three-layer silicone vocal fold replica and a plexiglass, MK Plexi, Prague vocal tract set for the articulation of vowel [u:] was used. Impact stress (IS) was measured in three conditions: for [u:] (1) without a tube, (2) with a silicon Lax Vox tube (35 cm in length, 1 cm in inner diameter) immersed 2 cm in water, and (3) with the tube immersed 10 cm in water. Subglottic pressure and airflow ranges were selected to correspond to those reported in normal human phonation. RESULTS: Phonation threshold pressure was lower for phonation into water compared with [u:] without a tube. IS increased with the airflow rate. IS measured in the range of subglottic pressure, which corresponds to measurements in humans, was highest for vowel [u:] without a tube and lower with the tube in water. CONCLUSIONS: Even though the model and humans cannot be directly compared, for instance due to differences in vocal tract wall properties, the results suggest that IS is not likely to increase harmfully in water resistance therapy. However, there may be other effects related to it, possibly causing symptoms of vocal fatigue (eg, increased activity in the adductors or high amplitudes of oral pressure variation probably capable of increasing stress in the vocal fold). These need to be studied further, especially for cases where the water bubbling frequency is close to the acoustical-mechanical resonance and at the same time the fundamental phonation frequency is near the first formant frequency of the system.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20006818
- 003
- CZ-PrNML
- 005
- 20200527084040.0
- 007
- ta
- 008
- 200511s2019 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jvoice.2018.01.025 $2 doi
- 035 __
- $a (PubMed)29884510
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Horáček, Jaromír $u Institute of Thermomechanics AS CR, v.v.i., Prague 182 00, Czech Republic. Electronic address: jaromirh@it.cas.cz.
- 245 10
- $a Impact Stress in Water Resistance Voice Therapy: A Physical Modeling Study / $c J. Horáček, V. Radolf, AM. Laukkanen,
- 520 9_
- $a OBJECTIVES: Phonation through a tube in water is used in voice therapy. This study investigates whether this exercise may increase mechanical loading on the vocal folds. STUDY DESIGN: This is an experimental modeling study. METHODS: A model with three-layer silicone vocal fold replica and a plexiglass, MK Plexi, Prague vocal tract set for the articulation of vowel [u:] was used. Impact stress (IS) was measured in three conditions: for [u:] (1) without a tube, (2) with a silicon Lax Vox tube (35 cm in length, 1 cm in inner diameter) immersed 2 cm in water, and (3) with the tube immersed 10 cm in water. Subglottic pressure and airflow ranges were selected to correspond to those reported in normal human phonation. RESULTS: Phonation threshold pressure was lower for phonation into water compared with [u:] without a tube. IS increased with the airflow rate. IS measured in the range of subglottic pressure, which corresponds to measurements in humans, was highest for vowel [u:] without a tube and lower with the tube in water. CONCLUSIONS: Even though the model and humans cannot be directly compared, for instance due to differences in vocal tract wall properties, the results suggest that IS is not likely to increase harmfully in water resistance therapy. However, there may be other effects related to it, possibly causing symptoms of vocal fatigue (eg, increased activity in the adductors or high amplitudes of oral pressure variation probably capable of increasing stress in the vocal fold). These need to be studied further, especially for cases where the water bubbling frequency is close to the acoustical-mechanical resonance and at the same time the fundamental phonation frequency is near the first formant frequency of the system.
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a anatomické modely $7 D008953
- 650 12
- $a fonace $7 D010699
- 650 _2
- $a polymethylmethakrylát $7 D019904
- 650 _2
- $a tlak $7 D011312
- 650 _2
- $a křemík $7 D012825
- 650 _2
- $a mechanický stres $7 D013314
- 650 _2
- $a hlasové řasy $x anatomie a histologie $x fyziologie $7 D014827
- 650 12
- $a kvalita hlasu $7 D014833
- 650 12
- $a hlasový trénink $7 D014834
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Radolf, Vojtěch $u Institute of Thermomechanics AS CR, v.v.i., Prague 182 00, Czech Republic.
- 700 1_
- $a Laukkanen, Anne-Maria $u Speech and Voice Research Laboratory, Faculty of Education, Åkerlundink. 5, University of Tampere, Tampere 33100, Finland.
- 773 0_
- $w MED00180382 $t Journal of voice : official journal of the Voice Foundation $x 1873-4588 $g Roč. 33, č. 4 (2019), s. 490-496
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29884510 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20200511 $b ABA008
- 991 __
- $a 20200527084037 $b ABA008
- 999 __
- $a ok $b bmc $g 1525676 $s 1096874
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 33 $c 4 $d 490-496 $e 20180605 $i 1873-4588 $m Journal of voice $n J Voice $x MED00180382
- LZP __
- $a Pubmed-20200511