Electromechanical impedance measurements for bone health monitoring through teeth used as probes of a Piezo-device
CI. Cardona, HA. Tinoco, MLF. Marín-Berrio, J. García-Grisales, JP. Gomez, SI. Roldan-Restrepo, J. Ortiz-Jimenez
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
34037537
DOI
10.1088/2057-1976/abc099
Knihovny.cz E-zdroje
- MeSH
- elektrická impedance MeSH
- kostní denzita * MeSH
- lidé MeSH
- mandibula diagnostické zobrazování MeSH
- periodontální vaz MeSH
- zuby * diagnostické zobrazování MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Bone is a dynamic biological tissue that acts as the primary rigid support of the body. Several systemic factors are responsible for pathologies that negatively affect its structural attributes. Although the bone is in continuous renewal by osteogenesis, metabolic diseases are the most common affectations that alter its natural equilibrium. Different techniques based on ionizing radiation are used for the bone diagnosis restrictively. However, if these are not used adequately, the application could present risks for human health. In this paper, it is proposed and explored a new technique to apply an early-stage diagnosis of bone variations. The technique evaluates bone structural conditions from the teeth (used as probes) by applying a structural health monitoring (SHM) methodology. An experimental procedure is described to identify the stiffness variations produced by mechanical drillings done in prepared bone samples. The identification is carried out applying the electromechanical impedance technique (EMI) through a piezo-actuated device in the frequency spectrum 5-20kHz. Three bone samples with incorporated teeth (three teeth, two teeth, and one tooth) were prepared to emulate a mandibular portion of alveolar bone-PDL (periodontal ligament)-tooth system. Piezo-device was attached to the crown of the tooth with an orthodontic bracket allowing the teeth to act as probes. The electrical resistance measurements were computed with an electrical decoupling approach that improved the detection of the drillings; it was due to the increment of the sensitivity of the signals. The results showed that the bone mass reduction is correlated with statistical indices obtained in specific frequency intervals of the electrical resistance. This work suggests the possibility of a future application addressed to a bone diagnosis in a non-invasive way.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22004807
- 003
- CZ-PrNML
- 005
- 20220127144944.0
- 007
- ta
- 008
- 220113s2020 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1088/2057-1976/abc099 $2 doi
- 035 __
- $a (PubMed)34037537
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Cardona, Carlos I $u Experimental and Computational Mechanics Laboratory, Universidad Autónoma de Manizales. Antigua Estación del Ferrocarril, Edificio Fundadores, P.C. 170001. Manizales, Colombia
- 245 10
- $a Electromechanical impedance measurements for bone health monitoring through teeth used as probes of a Piezo-device / $c CI. Cardona, HA. Tinoco, MLF. Marín-Berrio, J. García-Grisales, JP. Gomez, SI. Roldan-Restrepo, J. Ortiz-Jimenez
- 520 9_
- $a Bone is a dynamic biological tissue that acts as the primary rigid support of the body. Several systemic factors are responsible for pathologies that negatively affect its structural attributes. Although the bone is in continuous renewal by osteogenesis, metabolic diseases are the most common affectations that alter its natural equilibrium. Different techniques based on ionizing radiation are used for the bone diagnosis restrictively. However, if these are not used adequately, the application could present risks for human health. In this paper, it is proposed and explored a new technique to apply an early-stage diagnosis of bone variations. The technique evaluates bone structural conditions from the teeth (used as probes) by applying a structural health monitoring (SHM) methodology. An experimental procedure is described to identify the stiffness variations produced by mechanical drillings done in prepared bone samples. The identification is carried out applying the electromechanical impedance technique (EMI) through a piezo-actuated device in the frequency spectrum 5-20kHz. Three bone samples with incorporated teeth (three teeth, two teeth, and one tooth) were prepared to emulate a mandibular portion of alveolar bone-PDL (periodontal ligament)-tooth system. Piezo-device was attached to the crown of the tooth with an orthodontic bracket allowing the teeth to act as probes. The electrical resistance measurements were computed with an electrical decoupling approach that improved the detection of the drillings; it was due to the increment of the sensitivity of the signals. The results showed that the bone mass reduction is correlated with statistical indices obtained in specific frequency intervals of the electrical resistance. This work suggests the possibility of a future application addressed to a bone diagnosis in a non-invasive way.
- 650 12
- $a kostní denzita $7 D015519
- 650 _2
- $a elektrická impedance $7 D017097
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mandibula $x diagnostické zobrazování $7 D008334
- 650 _2
- $a periodontální vaz $7 D010513
- 650 12
- $a zuby $x diagnostické zobrazování $7 D014070
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Tinoco, Hector A $u Experimental and Computational Mechanics Laboratory, Universidad Autónoma de Manizales. Antigua Estación del Ferrocarril, Edificio Fundadores, P.C. 170001. Manizales, Colombia $u Institute of Physics of Materials, Sciences Academy of Czech Republic, Žižkova 22, 616 62 Brno, Czech Republic $u Central European Institute of Technology - Brno University of Technology, Technická 3058/10, 61600 Brno, Czech Republic
- 700 1_
- $a Marín-Berrio, Maribel L F $u Department of Health, Universidad Autónoma de Manizales, Antigua Estación del Ferrocarril, Edificio Sacatín P.C. 170001. Manizales, Colombia
- 700 1_
- $a García-Grisales, Juliana $u Department of Health, Universidad Autónoma de Manizales, Antigua Estación del Ferrocarril, Edificio Sacatín P.C. 170001. Manizales, Colombia
- 700 1_
- $a Gomez, Juan P $u Department of Health, Universidad Autónoma de Manizales, Antigua Estación del Ferrocarril, Edificio Sacatín P.C. 170001. Manizales, Colombia
- 700 1_
- $a Roldan-Restrepo, Samuel I $u Centro de Innovación Roldan, Cl 4 Sur 43 Aa 26 Oficina 306, Medellin-Antioquia, Colombia
- 700 1_
- $a Ortiz-Jimenez, Juliana $u Experimental and Computational Mechanics Laboratory, Universidad Autónoma de Manizales. Antigua Estación del Ferrocarril, Edificio Fundadores, P.C. 170001. Manizales, Colombia
- 773 0_
- $w MED00208693 $t Biomedical physics & engineering express $x 2057-1976 $g Roč. 7, č. 1 (2020)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34037537 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220113 $b ABA008
- 991 __
- $a 20220127144941 $b ABA008
- 999 __
- $a ok $b bmc $g 1752105 $s 1155956
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 7 $c 1 $e 20201123 $i 2057-1976 $m Biomedical physics & engineering express $n Biomed Phys Eng Express $x MED00208693
- LZP __
- $a Pubmed-20220113