The article introduces the remote ECG data collecting system. The system consists of a one-lead ECG device connectable via USB to a smartphone, an Android application, a server, and a web application. The ECG device is designed as a USB dongle with small dimensions and uses On-the-Go (OTG) powering technique. These features classify the developed device as wearables. The measured ECG data are stored in the smartphone's internal memory and transmitted to the remote biobank server at predefined time intervals for archiving and subsequent processing. The functionality of Android and the web application are also described in the article. Both applications have a user-friendly graphical user interface. The proposed system was tested in two scenarios: ECG measured on the patient simulator and living subject. The measured raw ECG signals are suitable for basic diagnostics of cardiac health and confirmed the correct function of the proposed system.
References provided by Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc23006773
- 003
- CZ-PrNML
- 005
- 20230926121753.0
- 007
- ta
- 008
- 230522s2021 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.14311/CTJ.2021.1.08 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Babušiak, Branko, $d 1983- $7 mzk2007390332 $u Department of Electromagnetic and Biomedical Engineering, FEIT, University of Zilina
- 245 10
- $a Design of ECG system for remote data collection / $c Branko Babušiak, Maroš Šmondrk, Ladislav Janoušek
- 504 __
- $a Literatura
- 520 9_
- $a The article introduces the remote ECG data collecting system. The system consists of a one-lead ECG device connectable via USB to a smartphone, an Android application, a server, and a web application. The ECG device is designed as a USB dongle with small dimensions and uses On-the-Go (OTG) powering technique. These features classify the developed device as wearables. The measured ECG data are stored in the smartphone's internal memory and transmitted to the remote biobank server at predefined time intervals for archiving and subsequent processing. The functionality of Android and the web application are also described in the article. Both applications have a user-friendly graphical user interface. The proposed system was tested in two scenarios: ECG measured on the patient simulator and living subject. The measured raw ECG signals are suitable for basic diagnostics of cardiac health and confirmed the correct function of the proposed system.
- 650 17
- $a elektrokardiografie $x metody $x přístrojové vybavení $7 D004562 $2 czmesh
- 650 _7
- $a mobilní aplikace $x klasifikace $x trendy $7 D063731 $2 czmesh
- 650 _7
- $a chytrý telefon $x přístrojové vybavení $7 D000068997 $2 czmesh
- 650 _7
- $a počítačové komunikační sítě $x trendy $7 D003195 $2 czmesh
- 650 _7
- $a počítače $7 D003201 $2 czmesh
- 650 _7
- $a kardiovaskulární nemoci $x diagnostické zobrazování $x patofyziologie $x prevence a kontrola $7 D002318 $2 czmesh
- 650 _7
- $a banky biologického materiálu $7 D018070 $2 czmesh
- 650 _7
- $a automatizované zpracování dat $x metody $7 D001330 $2 czmesh
- 650 _7
- $a biomedicínský výzkum $7 D035843 $2 czmesh
- 655 _7
- $a práce podpořená grantem $7 D013485 $2 czmesh
- 655 _7
- $a přehledy $7 D016454 $2 czmesh
- 700 1_
- $a Šmondrk, Maroš $7 xx0242516 $u Department of Electromagnetic and Biomedical Engineering, FEIT, University of Zilina
- 700 1_
- $a Janoušek, Ladislav $7 mzk2008448709 $u Department of Electromagnetic and Biomedical Engineering, FEIT, University of Zilina
- 773 0_
- $t Lékař a technika $x 0301-5491 $g Roč. 51, č. 1-4 (2021), s. 53-58 $w MED00011033
- 910 __
- $a ABA008 $b B 1367 $c 1071 b $y p $z 0
- 990 __
- $a 20230517141648 $b ABA008
- 991 __
- $a 20230926121751 $b ABA008
- 999 __
- $a ok $b bmc $g 1935589 $s 1192997
- BAS __
- $a 3
- BMC __
- $a 2021 $b 51 $c 1-4 $d 53-58 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
- LZP __
- $c NLK193 $d 20230926 $a NLK 2023-16/kv