The treatment of cartilage defects in trauma injuries and degenerative diseases represents a challenge for orthopedists. Advanced mesenchymal stromal cell (MSC)-based therapies are currently of interest for the repair of damaged cartilage. However, an approved system for MSC delivery and maintenance in the defect is still missing. This study aimed to evaluate the effect of autologous porcine bone marrow MSCs anchored in a commercially available polyglycolic acid-hyaluronan scaffold (Chondrotissue®) using autologous blood plasma-based hydrogel in the repair of osteochondral defects in a large animal model. The osteochondral defects were induced in twenty-four minipigs with terminated skeletal growth. Eight animals were left untreated, eight were treated with Chondrotissue® and eight received Chondrotissue® loaded with MSCs. The animals were terminated 90 days after surgery. Macroscopically, the untreated defects were filled with newly formed tissue to a greater extent than in the other groups. The histological evaluations showed that the defects treated with Chondrotissue® and Chondrotissue® loaded with pBMSCs contained a higher amount of hyaline cartilage and a lower amount of connective tissue, while untreated defects contained a higher amount of connective tissue and a lower amount of hyaline cartilage. In addition, undifferentiated connective tissue was observed at the edges of defects receiving Chondrotissue® loaded with MSCs, which may indicate the extracellular matrix production by transplanted MSCs. The immunological analysis of the blood samples revealed no immune response activation by MSCs application. This study demonstrated the successful and safe immobilization of MSCs in commercially available scaffolds and defect sites for cartilage defect repair.
- MeSH
- hydrogely MeSH
- kloubní chrupavka * chirurgie MeSH
- krevní plazma MeSH
- mezenchymální kmenové buňky * fyziologie MeSH
- miniaturní prasata MeSH
- modely u zvířat MeSH
- prasata MeSH
- tkáňové inženýrství MeSH
- transplantace mezenchymálních kmenových buněk * MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE OF THE STUDY Fixation of osteochondral fragments are relatively common procedures in pediatric orthopaedic surgery. The use of biodegradable magnesium implants in these indications appears to be a promising alternative to polymer implants due to their favorable mechanical properties and biological behavior. The purpose of this study is to evaluate the short-term clinical and radiological outcomes of the fixation of unstable or displaced osteochondral fractures and osteochondritis dissecans lesions in the knee joint using MAGNEZIX® screws and pins in pediatric patients. MATERIAL AND METHODS In this study, 12 patients (5 girls, 7 boys) were included. The inclusion criteria were as follows (1) age below 18 years; (2) unstable or displaced osteochondral fragments secondary to trauma or as a result of osteochondritis dissecans, Grades III and IV in the ICRS (International Cartilage Repair Society) score, confirmed by imaging methods and indicated for surgical fixation; (3) fixation performed using screws or pins made of the magnesium-based MAGNEZIX® alloy; (4) minimum postoperative interval of 12 months. X-rays and clinical evaluation were assessed 1 day, 6 weeks, 3, 6, and 12 months after the operation. MRIs were performed 1-year postoperatively for evaluation of bone response and degradation behavior of implants. RESULTS The mean age at surgery was 13.3 ± 1.6 years. A total of 25 screws were used in 11 patients, a mean of 2.4 ± 1 per patient, 4 pins were used in 1 patient. In 2 patients, fixation with screws was complemented with fibrin glue. The mean follow-up was 14.2 ± 3.3 months. All patients exhibited complete functional recovery while showing no signs of pain at 6 months postoperatively. No adverse local reactions were observed. At 1-year follow-up, no implant failure has been reported. Complete radiographic healing occurred in 12 cases. Mild radiolucent zones were observed around the implants. CONCLUSIONS The use of screws and pins MAGNEZIX® has been found to provide satisfactory outcomes in terms of fracture healing and very good functional outcomes at 1 year postoperatively. Key words: biodegradable implants, magnesium-based implants, osteochondral fracture, osteochondritis dissecans, MAGNEZIX®.
- MeSH
- dítě MeSH
- fraktury kostí * MeSH
- hojení fraktur MeSH
- hořčík MeSH
- kolenní kloub diagnostické zobrazování chirurgie MeSH
- kostní hřeby MeSH
- lidé MeSH
- mladiství MeSH
- následné studie MeSH
- osteochondritis dissecans * diagnostické zobrazování chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- dítě MeSH
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: The appropriate treatment of pulseless pink supracondylar humerus fractures (SCHF) remains controversial. In this study, the outcomes of two treatment approaches (with and without vascular surgery) were compared. MATERIAL AND METHODS: This was a retrospective multicenter study of patients with pulseless pink SCHFs treated in ten pediatric surgery, trauma, or orthopedics departments in the Czech and Slovak Republic between 2014 and 2018. RESULTS: Of the total 3608 cases of displaced SCHF, 125 had the pulseless pink SCHF. Of those, 91% (114/125) did not undergo vascular surgery and 9% (11/125) underwent vascular surgery. The patients who did undergo vascular surgery had radial artery pulsation restored more frequently in the operating room (73% vs. 36%; p = 0.02), within 6 h (91% vs. 45%; p = 0.004), and within 24 h of surgery (91% vs. 57%; p = 0.05). However, 72 h after surgery, there was no significant difference in palpable radial artery pulsation between the vascular surgery and the non-vascular surgery groups (91% vs. 74%; p = 0.24). Additionally, no significant differences in long-term neurological (9% vs. 22%; p = 0.46) or circulatory (9% vs. 7%; p = 0.57) deficits were found between the two groups. CONCLUSION: While vascular surgery in patients with pulseless pink SCHFs is associated with a more prompt restoration of radial artery pulsation, no statistical significant differences in terms of the restoration of neurological deficits or the risks of long-term neurological or circulatory deficits were found between patients with and without vascular surgery.
x
x