Robotic navigation in catheter ablation for paroxysmal atrial fibrillation: midterm efficacy and predictors of postablation arrhythmia recurrences
Jazyk angličtina Země Spojené státy americké Médium print-electronic
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- chirurgie s pomocí počítače MeSH
- fibrilace síní epidemiologie chirurgie MeSH
- hodnocení rizik MeSH
- katetrizační ablace statistika a číselné údaje MeSH
- komorbidita MeSH
- lidé středního věku MeSH
- lidé MeSH
- pooperační komplikace epidemiologie prevence a kontrola MeSH
- prognóza MeSH
- recidiva MeSH
- rizikové faktory MeSH
- robotika statistika a číselné údaje MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Česká republika epidemiologie MeSH
INTRODUCTION: Remote navigation systems represent a novel strategy for catheter ablation of atrial fibrillation (AF). The goal of this study is to describe a single-center experience with the electromechanical robotic system (Sensei, Hansen Medical) in treatment of patients with paroxysmal AF. METHODS: Out of 200 patients who underwent robotically guided ablation for AF between 2007 and 2009 at our institute, 100 patients (29 women, age 56.5 ± 10 years) had paroxysmal AF refractory to antiarrhythmic drugs. Electroanatomic mapping using NavX system (St. Jude Medical) provided anatomical shell for subsequent circumferential ablation with robotic catheter (Artisan) loaded with a 3.5-mm, open-irrigation, cooled-tip ablation catheter. RESULTS: A mean of 69 radiofrequency current applications (duration 2082 ± 812 seconds) were delivered to achieve circumferential electrical isolation of pulmonary venous antra. Total procedural time reached 222 ± 54 minutes. The mean fluoroscopic time was 11.9 ± 7.8 minutes. There were no major procedure-related complications. After a median follow-up of 15 months (range 3-28 months), 63% of the patients were free from any atrial arrhythmias ≥ 30 seconds after the single procedure. Success rate increased to 86% after 1.2 procedures. Multivariate analysis revealed that only predictor of recurrent AF/AT was shorter overall procedural time (207 ± 36 vs 236 ± 64 minutes in patients with and without recurrences, respectively, P = 0.0068). CONCLUSIONS: This study demonstrates feasibility and safety of robotic navigation in catheter ablation for paroxysmal AF. Midterm follow-up documents success rate comparable to other technologies and potential for improvement in more extensive ablation along the ridges with thicker myocardium.
Citace poskytuje Crossref.org
Reduction of Fluoroscopy Time and Radiation Dosage During Catheter Ablation for Atrial Fibrillation
Contact Force Assessment In Catheter Ablation Of Atrial Fibrillation