Quality by Design as a risk-based strategy in pharmaceutical analysis: Development of a liquid chromatography-tandem mass spectrometry method for the determination of nintedanib and its impurities
Language English Country Netherlands Media print-electronic
Document type Journal Article
PubMed
31630831
DOI
10.1016/j.chroma.2019.460615
PII: S0021-9673(19)31022-2
Knihovny.cz E-resources
- Keywords
- Experimental design, Impurities, LC-MS/MS, Method operable design region, Nintedanib, Quality by Design,
- MeSH
- Chromatography, Liquid methods MeSH
- Indoles analysis chemistry MeSH
- Monte Carlo Method MeSH
- Probability MeSH
- Reproducibility of Results MeSH
- Quality Control MeSH
- Risk MeSH
- Solvents MeSH
- Tandem Mass Spectrometry methods MeSH
- Publication type
- Journal Article MeSH
- Names of Substances
- Indoles MeSH
- nintedanib MeSH Browser
- Solvents MeSH
Nintedanib (NIN) is a tyrosine kinase inhibitor recently approved for the treatment of idiopathic pulmonary fibrosis. As a new drug, no monograph is available so far in official compendia. A liquid chromatography-tandem mass spectrometry method is presented for the simultaneous determination of NIN and its seven potential impurities. The risk-based approach of Analytical Quality by Design was applied in method development. The critical method parameters (CMPs) were the type of organic solvent in the mobile phase, formic acid percentage, column flow rate, oven temperature, gradient slope of organic eluent. The critical method attributes (CMAs) were selected as analysis time and selectivity between the main compound NIN and the adjacent peaks. Design of Experiments methodology was effectively employed for establishing the relationship between the CMPs and the CMAs. In the scouting step, a Restek Ultra AQ C18 (100 × 2.1 mm, 2.7 µm) core-shell column was selected, and then the effects of different levels of the five CMPs on the CMAs were evaluated by means of a 35//16 symmetric screening matrix. A Box-Behnken Design made it possible to obtain detailed maps of predicted CMAs throughout the investigated experimental domain, pointing out the presence of interaction and quadratic effects. The probability of meeting the specifications for the CMAs was calculated by Monte-Carlo simulations, performing a risk analysis and drawing risk of failure maps, which were used to visualize and define the method operable design region (MODR) with a probability π ≥ 90%. The final working conditions (enclosing the MODR interval) were as follows: methanol as organic solvent; formic acid percentage, 0.15% v/v; flow rate, 0.40 mL min-1 (0.37-0.43 mL min-1); oven temperature, 40 °C (38-40 °C); gradient slope of organic eluent, 14.00% eluent B min-1 (12.85-15.15% eluent B min-1). The resulting analysis time was about 10 min. Validation was carried out according to International Council for Harmonisation guidelines and the optimized method was applied to the analysis of NIN soft capsules for quality control purposes.
Department of Pharmacy and Biotechnology University of Bologna Via Belmeloro 6 40126 Bologna Italy
Mass Spectrometry Center University of Florence Viale G Pieraccini 6 50139 Florence Italy
Zentiva k s Praha U Kabelovny 130 102 37 Praha 10 Czech Republic
References provided by Crossref.org