Characteristics of sentinel lymph nodes' metastatic involvement in early stage of vulvar cancer
Language English Country Australia Media print
Document type Controlled Clinical Trial, Journal Article
PubMed
20070721
DOI
10.1111/j.1479-828x.2009.01073.x
PII: AJO1073
Knihovny.cz E-resources
- MeSH
- Sentinel Lymph Node Biopsy * MeSH
- Adult MeSH
- Cohort Studies MeSH
- Middle Aged MeSH
- Humans MeSH
- Lymphatic Metastasis MeSH
- Vulvar Neoplasms diagnostic imaging pathology surgery MeSH
- Predictive Value of Tests MeSH
- Radionuclide Imaging MeSH
- Reproducibility of Results MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Carcinoma, Squamous Cell diagnostic imaging secondary surgery MeSH
- Neoplasm Staging MeSH
- Groin MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Controlled Clinical Trial MeSH
BACKGROUND: Nodal involvement is one of the most significant prognostic factors in early-stage vulvar cancer. AIMS: To determine the diagnostic accuracy of sentinel lymph node (SLN) detection in early-stage vulvar cancer and to describe the characteristics of metastatic lymph node involvement. METHODS: Of 23 women with early-stage squamous cell vulvar cancer included in the study, five had lateral lesions and 18 had midline lesions. SLN detection was performed by using a radioactive tracer and blue dye, followed by radical vulvectomy or radical wide excision with uni/bilateral inguinofemoral lymphadenectomy, depending on tumour size and localization. SLNs were subsequently examined with haematoxylin-eosin and immunohistochemistry. RESULTS: The SLN detection was successful in all 23 women (100%) and in 38 of 41 groins (92.3%) tested. The total number of SLNs was 67, with an average of 1.76 per groin. In total, 20 positive SLNs were detected in 14 of 23 patients. From a total of 20 positive SLNs, micrometastases were found in five SLNs and isolated tumour cells in one SLN. We experienced one case with a false negativity of SLN. Sensitivity, negative predictive value, accuracy and false negativity of SLN detection were 93.3%, 88.8%, 95.6% and 7.1% respectively. CONCLUSION: The SLN biopsy performed by an experienced team is a feasible method, with high accuracy in patients with early-stage vulvar cancer. Prognostic value of micrometastases should be confirmed in further studies.
References provided by Crossref.org
Detection of Sentinel Lymph Nodes in Gynecologic Tumours by Planar Scintigraphy and SPECT/CT