INTRODUCTION: Surgical experience and hospital procedure volumes have been associated with the risk of severe complications in expert centers for endometriosis in France. However, little is known about other certified units in Central European countries. MATERIAL AND METHODS: This retrospective observational study included 937 women who underwent surgery for colorectal endometriosis between January 2018 and January 2020 in 19 participating expert centers for endometriosis. All women underwent complete excision of colorectal endometriosis by rectal shaving, discoid or segmental resection. Postoperative severe complications were defined as grades III-IV of the Clavien-Dindo classification system including anastomotic leakage, fistula, pelvic abscess and hematoma. Surgical outcomes of centers performing less than 40 (group 1), 40-59 (group 2) and ≥60 procedures (group 3) over a period of 2 years were compared. RESULTS: The overall complication rate of grade III and IV complications was 5.1% (48/937), with rates of anastomotic leakage, fistula formation, abscess and hemorrhage in segmental resection, discoid resection and rectal shaving, respectively, as follows: anastomotic leakage 3.6% (14/387), 1.4% (3/222), 0.6% (2/328); fistula formation 1.6% (6/387), 0.5% (1/222), 0.9%; (3/328); abscess 0.5% (2/387), 0% (0/222) and 0.6% (2/328); hemorrhage 2.1% (8/387), 0.9% (2/222) and 1.5% (5/328). Higher overall complication rates were observed for segmental resection (30/387, 7.8%) than for discoid (6/222, 2.7%, P = 0.015) or shaving procedures (12/328, 3.7%, P = 0.089). No significant correlation was observed between the number of procedures performed and overall complication rates (rSpearman = -0.115; P = 0.639) with a high variability of complications in low-volume centers (group 1). However, an intergroup comparison revealed a significantly lower overall severe complication rate in group 3 than in group 2 (2.9% vs 6.9%; P = 0.017) without significant differences between other groups. CONCLUSIONS: A high variability in complication rates does exist in centers with a low volume of activity. Major complications may decrease with an increase in the volume of activity but this effect cannot be generally applied to all institutions and settings.
- MeSH
- absces komplikace etiologie MeSH
- endometrióza * komplikace chirurgie MeSH
- kolorektální chirurgie * škodlivé účinky MeSH
- kolorektální nádory * komplikace chirurgie MeSH
- laparoskopie * metody MeSH
- lidé MeSH
- nemoci rekta * chirurgie MeSH
- netěsnost anastomózy epidemiologie etiologie chirurgie MeSH
- pooperační komplikace etiologie MeSH
- retrospektivní studie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
A European round robin test according to ISO 5725-2 was conceptually prepared, realised, and evaluated. The aim was to determine the inter-laboratory variability of the overall process for the ecotoxicological characterization of construction products in eluates and bioassays. To this end, two construction products BAM-G1 (granulate) and HSR-2 (roof sealing sheet), both made of EPDM polymers (rubber), were selected. The granular construction product was eluted in a one stage batch test, the planar product in the Dynamic Surface Leaching test (DSLT). A total of 17 laboratories from 5 countries participated in the round robin test: Germany (12), Austria (2), Belgium (1), Czech Republic (1) and France (1). A test battery of four standardised ecotoxicity tests with algae, daphnia, luminescent bacteria and zebrafish eggs was used. As toxicity measures, EC50 and LID values were calculated. All tests, except the fish egg test, were basically able to demonstrate toxic effects and the level of toxicity. The reproducibility of test results depended on the test specimens and the test organisms. Generally, the variability of the EC50 or LID values increased with the overall level of toxicity. For the very toxic BAM-G1 eluate a relative high variability of CV = 73%-110% was observed for EC50 in all biotests, while for the less toxic HSR-2 eluate the reproducibility of EC50 varied with sensitivity: it was very good (CV = 9.3%) for the daphnia test with the lowest sensitivity, followed by the algae test (CV = 36.4%). The luminescent bacteria test, being the most sensitive bioassay for HSR-2 Eluate, showed the highest variability (CV = 74.8%). When considering the complex overall process the reproducibility of bioassays with eluates from construction products was acceptable.
- MeSH
- Bacteria účinky léků MeSH
- biotest metody normy MeSH
- chemické látky znečišťující vodu analýza toxicita MeSH
- dánio pruhované MeSH
- Daphnia účinky léků MeSH
- ekotoxikologie metody normy MeSH
- elastomery toxicita MeSH
- ethyleny toxicita MeSH
- guma toxicita MeSH
- Heterokontophyta účinky léků MeSH
- odchylka pozorovatele MeSH
- reprodukovatelnost výsledků MeSH
- testy toxicity metody normy MeSH
- vejce MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH