"MZCZ-DRO-VFN64165"
Dotaz
Zobrazit nápovědu
PURPOSE: The objective of our study was to evaluate the diagnostic accuracy of internal jugular vein (IJV) collapsibility as a predictor of fluid responsiveness in spontaneously breathing patients after cardiac surgery. METHODS: In this prospective observational study, spontaneously breathing patients were enrolled on the first postoperative day after coronary artery bypass grafting. Hemodynamic data coupled with simultaneous ultrasound assessment of the IJV were collected at baseline and after passive leg raising test (PLR). Continuous cardiac index (CI), stroke volume (SV), and stroke volume variation (SVV) were assessed with FloTracTM/EV1000TM. Fluid responsiveness was defined as an increase in CI ≥ 10% after PLR. We compared the differences in measured variables between fluid responders and non-responders and tested the ability of ultrasonographic IJV indices to predict fluid responsiveness. RESULTS: Fifty-four patients were included in the study. Seventeen (31.5%) were fluid responders. The responders demonstrated significantly lower inspiratory and expiratory diameters of the IJV at baseline, but IJV collapsibility was comparable (P = 0.7). Using the cut-off point of 20%, IJV collapsibility predicted fluid responsiveness with a sensitivity of 76.5% and specificity of 38.9%, ROC AUC 0.55. CONCLUSION: In spontaneously breathing patients after surgical coronary revascularisation, collapsibility of the internal jugular vein did not predict fluid responsiveness.
- MeSH
- dýchání MeSH
- hemodynamika MeSH
- kardiochirurgické výkony * MeSH
- lidé MeSH
- tekutinová terapie MeSH
- tepový objem MeSH
- venae jugulares * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
In patients with acute circulatory failure, fluid administration represents a first-line therapeutic intervention for improving cardiac output. However, only approximately 50% of patients respond to fluid infusion with a significant increase in cardiac output, defined as fluid responsiveness. Additionally, excessive volume expansion and associated hyperhydration have been shown to increase morbidity and mortality in critically ill patients. Thus, except for cases of obvious hypovolaemia, fluid responsiveness should be routinely tested prior to fluid administration. Static markers of cardiac preload, such as central venous pressure or pulmonary artery wedge pressure, have been shown to be poor predictors of fluid responsiveness despite their widespread use to guide fluid therapy. Dynamic tests including parameters of aortic blood flow or respiratory variability of inferior vena cava diameter provide much higher diagnostic accuracy. Nevertheless, they are also burdened with several significant limitations, reducing the reliability, or even precluding their use in many clinical scenarios. This non-systematic narrative review aims to provide an update on the novel, less employed dynamic tests of fluid responsiveness evaluation in critically ill patients.
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
Fabry disease (FD) is a rare X-linked disorder of glycosphingolipid metabolism caused by pathogenic variants within the alpha-galactosidase A (GLA) gene, often leading to neurological manifestations including stroke. Multiple screening programs seeking GLA variants among stroke survivors lacked detailed phenotype description, making the interpretation of the detected variant's pathogenicity difficult. Here, we describe detailed clinical characteristics of GLA variant carriers identified by a nationwide stroke screening program in the Czech Republic. A total of 23 individuals with 8 different GLA variants were included in the study. A comprehensive diagnostic workup was performed by a team of FD specialists. The investigation led to the suggestion of phenotype reclassification for the G325S mutation from late-onset to classical. A novel variant R30K was found and was classified as a variant of unknown significance (VUS). The typical manifestation in our FD patients was a stroke occurring in the posterior circulation with an accompanying pathological finding in the cerebrospinal fluid. Moreover, we confirmed that cornea verticillata is typically associated with classical variants. Our findings underline the importance of detailed phenotype description and data sharing in the correct identification of pathogenicity of gene variants detected by high-risk-population screening programs.
- Publikační typ
- časopisecké články MeSH
Videolaryngoscopes may improve intubating conditions in obese patients. A total of 110 patients with a body mass index > 35 kg∙m-2 were prospectively randomized to tracheal intubation using non-channeled Glidescope Titanium or channeled King Vision videolaryngoscope. The primary outcome was the time to tracheal intubation. Secondary outcomes included: total success rate, number of attempts, the quality of visualization, peri-procedural and post-proceduralcomplications. Time to the first effective breath was shorter with the King Vision (median; 95% CI)-36; 34-39 s vs. 42; 40-50 in the Glidescope group (p = 0.007). The total success rate was higher in the Glidescope group-100% vs. 89.1% (p = 0.03). There was a higher incidence of moderate and difficult laryngoscopy in the King Vision group. No difference was recorded in first attempt success rates, total number of attempts, use of additional maneuvers, intraoperative trauma, or any significant decrease in SpO2 during intubation. No serious complications were noted and the incidence of postoperative complaints was without difference. Although tracheal intubation with King Vision showed shorter time to the first breath, total success was higher in the Glidescope group, and all but one patients where intubation failed with the KingVision were subsequently intubated with the Glidescope.
- Publikační typ
- časopisecké články MeSH
BACKGROUND: The aim of this study was to compare plasma levobupivacaine concentrations in thoracic epidural and subpleural paravertebral analgesia. METHODS: Forty-four patients indicated for open lung resection had an epidural catheter inserted preoperatively or a subpleural catheter surgically. A bolus of 0.25% levobupivacaine at a dosage of 0.5 mg × kg-1 was given after the thoracotomy closure. Plasma levobupivacaine level at 30 min was the primary outcome. Pharmacokinetic modeling was performed subsequently. Secondary outcomes included the quality of analgesia, complications, and patients'mobility. RESULTS: Plasma concentrations were similar 30 min after application-0.389 mg × L-1 in the epidural and 0.318 mg × L-1 in the subpleural group (p = 0.33) and lower in the subpleural group at 120 min (p = 0.03). The areas under the curve but not maximum concentrations were lower in the subpleural group. The time to reach maximum plasma level was similar in both groups-27.6 vs. 24.2 min. No clinical symptoms of local anesthetic toxicity were recorded. CONCLUSIONS: Levobupivacaine systemic concentrations were low in both groups without the symptoms of toxicity. This dosage should be safe for postoperative analgesia after thoracotomy.
- Publikační typ
- časopisecké články MeSH
Videolaryngoscopes may reduce cervical spine movement during tracheal intubation in patients with neck trauma. This manikin study aimed to compare the performance of disposable non-channeled and channeled blades of the King Vision™ videolaryngoscope in simulated cervical spine injury. Fifty-eight anesthesiologists in training intubated the TruMan manikin with the neck immobilized using each blade in a randomized order. The primary outcome was the time needed for tracheal intubation, secondary aims included total success rate, the time required for visualization of the larynx, number of attempts, view of the vocal cords, and subjective assessment of both methods. Intubation time with the channeled blade was shorter, with a median time of 13 s (IQR 9-19) vs. 23 s (14.5-37.5), p < 0.001, while times to visualization of the larynx were similar in both groups (p = 0.54). Success rates were similar in both groups, but intubation with the non-channeled blade required more attempts (1.52 vs. 1.05; p < 0.001). The participants scored the intubation features of the channeled blade significantly higher, while visualization features were scored similarly in both groups. Both blades of the King Vision™ videolaryngoscope are reliable intubation devices in a simulated cervical spine injury in a manikin model when inserted by non-experienced operators. The channeled blade allowed faster intubation of the trachea.
- Publikační typ
- časopisecké články MeSH