• Je něco špatně v tomto záznamu ?

Electromechanical impedance measurements for bone health monitoring through teeth used as probes of a Piezo-device

CI. Cardona, HA. Tinoco, MLF. Marín-Berrio, J. García-Grisales, JP. Gomez, SI. Roldan-Restrepo, J. Ortiz-Jimenez

. 2020 ; 7 (1) : . [pub] 20201123

Jazyk angličtina Země Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc22004807

Bone is a dynamic biological tissue that acts as the primary rigid support of the body. Several systemic factors are responsible for pathologies that negatively affect its structural attributes. Although the bone is in continuous renewal by osteogenesis, metabolic diseases are the most common affectations that alter its natural equilibrium. Different techniques based on ionizing radiation are used for the bone diagnosis restrictively. However, if these are not used adequately, the application could present risks for human health. In this paper, it is proposed and explored a new technique to apply an early-stage diagnosis of bone variations. The technique evaluates bone structural conditions from the teeth (used as probes) by applying a structural health monitoring (SHM) methodology. An experimental procedure is described to identify the stiffness variations produced by mechanical drillings done in prepared bone samples. The identification is carried out applying the electromechanical impedance technique (EMI) through a piezo-actuated device in the frequency spectrum 5-20kHz. Three bone samples with incorporated teeth (three teeth, two teeth, and one tooth) were prepared to emulate a mandibular portion of alveolar bone-PDL (periodontal ligament)-tooth system. Piezo-device was attached to the crown of the tooth with an orthodontic bracket allowing the teeth to act as probes. The electrical resistance measurements were computed with an electrical decoupling approach that improved the detection of the drillings; it was due to the increment of the sensitivity of the signals. The results showed that the bone mass reduction is correlated with statistical indices obtained in specific frequency intervals of the electrical resistance. This work suggests the possibility of a future application addressed to a bone diagnosis in a non-invasive way.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22004807
003      
CZ-PrNML
005      
20220127144944.0
007      
ta
008      
220113s2020 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1088/2057-1976/abc099 $2 doi
035    __
$a (PubMed)34037537
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Cardona, Carlos I $u Experimental and Computational Mechanics Laboratory, Universidad Autónoma de Manizales. Antigua Estación del Ferrocarril, Edificio Fundadores, P.C. 170001. Manizales, Colombia
245    10
$a Electromechanical impedance measurements for bone health monitoring through teeth used as probes of a Piezo-device / $c CI. Cardona, HA. Tinoco, MLF. Marín-Berrio, J. García-Grisales, JP. Gomez, SI. Roldan-Restrepo, J. Ortiz-Jimenez
520    9_
$a Bone is a dynamic biological tissue that acts as the primary rigid support of the body. Several systemic factors are responsible for pathologies that negatively affect its structural attributes. Although the bone is in continuous renewal by osteogenesis, metabolic diseases are the most common affectations that alter its natural equilibrium. Different techniques based on ionizing radiation are used for the bone diagnosis restrictively. However, if these are not used adequately, the application could present risks for human health. In this paper, it is proposed and explored a new technique to apply an early-stage diagnosis of bone variations. The technique evaluates bone structural conditions from the teeth (used as probes) by applying a structural health monitoring (SHM) methodology. An experimental procedure is described to identify the stiffness variations produced by mechanical drillings done in prepared bone samples. The identification is carried out applying the electromechanical impedance technique (EMI) through a piezo-actuated device in the frequency spectrum 5-20kHz. Three bone samples with incorporated teeth (three teeth, two teeth, and one tooth) were prepared to emulate a mandibular portion of alveolar bone-PDL (periodontal ligament)-tooth system. Piezo-device was attached to the crown of the tooth with an orthodontic bracket allowing the teeth to act as probes. The electrical resistance measurements were computed with an electrical decoupling approach that improved the detection of the drillings; it was due to the increment of the sensitivity of the signals. The results showed that the bone mass reduction is correlated with statistical indices obtained in specific frequency intervals of the electrical resistance. This work suggests the possibility of a future application addressed to a bone diagnosis in a non-invasive way.
650    12
$a kostní denzita $7 D015519
650    _2
$a elektrická impedance $7 D017097
650    _2
$a lidé $7 D006801
650    _2
$a mandibula $x diagnostické zobrazování $7 D008334
650    _2
$a periodontální vaz $7 D010513
650    12
$a zuby $x diagnostické zobrazování $7 D014070
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Tinoco, Hector A $u Experimental and Computational Mechanics Laboratory, Universidad Autónoma de Manizales. Antigua Estación del Ferrocarril, Edificio Fundadores, P.C. 170001. Manizales, Colombia $u Institute of Physics of Materials, Sciences Academy of Czech Republic, Žižkova 22, 616 62 Brno, Czech Republic $u Central European Institute of Technology - Brno University of Technology, Technická 3058/10, 61600 Brno, Czech Republic
700    1_
$a Marín-Berrio, Maribel L F $u Department of Health, Universidad Autónoma de Manizales, Antigua Estación del Ferrocarril, Edificio Sacatín P.C. 170001. Manizales, Colombia
700    1_
$a García-Grisales, Juliana $u Department of Health, Universidad Autónoma de Manizales, Antigua Estación del Ferrocarril, Edificio Sacatín P.C. 170001. Manizales, Colombia
700    1_
$a Gomez, Juan P $u Department of Health, Universidad Autónoma de Manizales, Antigua Estación del Ferrocarril, Edificio Sacatín P.C. 170001. Manizales, Colombia
700    1_
$a Roldan-Restrepo, Samuel I $u Centro de Innovación Roldan, Cl 4 Sur 43 Aa 26 Oficina 306, Medellin-Antioquia, Colombia
700    1_
$a Ortiz-Jimenez, Juliana $u Experimental and Computational Mechanics Laboratory, Universidad Autónoma de Manizales. Antigua Estación del Ferrocarril, Edificio Fundadores, P.C. 170001. Manizales, Colombia
773    0_
$w MED00208693 $t Biomedical physics & engineering express $x 2057-1976 $g Roč. 7, č. 1 (2020)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34037537 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20220127144941 $b ABA008
999    __
$a ok $b bmc $g 1752105 $s 1155956
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 7 $c 1 $e 20201123 $i 2057-1976 $m Biomedical physics & engineering express $n Biomed Phys Eng Express $x MED00208693
LZP    __
$a Pubmed-20220113

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...