Single-drop extraction
Dotaz
Zobrazit nápovědu
OBJECTIVE: The aim of the present systematic review was to investigate the effects of voluntary walking interventions in persons with multiple sclerosis (pwMS). For this purpose, we developed a framework to describe the components of walking interventions. DATA SOURCES: Two databases (MEDLINE/PubMed and EMBASE) were searched in January 2023. STUDY SELECTION: Included studies enrolled pwMS and evaluated walking interventions with a duration of 2 weeks or longer. Further, they evaluated at least one walking-related outcome. Both RCTs and non-controlled studies were enrolled. DATA EXTRACTION: Data were extracted using a customized spreadsheet, which included detailed information on patient characteristics, interventions, outcomes, and results. Based on the extracted results, the effect sizes (ES, Hedge's g) of the walking interventions were calculated if possible. The methodological quality of the included studies and their reporting was determined using the TESTEX evaluation tool. DATA SYNTHESIS: Data from a total of n = 200 pwMS was included from N = 7 RCT ́s (from 3 we used within-group data) and N = 5 single-group studies. On average 91.7 ± 9.9 % of the planned walking sessions were attended, 8.7 ± 10.5 % of the participants dropped out, and very few adverse events occurred. Walking interventions improved walking performance during short distance walk tests (ES ranging from -0.21 to -0.72, "walking time") and long distance walk tests (ES ranging from 0.27 to 0.72, "walking distance"). CONCLUSIONS: Voluntary walking interventions appear to be safe and effective at improving walking performance in pwMS. However, well-powered walking intervention studies are needed to confirm these promising effects. The simplicity of walking interventions makes them highly relevant for ambulatory pwMS.
- MeSH
- chůze MeSH
- lidé MeSH
- roztroušená skleróza * terapie MeSH
- test chůzí MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
- systematický přehled MeSH
The review presents an evaluation of the development of on-line, at-line and in-line sample treatment coupled with capillary and microchip electrophoresis over the last 10 years. In the first part, it describes different types of flow-gating interfaces (FGI) such as cross-FGI, coaxial-FGI, sheet-flow-FGI, and air-assisted-FGI and their fabrication using molding into polydimethylsiloxane and commercially available fittings. The second part deals with the coupling of capillary and microchip electrophoresis with microdialysis, solid-phase, liquid-phase, and membrane based extraction techniques. It mainly focuses on modern techniques such as extraction across supported liquid membrane, electroextraction, single drop microextraction, head space microextraction, and microdialysis with high spatial and temporal resolution. Finally, the design of sequential electrophoretic analysers and fabrication of SPE microcartridges with monolithic and molecularly imprinted polymeric sorbents are discussed. Applications include the monitoring of metabolites, neurotransmitters, peptides and proteins in body fluids and tissues to study processes in living organisms, as well as the monitoring of nutrients, minerals and waste compounds in food, natural and wastewater.
- MeSH
- elektroforéza kapilární metody MeSH
- elektroforéza mikročipová * metody MeSH
- mikrodialýza MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
Two operational modes for Lab-In-Syringe automation of direct-immersion single-drop microextraction have been developed and critically compared using lead in drinking water as the model analyte. Dithizone was used in the presence of masking additives as a sensitive chromogenic complexing reagent. The analytical procedure was carried out inside the void of an automatic syringe pump. Normal pump orientation was used to study extraction in a floating drop of a toluene-hexanol mixture. Placing the syringe upside-down allowed the use of a denser-than-water drop of chloroform for the extraction. A magnetic stirring bar was placed inside the syringe for homogenous mixing of the aqueous phase and enabled in-drop stirring in the second configuration while resulting in enhanced extraction efficiency. The use of a syringe as the extraction chamber allowed drop confinement and support by gravitational differences in the syringe inlet. Keeping the stirring rates low, problems related to solvent dispersion such as droplet collection were avoided. With a drop volume of 60 µL, limits of detection of 75 nmol L-1 and 23 nmol L-1 were achieved for the floating drop extraction and the in-drop stirring approaches, respectively. Both methods were characterized by repeatability with RSD typically below 5%, quantitative analyte recoveries, and analyte selectivity achieved by interference masking. Operational differences were critically compared. The proposed methods permitted the routine determination of lead in drinking water to be achieved in less than 6 min.
... -- In Eucaryotic Cells the Genetic Material Is Packaged in Complex Ways 26 -- Summary 27 -- From Single ... ... Cells to Multicellular Organisms 28 -- Single Cells Can Associate to Form Colonies 28 -- The Cells of ... ... Polypeptide Domains -- Protein Subunits Can Self-assemble into Large 84 Structures in the Cell -- A Single ... ... by SDS Polyacrylamide-Gel -- Electrophoresis 173 -- More Than 1000 Proteins Can Be Resolved on a Single ... ... Are Mediated by Random Collisions in the Bilayer Between Diffusing Donors and Acceptors -- A Large Drop ...
xxxix, 1146 s. : il., tab. ; 28 cm
- MeSH
- biologie buňky MeSH
- molekulární biologie MeSH
- Publikační typ
- monografie MeSH
- Konspekt
- Biochemie. Molekulární biologie. Biofyzika
- NLK Obory
- biologie
- cytologie, klinická cytologie