Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Electrical Source Imaging in Freely Moving Rats: Evaluation of a 12-Electrode Cortical Electroencephalography System

S. Jiricek, V. Koudelka, J. Lacik, C. Vejmola, D. Kuratko, DK. Wójcik, Z. Raida, J. Hlinka, T. Palenicek

. 2020 ; 14 (-) : 589228. [pub] 20210125

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc21010609

This work presents and evaluates a 12-electrode intracranial electroencephalography system developed at the National Institute of Mental Health (Klecany, Czech Republic) in terms of an electrical source imaging (ESI) technique in rats. The electrode system was originally designed for translational research purposes. This study demonstrates that it is also possible to use this well-established system for ESI, and estimates its precision, accuracy, and limitations. Furthermore, this paper sets a methodological basis for future implants. Source localization quality is evaluated using three approaches based on surrogate data, physical phantom measurements, and in vivo experiments. The forward model for source localization is obtained from the FieldTrip-SimBio pipeline using the finite-element method. Rat brain tissue extracted from a magnetic resonance imaging template is approximated by a single-compartment homogeneous tetrahedral head model. Four inverse solvers were tested: standardized low-resolution brain electromagnetic tomography, exact low-resolution brain electromagnetic tomography (eLORETA), linear constrained minimum variance (LCMV), and dynamic imaging of coherent sources. Based on surrogate data, this paper evaluates the accuracy and precision of all solvers within the brain volume using error distance and reliability maps. The mean error distance over the whole brain was found to be the lowest in the eLORETA solution through signal to noise ratios (SNRs) (0.2 mm for 25 dB SNR). The LCMV outperformed eLORETA under higher SNR conditions, and exhibiting higher spatial precision. Both of these inverse solvers provided accurate results in a phantom experiment (1.6 mm mean error distance across shallow and 2.6 mm across subcortical testing dipoles). Utilizing the developed technique in freely moving rats, an auditory steady-state response experiment provided results in line with previously reported findings. The obtained results support the idea of utilizing a 12-electrode system for ESI and using it as a solid basis for the development of future ESI dedicated implants.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21010609
003      
CZ-PrNML
005      
20210715154640.0
007      
ta
008      
210413s2020 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3389/fninf.2020.589228 $2 doi
035    __
$a (PubMed)33568980
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Jiricek, Stanislav $u National Institute of Mental Health, Klecany, Czechia ; Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czechia ; Department of Complex Systems, Institute of Computer Science of the Czech Academy of Sciences, Prague, Czechia
245    10
$a Electrical Source Imaging in Freely Moving Rats: Evaluation of a 12-Electrode Cortical Electroencephalography System / $c S. Jiricek, V. Koudelka, J. Lacik, C. Vejmola, D. Kuratko, DK. Wójcik, Z. Raida, J. Hlinka, T. Palenicek
520    9_
$a This work presents and evaluates a 12-electrode intracranial electroencephalography system developed at the National Institute of Mental Health (Klecany, Czech Republic) in terms of an electrical source imaging (ESI) technique in rats. The electrode system was originally designed for translational research purposes. This study demonstrates that it is also possible to use this well-established system for ESI, and estimates its precision, accuracy, and limitations. Furthermore, this paper sets a methodological basis for future implants. Source localization quality is evaluated using three approaches based on surrogate data, physical phantom measurements, and in vivo experiments. The forward model for source localization is obtained from the FieldTrip-SimBio pipeline using the finite-element method. Rat brain tissue extracted from a magnetic resonance imaging template is approximated by a single-compartment homogeneous tetrahedral head model. Four inverse solvers were tested: standardized low-resolution brain electromagnetic tomography, exact low-resolution brain electromagnetic tomography (eLORETA), linear constrained minimum variance (LCMV), and dynamic imaging of coherent sources. Based on surrogate data, this paper evaluates the accuracy and precision of all solvers within the brain volume using error distance and reliability maps. The mean error distance over the whole brain was found to be the lowest in the eLORETA solution through signal to noise ratios (SNRs) (0.2 mm for 25 dB SNR). The LCMV outperformed eLORETA under higher SNR conditions, and exhibiting higher spatial precision. Both of these inverse solvers provided accurate results in a phantom experiment (1.6 mm mean error distance across shallow and 2.6 mm across subcortical testing dipoles). Utilizing the developed technique in freely moving rats, an auditory steady-state response experiment provided results in line with previously reported findings. The obtained results support the idea of utilizing a 12-electrode system for ESI and using it as a solid basis for the development of future ESI dedicated implants.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Koudelka, Vlastimil $u National Institute of Mental Health, Klecany, Czechia
700    1_
$a Lacik, Jaroslav $u Department of Radioengineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czechia
700    1_
$a Vejmola, Cestmir $u National Institute of Mental Health, Klecany, Czechia ; Third Faculty of Medicine, Charles University, Prague, Czechia
700    1_
$a Kuratko, David $u Department of Radioengineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czechia
700    1_
$a Wójcik, Daniel K $u Department of Radioengineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czechia ; Laboratory of Neuroinformatics, Nencki Institute of Experimental Biology of the Polish Academy of Sciences, Warsaw, Poland
700    1_
$a Raida, Zbynek $u Department of Radioengineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czechia
700    1_
$a Hlinka, Jaroslav $u National Institute of Mental Health, Klecany, Czechia ; Department of Complex Systems, Institute of Computer Science of the Czech Academy of Sciences, Prague, Czechia
700    1_
$a Palenicek, Tomas $u National Institute of Mental Health, Klecany, Czechia ; Third Faculty of Medicine, Charles University, Prague, Czechia
773    0_
$w MED00174553 $t Frontiers in neuroinformatics $x 1662-5196 $g Roč. 14, č. - (2020), s. 589228
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33568980 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20210413 $b ABA008
991    __
$a 20210715154639 $b ABA008
999    __
$a ind $b bmc $g 1649878 $s 1130985
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 14 $c - $d 589228 $e 20210125 $i 1662-5196 $m Frontiers in neuroinformatics $n Front. neuroinform. $x MED00174553
LZP    __
$a Pubmed-20210413

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...