• Something wrong with this record ?

Design of ECG system for remote data collection

Branko Babušiak, Maroš Šmondrk, Ladislav Janoušek

. 2021 ; 51 (1-4) : 53-58.

Language English Country Czech Republic

Document type Research Support, Non-U.S. Gov't, Review

The article introduces the remote ECG data collecting system. The system consists of a one-lead ECG device connectable via USB to a smartphone, an Android application, a server, and a web application. The ECG device is designed as a USB dongle with small dimensions and uses On-the-Go (OTG) powering technique. These features classify the developed device as wearables. The measured ECG data are stored in the smartphone's internal memory and transmitted to the remote biobank server at predefined time intervals for archiving and subsequent processing. The functionality of Android and the web application are also described in the article. Both applications have a user-friendly graphical user interface. The proposed system was tested in two scenarios: ECG measured on the patient simulator and living subject. The measured raw ECG signals are suitable for basic diagnostics of cardiac health and confirmed the correct function of the proposed system.

References provided by Crossref.org

Bibliography, etc.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc23006773
003      
CZ-PrNML
005      
20230926121753.0
007      
ta
008      
230522s2021 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.14311/CTJ.2021.1.08 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Babušiak, Branko, $d 1983- $7 mzk2007390332 $u Department of Electromagnetic and Biomedical Engineering, FEIT, University of Zilina
245    10
$a Design of ECG system for remote data collection / $c Branko Babušiak, Maroš Šmondrk, Ladislav Janoušek
504    __
$a Literatura
520    9_
$a The article introduces the remote ECG data collecting system. The system consists of a one-lead ECG device connectable via USB to a smartphone, an Android application, a server, and a web application. The ECG device is designed as a USB dongle with small dimensions and uses On-the-Go (OTG) powering technique. These features classify the developed device as wearables. The measured ECG data are stored in the smartphone's internal memory and transmitted to the remote biobank server at predefined time intervals for archiving and subsequent processing. The functionality of Android and the web application are also described in the article. Both applications have a user-friendly graphical user interface. The proposed system was tested in two scenarios: ECG measured on the patient simulator and living subject. The measured raw ECG signals are suitable for basic diagnostics of cardiac health and confirmed the correct function of the proposed system.
650    17
$a elektrokardiografie $x metody $x přístrojové vybavení $7 D004562 $2 czmesh
650    _7
$a mobilní aplikace $x klasifikace $x trendy $7 D063731 $2 czmesh
650    _7
$a chytrý telefon $x přístrojové vybavení $7 D000068997 $2 czmesh
650    _7
$a počítačové komunikační sítě $x trendy $7 D003195 $2 czmesh
650    _7
$a počítače $7 D003201 $2 czmesh
650    _7
$a kardiovaskulární nemoci $x diagnostické zobrazování $x patofyziologie $x prevence a kontrola $7 D002318 $2 czmesh
650    _7
$a banky biologického materiálu $7 D018070 $2 czmesh
650    _7
$a automatizované zpracování dat $x metody $7 D001330 $2 czmesh
650    _7
$a biomedicínský výzkum $7 D035843 $2 czmesh
655    _7
$a práce podpořená grantem $7 D013485 $2 czmesh
655    _7
$a přehledy $7 D016454 $2 czmesh
700    1_
$a Šmondrk, Maroš $7 xx0242516 $u Department of Electromagnetic and Biomedical Engineering, FEIT, University of Zilina
700    1_
$a Janoušek, Ladislav $7 mzk2008448709 $u Department of Electromagnetic and Biomedical Engineering, FEIT, University of Zilina
773    0_
$t Lékař a technika $x 0301-5491 $g Roč. 51, č. 1-4 (2021), s. 53-58 $w MED00011033
910    __
$a ABA008 $b B 1367 $c 1071 b $y p $z 0
990    __
$a 20230517141648 $b ABA008
991    __
$a 20230926121751 $b ABA008
999    __
$a ok $b bmc $g 1935589 $s 1192997
BAS    __
$a 3
BMC    __
$a 2021 $b 51 $c 1-4 $d 53-58 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
LZP    __
$c NLK193 $d 20230926 $a NLK 2023-16/kv

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...