-
Je něco špatně v tomto záznamu ?
Mechanical properties of a biodegradable self-expandable polydioxanone monofilament stent: In vitro force relaxation and its clinical relevance
A. Bezrouk, T. Hosszu, L. Hromadko, Z. Olmrova Zmrhalova, M. Kopecek, M. Smutny, I. Selke Krulichova, JM. Macak, J. Kremlacek,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Directory of Open Access Journals
od 2006
Free Medical Journals
od 2006
Public Library of Science (PLoS)
od 2006
PubMed Central
od 2006
Europe PubMed Central
od 2006
ProQuest Central
od 2006-12-01
Open Access Digital Library
od 2006-01-01
Open Access Digital Library
od 2006-10-01
Open Access Digital Library
od 2006-01-01
Medline Complete (EBSCOhost)
od 2008-01-01
Nursing & Allied Health Database (ProQuest)
od 2006-12-01
Health & Medicine (ProQuest)
od 2006-12-01
Public Health Database (ProQuest)
od 2006-12-01
ROAD: Directory of Open Access Scholarly Resources
od 2006
- MeSH
- biokompatibilní materiály chemie MeSH
- lidé MeSH
- mechanické jevy MeSH
- modul pružnosti MeSH
- polydioxanon chemie MeSH
- protézy - design MeSH
- stenty * MeSH
- testování materiálů MeSH
- vstřebatelné implantáty * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Biodegradable stents are promising treatments for many diseases, e.g., coronary artery disease, urethral diseases, tracheal diseases, and esophageal strictures. The mechanical properties of biodegradable stent materials play a key role in the safety and efficacy of treatment. In particular, insufficient creep resistance of the stent material could result in premature stent collapse or narrowing. Commercially available biodegradable self-expandable SX-ELLA stents made of polydioxanone monofilament were tested. A new, simple, and affordable method to measure the shear modulus of tiny viscoelastic wires is presented. The important mechanical parameters of the polydioxanone filament were obtained: the median Young's modulus was [Formula: see text] = 958 (922, 974) MPa and the shear modulus was [Formula: see text] = 357 (185, 387) MPa, resulting in a Poisson's ratio of ν = 0.34. The SX-ELLA stents exhibited significant force relaxation due to the stress relaxation of the polydioxanone monofilament, approximately 19% and 36% 10 min and 48 h after stent application, respectively. However, these results were expected, and the manufacturer and implanting clinician should be aware of the known behavior of these biodegradable materials. If possible, a biodegradable stent should be designed considering therapeutic force rather than initial force. Additionally, new and more advanced biodegradable shape-memory polymers should be considered for future study and use.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20024894
- 003
- CZ-PrNML
- 005
- 20230428085544.0
- 007
- ta
- 008
- 201125s2020 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1371/journal.pone.0235842 $2 doi
- 035 __
- $a (PubMed)32639989
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Bezrouk, Ales $u Department of Medical Biophysics, Faculty of Medicine in Hradec Kralove, Charles University, Hradec Kralove, Czech Republic.
- 245 10
- $a Mechanical properties of a biodegradable self-expandable polydioxanone monofilament stent: In vitro force relaxation and its clinical relevance / $c A. Bezrouk, T. Hosszu, L. Hromadko, Z. Olmrova Zmrhalova, M. Kopecek, M. Smutny, I. Selke Krulichova, JM. Macak, J. Kremlacek,
- 520 9_
- $a Biodegradable stents are promising treatments for many diseases, e.g., coronary artery disease, urethral diseases, tracheal diseases, and esophageal strictures. The mechanical properties of biodegradable stent materials play a key role in the safety and efficacy of treatment. In particular, insufficient creep resistance of the stent material could result in premature stent collapse or narrowing. Commercially available biodegradable self-expandable SX-ELLA stents made of polydioxanone monofilament were tested. A new, simple, and affordable method to measure the shear modulus of tiny viscoelastic wires is presented. The important mechanical parameters of the polydioxanone filament were obtained: the median Young's modulus was [Formula: see text] = 958 (922, 974) MPa and the shear modulus was [Formula: see text] = 357 (185, 387) MPa, resulting in a Poisson's ratio of ν = 0.34. The SX-ELLA stents exhibited significant force relaxation due to the stress relaxation of the polydioxanone monofilament, approximately 19% and 36% 10 min and 48 h after stent application, respectively. However, these results were expected, and the manufacturer and implanting clinician should be aware of the known behavior of these biodegradable materials. If possible, a biodegradable stent should be designed considering therapeutic force rather than initial force. Additionally, new and more advanced biodegradable shape-memory polymers should be considered for future study and use.
- 650 12
- $a vstřebatelné implantáty $7 D020341
- 650 _2
- $a biokompatibilní materiály $x chemie $7 D001672
- 650 _2
- $a modul pružnosti $7 D055119
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a testování materiálů $7 D008422
- 650 _2
- $a mechanické jevy $7 D055595
- 650 _2
- $a polydioxanon $x chemie $7 D016687
- 650 _2
- $a protézy - design $7 D011474
- 650 12
- $a stenty $7 D015607
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Hosszu, Tomas $u Department of Neurosurgery, University Hospital Hradec Kralove, Hradec Kralove, Czech Republic.
- 700 1_
- $a Hromadko, Ludek $u Center of Materials and Nanotechnologies, Faculty of Chemical Technology, University of Pardubice, Pardubice, Czech Republic. Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic.
- 700 1_
- $a Olmrova Zmrhalova, Zuzana $u Center of Materials and Nanotechnologies, Faculty of Chemical Technology, University of Pardubice, Pardubice, Czech Republic.
- 700 1_
- $a Kopecek, Martin $u Department of Medical Biophysics, Faculty of Medicine in Hradec Kralove, Charles University, Hradec Kralove, Czech Republic.
- 700 1_
- $a Smutný, Martin, $u Department of Medical Biophysics, Faculty of Medicine in Hradec Kralove, Charles University, Hradec Kralove, Czech Republic. $d 1989- $7 xx0300942
- 700 1_
- $a Selke Krulichova, Iva $u Department of Medical Biophysics, Faculty of Medicine in Hradec Kralove, Charles University, Hradec Kralove, Czech Republic.
- 700 1_
- $a Macák, Jan, $u Center of Materials and Nanotechnologies, Faculty of Chemical Technology, University of Pardubice, Pardubice, Czech Republic. Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic. $d 1979- $7 xx0277890
- 700 1_
- $a Kremlacek, Jan $u Department of Medical Biophysics, Faculty of Medicine in Hradec Kralove, Charles University, Hradec Kralove, Czech Republic.
- 773 0_
- $w MED00180950 $t PloS one $x 1932-6203 $g Roč. 15, č. 7 (2020), s. e0235842
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32639989 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20201125 $b ABA008
- 991 __
- $a 20230428085537 $b ABA008
- 999 __
- $a ok $b bmc $g 1599039 $s 1115580
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 15 $c 7 $d e0235842 $e 20200708 $i 1932-6203 $m PLoS One $n PLoS One $x MED00180950
- LZP __
- $a Pubmed-20201125