Roboticky asistovaná resekce tumoru ledviny – naše současná nejčastější technika – video
[Robot-assisted resection of renal tumour - our current most common technique - video]

Milan Hora, Ivan Trávníček, Petr Stránský, Adriena Bartoš Veselá, Tomáš Pitra, Hana Sedláčková, Petr Stránský, Dominika Šiková, Kseniia Khomenko, Blanka Drápelová, Jitka Voráčková, Jiří Ferda, Kristýna Pivovarčíková

. 2025 ; 29 (1) : 9-11. [pub] 20250325

Language Czech Country Czech Republic

Aim: To present on video our current most used technique of robot-assisted resection of renal tumour (RR). Material: We performed 274 RRs between June 2020 and November 2024. Our technique is based on a modification of conventional laparoscopic renal resection, of which we performed 599 between August 2004 and May 2020. RRs currently account for over one third of the surgical procedures for kidney cancer at our institution. Laparoscopic (rarely robotic assisted) nephrectomy is almost as frequent. Open resection accounts for about 17% and open nephrectomy for slightly less. Open resections are mainly indicated for more complex tumours, for tumors with significant \"toxic\" fat capsule, and when combined with other procedures, mostly for intestinal malignancies. RR is routinely performed by two console surgeons, occasionally by two additional ones. Operation technique: General anaesthesia. Optional urinary catheter inserted. Lateral position 60-70°. Upper limbs extended in front, close together. Operative field prepared for eventual lumbotomy. Transperitoneal approach. The capnoperitoneum is created with a Veres needle, CO2 pressure 12 mmHg. Assist port 12 mm slightly lateral to the umbilicus. Four 8-mm robotic ports are inserted pararectally under visual control. Four-arm daVinci Xi robotic system is inserted. Ports craniocaudally: 1. ProGrasp, 2. bipolar grasper (bipolar forceps Maryland or more often fenestrated) or monopolar curved scissors (Hot shears) according to the operated side and the dominant hand of the operator, 3. camera 30°, 4. the second of the mentioned instruments from port 2. The scissors are alternated with a needle driver, usually the Large SutureCut needle driver. In the Toldt line, the peritoneum is opened, the colon is retracted medially, and the Gerota fascia is opened medially from the kidney. The necessary part of the kidney is dissected from the fat capsule for good access to the tumour. The tumour is verified sonographically with a drop-in probe inserted through the assistant port. Scissors can be used to mark the line of resection on the kidney. The ureter is verified and the hilar vessels are released. The artery(s) or necessary branch is bypassed with tubing and clamped with the SCANLAN® robotic endo-bulldog. Only in central tumours is the vein also clamped. Knowledge of the topographic anatomy of the vessels from two-phase CT angiography is very helpful at this stage. The effectiveness of ischemia is verified by Doppler; exceptionally (especially in selective clamping of the artery branches) by NIR imaging with FireFly® with administration of indocyanine green - Verdye® 1.25-2.5 mg. The tumour is resected with cold scissors with a rim of healthy tissue. Suturing of the base is performed with an absorbable self-anchoring barbed suture (V-Loc® 90, size 3-0, 1/2 needle 26 mm). The edges of the kidney are mattress sutured with another suture, tightened with Absolok® AP300 absorbable clips (polydioxanone PDS, size ML) - \"sliding clips\" technique. The second layer of the parenchyma is sewn with simple continuation stitches, mostly without continuous anchoring. For more superficial tumours, a straight suture of the parenchyma is

Robot-assisted resection of renal tumour - our current most common technique - video

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc25007702
003      
CZ-PrNML
005      
20250606111134.0
007      
ta
008      
250411s2025 xr ad f 000 0|cze||
009      
AR
024    7_
$a 10.48095/cccu2025004 $2 doi
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Hora, Milan, $d 1967- $7 mzk2004258359 $u Urologická klinika LF UK a FN Plzeň
245    10
$a Roboticky asistovaná resekce tumoru ledviny – naše současná nejčastější technika – video / $c Milan Hora, Ivan Trávníček, Petr Stránský, Adriena Bartoš Veselá, Tomáš Pitra, Hana Sedláčková, Petr Stránský, Dominika Šiková, Kseniia Khomenko, Blanka Drápelová, Jitka Voráčková, Jiří Ferda, Kristýna Pivovarčíková
246    31
$a Robot-assisted resection of renal tumour - our current most common technique - video
520    9_
$a Aim: To present on video our current most used technique of robot-assisted resection of renal tumour (RR). Material: We performed 274 RRs between June 2020 and November 2024. Our technique is based on a modification of conventional laparoscopic renal resection, of which we performed 599 between August 2004 and May 2020. RRs currently account for over one third of the surgical procedures for kidney cancer at our institution. Laparoscopic (rarely robotic assisted) nephrectomy is almost as frequent. Open resection accounts for about 17% and open nephrectomy for slightly less. Open resections are mainly indicated for more complex tumours, for tumors with significant \"toxic\" fat capsule, and when combined with other procedures, mostly for intestinal malignancies. RR is routinely performed by two console surgeons, occasionally by two additional ones. Operation technique: General anaesthesia. Optional urinary catheter inserted. Lateral position 60-70°. Upper limbs extended in front, close together. Operative field prepared for eventual lumbotomy. Transperitoneal approach. The capnoperitoneum is created with a Veres needle, CO2 pressure 12 mmHg. Assist port 12 mm slightly lateral to the umbilicus. Four 8-mm robotic ports are inserted pararectally under visual control. Four-arm daVinci Xi robotic system is inserted. Ports craniocaudally: 1. ProGrasp, 2. bipolar grasper (bipolar forceps Maryland or more often fenestrated) or monopolar curved scissors (Hot shears) according to the operated side and the dominant hand of the operator, 3. camera 30°, 4. the second of the mentioned instruments from port 2. The scissors are alternated with a needle driver, usually the Large SutureCut needle driver. In the Toldt line, the peritoneum is opened, the colon is retracted medially, and the Gerota fascia is opened medially from the kidney. The necessary part of the kidney is dissected from the fat capsule for good access to the tumour. The tumour is verified sonographically with a drop-in probe inserted through the assistant port. Scissors can be used to mark the line of resection on the kidney. The ureter is verified and the hilar vessels are released. The artery(s) or necessary branch is bypassed with tubing and clamped with the SCANLAN® robotic endo-bulldog. Only in central tumours is the vein also clamped. Knowledge of the topographic anatomy of the vessels from two-phase CT angiography is very helpful at this stage. The effectiveness of ischemia is verified by Doppler; exceptionally (especially in selective clamping of the artery branches) by NIR imaging with FireFly® with administration of indocyanine green - Verdye® 1.25-2.5 mg. The tumour is resected with cold scissors with a rim of healthy tissue. Suturing of the base is performed with an absorbable self-anchoring barbed suture (V-Loc® 90, size 3-0, 1/2 needle 26 mm). The edges of the kidney are mattress sutured with another suture, tightened with Absolok® AP300 absorbable clips (polydioxanone PDS, size ML) - \"sliding clips\" technique. The second layer of the parenchyma is sewn with simple continuation stitches, mostly without continuous anchoring. For more superficial tumours, a straight suture of the parenchyma is
650    17
$a nádory ledvin $x chirurgie $7 D007680 $2 czmesh
650    07
$a roboticky asistované výkony $x metody $7 D065287 $2 czmesh
650    07
$a nefrektomie $7 D009392 $2 czmesh
650    07
$a laparoskopie $7 D010535 $2 czmesh
650    07
$a lidé $7 D006801 $2 czmesh
700    1_
$a Trávníček, Ivan $7 xx0227802 $u Urologická klinika LF UK a FN Plzeň
700    1_
$a Stránský, Petr $u Urologická klinika LF UK a FN Plzeň $7 xx0068051
700    1_
$a Bartoš Veselá, Adriena $u Urologická klinika LF UK a FN Plzeň $7 xx0255445
700    1_
$a Pitra, Tomáš $u Urologická klinika LF UK a FN Plzeň $7 xx0227763
700    1_
$a Sedláčková, Hana $u Urologická klinika LF UK a FN Plzeň $7 xx0233004
700    1_
$a Stránský, Petr $u Urologická klinika LF UK a FN Plzeň $7 xx0068051
700    1_
$a Šiková, Dominika $u Urologická klinika LF UK a FN Plzeň $7 xx0323804
700    1_
$a Khomenko, Kseniia $u Urologická klinika LF UK a FN Plzeň $7 xx0318840
700    1_
$a Drápelová, Blanka $u Urologická klinika LF UK a FN Plzeň $7 xx0209393
700    1_
$a Voráčková, Jitka $u Urologická klinika LF UK a FN Plzeň $7 _AN122349
700    1_
$a Ferda, Jiří, $u Klinika zobrazovacích metod LF UK a FN Plzeň $d 1970- $7 nlk20040148200
700    1_
$a Pivovarčíková, Kristýna $u Šiklův ústav patologie LF UK a FN Plzeň $7 xx0233028
773    0_
$t Česká urologie $x 1211-8729 $g Roč. 29, č. 1 (2025), s. 9-11 $w MED00011150
856    41
$u https://czechurol.cz/en/artkey/cur-202501-0002_roboticky_asistovana_resekce_tumoru_ledviny_8211_nase_soucasna_nejcastejsi_technika_8211_video.php $y plný text volně přístupný
910    __
$a ABA008 $b B 2095 $c 916 $y p $z 0
990    __
$a 20250401 $b ABA008
991    __
$a 20250606111126 $b ABA008
999    __
$a ok $b bmc $g 2308006 $s 1244777
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2025 $b 29 $c 1 $d 9-11 $e 20250325 $i 1211-8729 $m Česká urologie $x MED00011150
LZP    __
$c NLK183 $d 20250515 $b NLK111 $a Actavia-MED00011150-20250401

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...