Wavelet transform analysis to assess oscillations in pial artery pulsation at the human cardiac frequency
Jazyk angličtina Země Spojené státy americké Médium print-electronic
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
25804326
DOI
10.1016/j.mvr.2015.03.003
PII: S0026-2862(15)00030-8
Knihovny.cz E-zdroje
- Klíčová slova
- Cardiac frequency, Cerebral blood flow, NIR-T/BSS, Pial artery, Wavelet transform analysis,
- MeSH
- apnoe patologie MeSH
- arteria carotis interna patologie MeSH
- arterie patologie MeSH
- dospělí MeSH
- elektrokardiografie MeSH
- krevní tlak MeSH
- lidé MeSH
- mladý dospělý MeSH
- mozkový krevní oběh MeSH
- oscilometrie metody MeSH
- pia mater krevní zásobení MeSH
- rychlost toku krve fyziologie MeSH
- srdeční frekvence MeSH
- transiluminace metody MeSH
- ultrasonografie dopplerovská transkraniální MeSH
- vlnková analýza * MeSH
- zadržování dechu MeSH
- zdraví dobrovolníci pro lékařské studie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Pial artery adjustments to changes in blood pressure (BP) may last only seconds in humans. Using a novel method called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) in humans, we aimed to assess the relationship between spontaneous oscillations in BP and cc-TQ at frequencies between 0.5 Hz and 5 Hz. We hypothesized that analysis of very short data segments would enable the estimation of changes in the cardiac contribution to the BP vs. cc-TQ relationship during very rapid pial artery adjustments to external stimuli. BP and pial artery oscillations during baseline (70s and 10s signals) and the response to maximal breath-hold apnea were studied in eighteen healthy subjects. The cc-TQ was measured using NIR-T/BSS; cerebral blood flow velocity, the pulsatility index and the resistive index were measured using Doppler ultrasound of the left internal carotid artery; heart rate and beat-to-beat systolic and diastolic blood pressure were recorded using a Finometer; end-tidal CO2 was measured using a medical gas analyzer. Wavelet transform analysis was used to assess the relationship between BP and cc-TQ oscillations. The recordings lasting 10s and representing 10 cycles with a frequency of ~1 Hz provided sufficient accuracy with respect to wavelet coherence and wavelet phase coherence values and yielded similar results to those obtained from approximately 70cycles (70s). A slight but significant decrease in wavelet coherence between augmented BP and cc-TQ oscillations was observed by the end of apnea. Wavelet transform analysis can be used to assess the relationship between BP and cc-TQ oscillations at cardiac frequency using signals intervals as short as 10s. Apnea slightly decreases the contribution of cardiac activity to BP and cc-TQ oscillations.
Department of Hypertension and Diabetology Medical University of Gdansk Gdansk Poland
Department of Radiology Informatics and Statistics Medical University of Gdansk Gdansk Poland
Institute of Human Physiology Medical University of Gdansk Gdansk Poland
Citace poskytuje Crossref.org