• Something wrong with this record ?

Non-invasive assessment of arterial pulsatility in patients with continuous-flow left ventricular assist devices

TJ. Cross, P. Sajgalik, V. Fabian, L. Matera, SS. Kushwaha, S. Maltais, JM. Stulak, JA. Schirger, BD. Johnson,

. 2020 ; 43 (2) : 99-108. [pub] 20190814

Language English Country United States

Document type Journal Article

INTRODUCTION: Long-term use of continuous-flow left ventricular assist devices may have negative consequences for autonomic, cardiovascular and gastrointestinal function. It has thus been suggested that non-invasive monitoring of arterial pulsatility in patients with a left ventricular assist device is highly important for ensuring patient safety and longevity. We have developed a novel, semi-automated frequency-domain-based index of arterial pulsatility that is obtained during suprasystolic occlusions of the upper arm: the 'cuff pulsatility index'. PURPOSE: The purpose of this study was to evaluate the relationship between the cuff pulsatility index and invasively determined arterial pulsatility in patients with a left ventricular assist device. METHODS: Twenty-three patients with a left ventricular assist device with end-stage heart failure (six females: age = 65 ± 9 years; body mass index = 30.5 ± 3.7 kg m-2) were recruited for this study. Suprasystolic occlusions were performed on the upper arm of the patient's dominant side, from which the cuff pressure waveform was obtained. Arterial blood pressure was obtained from the radial artery on the contralateral arm. Measurements were obtained in triplicate. The relationship between the cuff pressure and arterial blood pressure waveforms was assessed in the frequency-domain using coherence analysis. A mixed-effects approach was used to assess the relationship between cuff pulsatility index and invasively determined arterial pulsatility (i.e. pulse pressure). RESULTS: The cuff pressure and arterial blood pressure waveforms demonstrated a high coherence up to the fifth harmonic of the cardiac frequency (heart rate). The cuff pulsatility index accurately tracked changes in arterial pulse pressure within a given patient across repeated measurements. CONCLUSIONS: The cuff pulsatility index shows promise as a non-invasive index for monitoring residual arterial pulsatility in patients with a left ventricular assist device across time.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20025232
003      
CZ-PrNML
005      
20201222155125.0
007      
ta
008      
201125s2020 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1177/0391398819868236 $2 doi
035    __
$a (PubMed)31411101
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Cross, Troy J $u Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA. Menzies Health Institute Queensland, Griffith University, Southport, QLD, Australia.
245    10
$a Non-invasive assessment of arterial pulsatility in patients with continuous-flow left ventricular assist devices / $c TJ. Cross, P. Sajgalik, V. Fabian, L. Matera, SS. Kushwaha, S. Maltais, JM. Stulak, JA. Schirger, BD. Johnson,
520    9_
$a INTRODUCTION: Long-term use of continuous-flow left ventricular assist devices may have negative consequences for autonomic, cardiovascular and gastrointestinal function. It has thus been suggested that non-invasive monitoring of arterial pulsatility in patients with a left ventricular assist device is highly important for ensuring patient safety and longevity. We have developed a novel, semi-automated frequency-domain-based index of arterial pulsatility that is obtained during suprasystolic occlusions of the upper arm: the 'cuff pulsatility index'. PURPOSE: The purpose of this study was to evaluate the relationship between the cuff pulsatility index and invasively determined arterial pulsatility in patients with a left ventricular assist device. METHODS: Twenty-three patients with a left ventricular assist device with end-stage heart failure (six females: age = 65 ± 9 years; body mass index = 30.5 ± 3.7 kg m-2) were recruited for this study. Suprasystolic occlusions were performed on the upper arm of the patient's dominant side, from which the cuff pressure waveform was obtained. Arterial blood pressure was obtained from the radial artery on the contralateral arm. Measurements were obtained in triplicate. The relationship between the cuff pressure and arterial blood pressure waveforms was assessed in the frequency-domain using coherence analysis. A mixed-effects approach was used to assess the relationship between cuff pulsatility index and invasively determined arterial pulsatility (i.e. pulse pressure). RESULTS: The cuff pressure and arterial blood pressure waveforms demonstrated a high coherence up to the fifth harmonic of the cardiac frequency (heart rate). The cuff pulsatility index accurately tracked changes in arterial pulse pressure within a given patient across repeated measurements. CONCLUSIONS: The cuff pulsatility index shows promise as a non-invasive index for monitoring residual arterial pulsatility in patients with a left ventricular assist device across time.
650    _2
$a senioři $7 D000368
650    _2
$a arterie $x patofyziologie $7 D001158
650    _2
$a asistovaná cirkulace $x přístrojové vybavení $x metody $7 D001243
650    _2
$a krevní tlak $x fyziologie $7 D001794
650    _2
$a diagnostické techniky kardiovaskulární $7 D003935
650    _2
$a ženské pohlaví $7 D005260
650    12
$a srdeční selhání $x patofyziologie $x terapie $7 D006333
650    12
$a podpůrné srdeční systémy $7 D006353
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a pulzatilní průtok $x fyziologie $7 D011673
650    _2
$a pulz $x metody $7 D011674
650    _2
$a reprodukovatelnost výsledků $7 D015203
655    _2
$a časopisecké články $7 D016428
700    1_
$a Sajgalik, Pavol $u Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA.
700    1_
$a Fabian, Vratislav $u Department of Physics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic.
700    1_
$a Matera, Lukas $u Department of Physics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic.
700    1_
$a Kushwaha, Sudhir S $u Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA.
700    1_
$a Maltais, Simon $u Department of Cardiovascular Surgery, Mayo Clinic, Rochester, MN, USA.
700    1_
$a Stulak, John M $u Department of Cardiovascular Surgery, Mayo Clinic, Rochester, MN, USA.
700    1_
$a Schirger, John A $u Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA.
700    1_
$a Johnson, Bruce D $u Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA.
773    0_
$w MED00002289 $t The International journal of artificial organs $x 1724-6040 $g Roč. 43, č. 2 (2020), s. 99-108
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31411101 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20201125 $b ABA008
991    __
$a 20201222155121 $b ABA008
999    __
$a ok $b bmc $g 1599377 $s 1115918
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 43 $c 2 $d 99-108 $e 20190814 $i 1724-6040 $m The International Journal of Artificial Organs $n Int. J. Artif. Organs (Testo stamp.) $x MED00002289
LZP    __
$a Pubmed-20201125

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...