OBJECTIVE: Radiographic assessment of sacroiliac joints (SIJs) according to the modified New York (mNY) criteria is key in the classification of axial spondyloarthritis but has moderate interreader agreement. We aimed to investigate the improvements of the reliability in scoring SIJ radiographs after applying an online real-time iterative calibration (RETIC) module, in addition to a slideshow and video alone. METHODS: Nineteen readers, randomized to 2 groups (A or B), completed 3 calibration steps: (1) review of manuscripts, (2) review of slideshow and video with group A completing RETIC, and (3) re-review of slideshow and video with group B completing RETIC. The RETIC module gave instant feedback on readers' gradings and continued until predefined reliability ([Formula: see text]) targets for mNY positivity/negativity were met. Each step was followed by scoring different batches of 25 radiographs (exercises I to III). Agreement ([Formula: see text]) with an expert radiologist was assessed for mNY positivity/negativity and individual lesions. Improvements by training strategies were tested by linear mixed models. RESULTS: In exercises I, II, and III, mNY [Formula: see text] were 0.61, 0.76, and 0.84, respectively, in group A; and 0.70, 0.68, and 0.86, respectively, in group B (ie, increasing, mainly after RETIC completion). Improvements were observed for grading both mNY positivity/negativity and individual pathologies, both in experienced and, particularly, inexperienced readers. Completion of the RETIC module in addition to the slideshow and video caused a significant [Formula: see text] increase of 0.17 (95% CI 0.07-0.27; P = 0.002) for mNY-positive and mNY-negative grading, whereas completion of the slideshow and video alone did not ([Formula: see text] = 0.00, 95% CI -0.10 to 0.10; P = 0.99). CONCLUSION: Agreement on scoring radiographs according to the mNY criteria significantly improved when adding an online RETIC module, but not by slideshow and video alone.
- MeSH
- axiální spondyloartritida * diagnostické zobrazování MeSH
- lidé MeSH
- odchylka pozorovatele * MeSH
- rentgendiagnostika * metody MeSH
- reprodukovatelnost výsledků MeSH
- sakroiliakální kloub * diagnostické zobrazování MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
BACKGROUND: The Spondyloarthritis Research Consortium of Canada (SPARCC) developers have created web-based calibration modules for the SPARCC MRI sacroiliac joint (SIJ) scoring methods. We aimed to test the impact of applying these e-modules on the feasibility and reliability of these methods. METHODS: The SPARCC-SIJ RETIC e-modules contain cases with baseline and follow-up scans and an online scoring interface. Visual real-time feedback regarding concordance/discordance of scoring with expert readers is provided by a colour-coding scheme. Reliability is assessed in real time by intraclass correlation coefficient (ICC), cases being scored until ICC targets are attained. Participating readers (n=17) from the EuroSpA Imaging project were randomised to one of two reader calibration strategies that each comprised three stages. Baseline and follow-up scans from 25 cases were scored after each stage was completed. Reliability was compared with a SPARCC developer, and the System Usability Scale (SUS) assessed feasibility. RESULTS: The reliability of readers for scoring bone marrow oedema was high after the first stage of calibration, and only minor improvement was noted following the use of the inflammation module. Greater enhancement of reader reliability was evident after the use of the structural module and was most consistently evident for the scoring of erosion (ICC status/change: stage 1 (0.42/0.20) to stage 3 (0.50/0.38)) and backfill (ICC status/change: stage 1 (0.51/0.19) to stage 3 (0.69/0.41)). The feasibility of both e-modules was evident by high SUS scores. CONCLUSION: The SPARCC-SIJ RETIC e-modules are feasible, effective knowledge transfer tools, and their use is recommended before using the SPARCC methods for clinical research and tria.
- MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody MeSH
- reprodukovatelnost výsledků MeSH
- sakroiliakální kloub * diagnostické zobrazování patologie MeSH
- spondylartritida * diagnóza patologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
- Geografické názvy
- Kanada MeSH