Detection and Quantification of Carbohydrate-Deficient Transferrin by MALDI-Compatible Protein Chips Prepared by Ambient Ion Soft Landing
Language English Country Great Britain, England Media print-electronic
Document type Journal Article, Research Support, Non-U.S. Gov't
PubMed
30002097
DOI
10.1373/clinchem.2017.285452
PII: clinchem.2017.285452
Knihovny.cz E-resources
- MeSH
- Biomarkers blood MeSH
- Humans MeSH
- Reference Standards MeSH
- Reproducibility of Results MeSH
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization instrumentation MeSH
- Case-Control Studies MeSH
- Transferrin analogs & derivatives metabolism standards MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Names of Substances
- Biomarkers MeSH
- carbohydrate-deficient transferrin MeSH Browser
- Transferrin MeSH
BACKGROUND: Transferrin is synthetized in the liver and is the most important iron-transport carrier in the human body. Severe alcohol consumption leads to alterations in glycosylation of transferrin. Mass spectrometry can provide fast detection and quantification of transferrin isoforms because they have different molecular masses. In this study, we used antibody chips in combination with MALDI-TOF MS for the detection and quantification of transferrin isoforms. METHODS: Protein chips were prepared by functionalization of indium tin oxide glass using ambient ion soft landing of electrosprayed antitransferrin antibody. Two microliters of patient serum was applied on the antibody-modified spots, and after incubation, washing, and matrix deposition, transferrin isoforms were detected by MALDI-TOF MS. Peak intensities of each transferrin form were used to calculate total carbohydrate-deficient transferrin (CDT). The CDT values obtained by the MALDI chip method were compared with the results obtained by a standard capillary electrophoresis (CE). RESULTS: The chip-based MALDI-TOF MS method was used for enrichment and detection of CDT from human serum. A sample cohort from 186 patients was analyzed. Of these samples, 44 were positively identified as belonging to alcoholic patients, whereas 142 were negative by the MALDI chip approach. The correlation of the data obtained by the CE and the chip-based MALDI was r = 0.986, 95% CI. CONCLUSIONS: Functionalized MALDI chips modified by antitransferrin antibody prepared by ambient ion soft landing were successfully used for detection and quantification of CDT from human sera.
AffiPro s r o Mratin Czech Republic
BioVendor Karasek Brno Czech Republic
Department of Immunochemistry University Hospital in Pilsen Pilsen Czech Republic
Department of Laboratory Diagnostics University Hospital Kralovske Vinohrady Prague Czech Republic
Faculty of Science Charles University Prague Czech Republic
Institute of Microbiology v v i Czech Academy of Sciences Prague Czech Republic
Institute of Microbiology v v i Czech Academy of Sciences Prague Czech Republic;
References provided by Crossref.org
The rapid detection of procalcitonin in septic serum using immunoaffinity MALDI chips