dADSL Dotaz Zobrazit nápovědu
OBJECTIVES: Adenylosuccinate lyase deficiency (dADSL) is a rare inherited metabolic disorder. Biochemical diagnosis of the disease is based on the determination of enormously elevated urinary levels of succinylaminoimidazole carboxamide riboside (SAICA-riboside) and succinyladenosine (SAdo). We report a case of false negative screening for dADSL caused by deribosylation of the urinary biomarkers SAICA-riboside and SAdo. DESIGN AND METHODS: A thin-layer chromatography (TLC) method with Pauly reagent detection of SAICA-riboside was used as a screening method. High-performance liquid chromatography with diode-array detection (HPLC-DAD) and LC-MS/MS methods were used for the identification and quantitative determination of SAICA-riboside, SAdo, succinylaminoimidazole carboxamide (SAICA) and succinyladenine (SA). RESULTS: Following a negative TLC screening in a known case of dADSL, we analyzed urine using HPLC-DAD. The concentration of SAICA-riboside was 2.7mmol/mol creatinine (below the TLC detection limit), and we detected the two abnormal metabolites identified by LC-MS/MS as SAICA and SA. We showed that SAICA and SA were produced by deribosylation of SAICA-riboside and SAdo in the patient's urine. Studies performed by monitoring the production of SAICA and SA after the addition of SAICA-riboside and SAdo to the patient's urine and to urine samples from patients with urinary tract infections suggested that deribosylation is facilitated by bacterial enzymes. CONCLUSIONS: Screening methods for the diagnosis of dADSL may be falsely negative due to bacteria-mediated deribosylation of SAICA-riboside and SAdo. HPLC-DAD or LC-MS/MS analyses allowing for simultaneous detection of SAICA-riboside, SAdo and their deribosylation products SAICA and SA should be preferentially used for the diagnosis of dADSL in urine.
- MeSH
- adenosin analogy a deriváty moč MeSH
- adenylsukcinátlyasa nedostatek moč MeSH
- aminoimidazolkarboxamid analogy a deriváty metabolismus moč MeSH
- bakteriální proteiny metabolismus MeSH
- chromatografie na tenké vrstvě metody MeSH
- Enterococcus faecalis MeSH
- enzymy metabolismus MeSH
- falešně negativní reakce MeSH
- Klebsiella pneumoniae MeSH
- lidé MeSH
- moč mikrobiologie MeSH
- poruchy metabolismu purinů a pyrimidinů diagnóza moč MeSH
- předškolní dítě MeSH
- ribonukleosidy metabolismus moč MeSH
- tandemová hmotnostní spektrometrie metody MeSH
- vysokoúčinná kapalinová chromatografie MeSH
- Check Tag
- lidé MeSH
- předškolní dítě MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
OBJECTIVES: Stable isotope dilution coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) is the sensitive method for screening for various inherited metabolic disorders using dried blood spots (DBSs). We present a method for LC-MS/MS determination of succinyladenosine (SAdo) and succinylaminoimidazole carboxamide riboside (SAICAr), biomarkers for adenylosuccinate lyase deficiency (dADSL), in DBS. DESIGN AND METHODS: SAICAr and SAdo were separated on a Symmetry-C18 column and detected using positive electrospray ionisation in selected reaction monitoring mode. The quantification was performed using the isotopically labelled internal standards SAdo-(13)C4 and SAICAr-(13)C4, which were prepared via ADSL-catalysed reactions of fumarate-(13)C4 with adenosine monophosphate and aminoimidazole carboxamide ribotide, respectively, and subsequent alkaline phosphatase-catalysed dephosphorylation of the resulting products. RESULTS: The detection of SAICAr and SAdo in DBS was linear over the range of 0-25μmol/L. The respective intra-assay and inter-assay imprecision values were less than 10.7% and 15.2% for SAICAr and 4.7% and 5.7% for SAdo. The recoveries from DBS spiked with different concentrations of SAICAr and SAdo were between 94% and 117%. The concentrations of SAICAr and SAdo were higher in the archived DBS from dADSL patients (SAICAr, 0.03-4.7μmol/L; SAdo, 1.5-21.3μmol/L; n=5) compared to those of the control subjects (SAICAr, 0-0.026μmol/L; SAdo, 0.06-0.14μmol/L; n=31), even after DBSs from dADSL patients were stored for 2-23years. CONCLUSIONS: We developed and validated a method of succinylpurine analysis in DBS that improves selective screening for dADSL in the paediatric population and may be used for retrospective diagnosis to aid the genetic counselling of affected families.
- MeSH
- adenosin analogy a deriváty krev MeSH
- adenylsukcinátlyasa krev nedostatek MeSH
- aminoimidazolkarboxamid analogy a deriváty krev MeSH
- chromatografie kapalinová MeSH
- izotopy uhlíku MeSH
- lidé MeSH
- limita detekce MeSH
- novorozenec MeSH
- poruchy metabolismu purinů a pyrimidinů krev diagnóza MeSH
- referenční standardy MeSH
- ribonukleosidy krev MeSH
- tandemová hmotnostní spektrometrie metody MeSH
- test suché kapky krve metody MeSH
- Check Tag
- lidé MeSH
- novorozenec MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH