OBJECTIVES: To assess, in spondyloarthritis (SpA), the discriminative value of the Outcome Measures in Rheumatology (OMERACT) ultrasound lesions of enthesitis and their associations with clinical features in this population. METHODS: In this multicentre study involving 20 rheumatology centres, clinical and ultrasound examinations of the lower limb large entheses were performed in 413 patients with SpA (axial SpA and psoriatic arthritis) and 282 disease controls (osteoarthritis and fibromyalgia). 'Active enthesitis' was defined as (1) power Doppler (PD) at the enthesis grade ≥1 plus entheseal thickening and/or hypoechoic areas, or (2) PD grade >1 (independent of the presence of entheseal thickening and/or hypoechoic areas). RESULTS: In the univariate analysis, all OMERACT lesions except enthesophytes/calcifications showed a significant association with SpA. PD (OR=8.77, 95% CI 4.40 to 19.20, p<0.001) and bone erosions (OR=4.75, 95% CI 2.43 to 10.10, p<0.001) retained this association in the multivariate analysis. Among the lower limb entheses, only the Achilles tendon was significantly associated with SpA (OR=1.93, 95% CI 1.30 to 2.88, p<0.001) in the multivariate analyses. Active enthesitis showed a significant association with SpA (OR=9.20, 95% CI 4.21 to 23.20, p<0.001), and unlike the individual OMERACT ultrasound lesions it was consistently associated with most clinical measures of SpA disease activity and severity in the regression analyses. CONCLUSIONS: This large multicentre study assessed the value of different ultrasound findings of enthesitis in SpA, identifying the most discriminative ultrasound lesions and entheseal sites for SpA. Ultrasound could differentiate between SpA-related enthesitis and other forms of entheseal pathology (ie, mechanical enthesitis), thus improving the assessment of entheseal involvement in SpA.
- MeSH
- Achillova šlacha diagnostické zobrazování patologie MeSH
- dospělí MeSH
- entezopatie * diagnostické zobrazování MeSH
- lidé středního věku MeSH
- lidé MeSH
- psoriatická artritida diagnostické zobrazování komplikace MeSH
- spondylartritida * diagnostické zobrazování komplikace MeSH
- studie případů a kontrol MeSH
- stupeň závažnosti nemoci MeSH
- ultrasonografie dopplerovská * metody MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
Závěrečná zpráva o řešení grantu Agentury pro zdravotnický výzkum MZ ČR
nestr.
Hypotéza: Muskuloskeletální ultrasonografie (MSUS) dětí s juvenilní idiopatickou artritidou (JIA) umožní identifikaci subklinické synovitidy i strukturálního poškození kloubů a významně přispěje k monitoraci onemocnění a optimalizaci terapie při menší zátěži pacienta i zdravotnického systému. Senzitivita MSUS pro synovitidu může mít srovnatelnou výpovědní hodnotu s magnetickou rezonancí (MR). Hlavní cíle: Zavedení a standardizace MSUS kloubů u dětí s JIA. Stanovení spektra fyziologických nálezů na MSUS. Stanovení klinické významnosti MSUS změn, standardizace hodnocení patologických nálezů. Definice sonografických parametrů kloubní remise. Metody: MSUS bude prováděna dvěma školenými operátory: u pacientů bez kloubního onemocnění v 6 věkových kategoriích a u pacientů s jakýmkoli podtypem aktivní JIA. Srovnání MSUS nálezů na klinicky aktivních kloubech dětí s JIA a na zdravých kloubech kontrol stejného věku. Porovnání klinického kloubního nálezu s MSUS a MR, korelace se standardizovanými parametry aktivity JIA, funkčního omezení a kvality života (JADAS, JAMAR, PedsQL, CHAQ).; Hypothesis: The identification of subclinical synovitis and structural damage in the joints by musculoskeletal ultrasonography (MSUS) in children with juvenile idiopathic arthritis (JIA) will contribute to the monitoring and optimizing of therapy with less burden for the patient and healthcare system. MSUS sensitivity for synovitis may have predictive value as MR imaging. Main objectives: The introduction and standardization MSUS of joints in children with JIA. Determining the range of MSUS physiological findings. Determining the clinical significance of MSUS changes and standardization of pathological findings. MSUS criteria for the remission in joint. Methods: MSUS will be performed by two trained operators: in patients without joint disease in six age-related categories and in patients with any subtype of active JIA. Comparison MSUS findings in clinically active joints in JIA and joints of healthy controls of the same age. Comparison of the clinical findings in joints with MSUS and MR and correlation with standardized parameters JIA activity, functional limits, quality of life.
- MeSH
- dítě MeSH
- juvenilní artritida diagnostické zobrazování MeSH
- kloubní chrupavka MeSH
- magnetická rezonanční tomografie MeSH
- synovitida diagnostické zobrazování MeSH
- ultrasonografie dopplerovská metody MeSH
- zánět MeSH
- Check Tag
- dítě MeSH
- Konspekt
- Pediatrie
- NLK Obory
- pediatrie
- ortopedie
- revmatologie
- NLK Publikační typ
- závěrečné zprávy o řešení grantu AZV MZ ČR
OBJECTIVES: To investigate the reliability of the OMERACT US Task Force definition of US enthesitis in SpA. METHODS: In this web exercise, based on the evaluation of 101 images and 39 clips of the main entheses of the lower limbs, the elementary components included in the OMERACT definition of US enthesitis in SpA (hypoechoic areas, entheseal thickening, power Doppler signal at the enthesis, enthesophytes/calcifications, bone erosions) were assessed by 47 rheumatologists from 37 rheumatology centres in 15 countries. Inter- and intra-observer reliability of the US components of enthesitis was calculated using Light's kappa, Cohen's kappa, Prevalence And Bias Adjusted Kappa (PABAK) and their 95% CIs. RESULTS: Bone erosions and power Doppler signal at the enthesis showed the highest overall inter-reliability [Light's kappa: 0.77 (0.76-0.78), 0.72 (0.71-0.73), respectively; PABAK: 0.86 (0.86-0.87), 0.73 (0.73-0.74), respectively], followed by enthesophytes/calcifications [Light's kappa: 0.65 (0.64-0.65), PABAK: 0.67 (0.67-0.68)]. This was moderate for entheseal thickening [Light's kappa: 0.41 (0.41-0.42), PABAK: 0.41 (0.40-0.42)], and fair for hypoechoic areas [Light's kappa: 0.37 (0.36-0.38); PABAK: 0.37 (0.37-0.38)]. A similar trend was observed in the intra-reliability exercise, although this was characterized by an overall higher degree of reliability for all US elementary components compared with the inter-observer evaluation. CONCLUSIONS: The results of this multicentre, international, web-based study show a good reliability of the OMERACT US definition of bone erosions, power Doppler signal at the enthesis and enthesophytes/calcifications. The low reliability of entheseal thickening and hypoechoic areas raises questions about the opportunity to revise the definition of these two major components for the US diagnosis of enthesitis.
- MeSH
- lidé MeSH
- ultrasonografie dopplerovská metody přístrojové vybavení MeSH
- ultrasonografie * metody přístrojové vybavení MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- přehledy MeSH
Cíle: Cílem práce bylo zjistit, zda existuje ve skupině hypertenzních glaukomů (HTG) korelace mezi vessel density (VD) a výsledky naměřených průtokových hodnot v arteria ophtalmica a v arteria centralis retinae stejného oka. Materiál a metody: Soubor tvořilo 20 nemocných HTG, z toho 13 žen průměrného věku 68,7 let (49–80 let) a 7 mužů průměrného věku 58,4 let (27–81 let). Kritéria pro zařazení do studie: zraková ostrost 1,0 s případnou korekcí menší než ±3 dioptrie, přibližně stejné změny v zorných polích u všech nemocných, nitrooční tlak (NOT) menší než 18 mmHg, žádné jiné oční a neurologické onemocnění. VD byla změřena pomocí Avanti RTVue XR firmy Optovue, perfuzní parametry pomocí Dopplerovské sonografie na přístroji Affinity 70G firmy Philips. Byla změřena maximální rychlost v systole (PSV) a konečná v diastole (EDV) a rezistenční index (RI) jak v arteria centralis retinae (ACR), tak v arteria ophtalmica (AO). Zorné pole (VF) bylo vyšetřeno rychlým prahovým glaukomovým programem přístrojem Medmont M700. Součet citlivostí v apostilbech (asb) byl hodnocen v rozsahu 0–22 stupňů zorného pole. Výsledky citlivostí v zorném poli byly pak porovnány s VD a průtokovými parametry ACR a AO stejného oka. Výsledky: Pro posouzení závislosti mezi vybranými parametry byl použit Pearsonův korelační koeficient. Porovnáním VF a VD z měřených oblastí ukázal na silnou korelaci (r = 0,64, resp. 0,65). Dále bylo prokázáno, že VD (WI-VDs) koreluje s RIACR slabě (r = -0,35) a středně silně (WI-VDa r = -0,4 a PP-VDs r = -0,43 a PP-VDa r = -0,45). To znamená, že se zvyšujícím se rezistenčním indexem v ACR se snižuje i hustota VD. Ostatní korelace mezi VD a perfuzními parametry (PSV a EDV) v ACR a AO byly nevýznamné. Závěr: Naměřené hodnoty ukázaly, že na změny v zorných polích u HTG má vaskulární složka VD velký vliv. Slabý až střední vliv existuje mezi VD a RI v ACR. Pro zjištění stavu prokrvení oka je vhodnější OCTA než Dopplerovská sonografie cév.
Aims: The main aim of this work was to find out if there is a correlation between vessel density (VD) and results of measured perfusion values in ophthalmic artery and in central retinal artery of the same eye in a group with hypertension glaucoma (HTG). Materials and methods: The file included 20 patients with HTG, thereof 13 women of average age 68.7 years (49–80 years) and 7 men of average age 58.4 years (27–81 years). Criteria for inclusion in the study: visual acuity 1,0 with possible correction less than ±3 diopters, approximately the same changes in visual fields in every patient, intraocular pressure (IOP) less than 18 mmHg, no other ocular or neurological diseases. VD was measured by Avanti RTVue XR by Optovue firm, perfusion parameters were measured using Doppler ultrasound with Affinity 70G machine by Philips firm. The peak systolic velocity (PSV) and end diastolic velocity (EDV) and resistance index (RI) were measured both in ophthalmic artery (AO) and in central retinal artery (CRA). Visual field (VF) was examined by quick threshold glaucoma program by Medmont M 700 machine. The sum of sensitivities in apostilbs (abs) was evaluated in the range 0–22 degrees of visual field. The results of sensitivities in visual field were compared to VD and perfusion parameters in CRA and AO of the same eye. Results: Pearson’s correlation coefficient (p = 0,05) was used to assess the dependency between chosen parameters. By comparing VF and VD from measured areas, strong correlation (r = 0.64, resp. 0.65) was revealed. It was then proved that VD (WI-VDs) correlates with RICRA weakly (r = -0.35) and moderately strongly (WI-VDa r = -0.4, PP-VDs r = -0.43 and PP-VDa r = -0.45). This means that with increasing resistance index in CRA the density in VD decreases. The other correlations between VD and perfusion parameters (PSV and EDV) in CRA and AO were not significant. Conclusion: Measured values showed that the vascular component of VD has a huge impact on the changes in visual fields in HTG. Weak to moderate influence exists between VD and RI in CRA. OCTA has proven to be more suitable than Doppler ultrasound for determining the condition of blood circulation in the eye.
Cíle: Cílem práce bylo ověřit existenci korelace mezi hustotou cév a průtokovými hodnotami v arteria oftalmica a arteria centralis retinae stejného oka u pacientů s diagnostikovaným normotenzním glaukomem (NTG). Materiál a metody: Soubor tvořilo 20 pacientů s NTG, z toho 17 žen (průměrný věk 56,1 let) a 3 muži (průměrný věk 60 let). Kritéria pro zařazení do studie obsahovala: zraková ostrost 1,0 s korekcí menší než ±3 D, přibližně stejné změny v zorných polích, diagnóza počínajícího NTG potvrzena elektrofyziologickým vyšetřením, žádné jiné oční a neurologické onemocnění. Parametr vessel density (VD) jsme stanovili pomocí Avanti RTVue XR (Optovue), perfuzní parametry dopplerovskou sonografií (Affinity 70G Philips, sonda 5–12 MHz). Byla měřena maximální rychlost v systole (PSV), konečná v diastole (EDV) i resistenční index (RI) v arteria oftalmica (AO) i arteria centralis retinae (ACR). Zorné pole bylo vyhodnoceno dle glaukomového testu s rychlou prahovou strategií (Medmont M700). Součet citlivostí v apostilbech (asb) byl hodnocen v rozsahu 0–22 stupňů zorného pole. Výsledky citlivostí v zorném poli byly porovnány s VD a měřenými průtokovými parametry. Výsledky: Pro posouzení závislosti mezi vybranými parametry byl použit Pearsonův korelační koeficient. Z naměřených průměrných hodnot lze stanovit, že na změnách v zorných polích se podílí hlavně peripapilární VD a také všechny cévy z celé měřené oblasti. Pro vztah mezi VD a průtokovými parametry ACR a AO, byla zjištěna střední nepřímá korelace PSV u AO s peripapilární VD všech cév (r = -0,49), malých cév (r = -0,46) i s VD celé měřené oblasti (r = -0,45). Podobný korelační vztah byl zaznamenán v případě EDV u AO s peripapilární VD všech cév (r = -0,41), malých cév (r = -0,41) a celé měřené oblasti (r = -0,42). Ostatní korelace mezi VD a průtokovými parametry byly nevýznamné. Závěr: Naše nálezy potvrzují, že na změnách v zorných polích se větší mírou podílí hlavně vaskulární složka VD než perfuzní parametry, zejména u AO. Perfuze v ACR nehraje u NTG ve změnách v zorném poli signifikantní roli.
Aims: To investigate the dependence of blood vessel density and velocity in ophthalmic artery and arteria centralis retinae of the same eye in patients with normotensive glaucoma. Methods: The sample consisted of 20 patients with normotensive glaucoma (NTG). There were 17 women (mean age 56.1) and 3 men (mean age 60 years). Inclusion criteria for study: visual acuity 1.0 with correction up to ±3 dioptres, approximately equal changes in the visual field, whereby it was incipient NTG and diagnosis was confirmed by electrophysiological examination, without further ocular or neurological disease. Parameters of vessel density (VD) were evaluated by Avanti RTVue XR (Optovue). Perfusion parameters such as peak systolic velocity (PSV), end diastolic velocity (EDV) and resistive index (RI) were evaluated for ophthalmic artery (AO) and arteria centralis retinae (ACR) using Doppler sonography (Affinity 70G Philips, probe 5–12 MHz). Visual field (VF) was evaluated by automated perimeter (Medmont M700) using fast threshold glaucoma strategy test. The sum of sensitivity levels in apostilb (asb) were evaluated in range 0–22 degrees of visual field. Resulting values of VF were compared with VD and perfusion parameters in AO and ACR at the same eye. Results: Pearson’s correlation coefficient was used to evaluate the dependence. Data shows, that changes in visual fields are mainly caused by peripapillary VD of small and all vessels, and vessels throughout measured image area also. Correlation of small vessels throughout measured image area was weak (r = 0.23). Moderate negative correlation was found for PSV in AO and peripapillary small VD (r = -0.46), all peripapillary VD (r = -0.49), VD in whole area (r = -0.45), then between EDV in AO and VD in whole area (r = -0.42). Other correlations between VD and perfusion parameter were insignificant. Conclusions: Study confirms, that changes of visual field in NTG patients are mainly caused by VD rather than perfusion parameters, especially in AO. Perfusion parameters in ACR are not significantly correlated with changes of VF in NTG patients.
- Klíčová slova
- hustota cév,
- MeSH
- CT angiografie metody MeSH
- dospělí MeSH
- klinická studie jako téma MeSH
- lidé středního věku MeSH
- lidé MeSH
- normotenzní glaukom * diagnostické zobrazování patologie MeSH
- senioři MeSH
- ultrasonografie dopplerovská metody MeSH
- zraková pole MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
Cíl studie: Cílem studie je zhodnocení efektivity rutinního ultrazvukového screeningu růstové restrikce ve třetím trimestru gravidity. Typ studie: Původní práce. Název a sídlo pracoviště: Gynekologicko-porodnické oddělení, Oblastní nemocnice Příbram. Metodika: Hodnocení vlivu normálního resp. abnormálního výsledku rutinního ultrazvukového screeningu růstové restrikce ve třetím trimestru gravidity na výskyt hypoxie v průběhu porodu. Výskyt abnormálních dopplerovských parametrů v jednotlivých biometrických kohortách. Hodnocení retrospektivních dat za rok 2019. Výsledky: Na našem pracovišti jsme od roku 2016 provedli vyšetření biometrie a vyšetření dopplerovské kolem 36. týdne u většiny těhotných. Zajímavým zjištěním byl nález jednoznačně abnormálních dopplerovských parametrů u patnácti "eutrofických" gravidit nad 10. percentilem. Zároveň se u 20 % plodů mezi 10. a 20. percentilem s původně normálními dopplerovskými parametry vyvinuly následně patologické parametry a/nebo plody stagnovaly v růstu. Všechny tyto gravidity byly spojeny s významným výskytem hypoxie v průběhu porodu. Závěr: Považujeme za přínosné vyšetření dopplerovských parametrů u všech plodů pod 20. percentilem, jejich dispenzarizaci a v případě stagnace růstu a/nebo zhoršení průtokových parametrů včasné ukončení gravidity.
Objective: The aim of the study is to evaluate the efficiency of routine ultrasound screening of fetal growth restriction in third trimester of pregnancy. Design: Original paper. Setting: Department of Obstetrics and Gynecology, Regional Hospital Příbram. Methods: Evaluation of the impact of normal or abnormal result of routine ultrasound screening of fetal growth restriction in third trimester of pregnancy on the incidence of hypoxia during labour. Incidence of abnormal Doppler parameters in an individual biometric cohorts. Evaluation of retrospective dates from year 2019. Results: In our department, we measure fetal biometry and Doppler parameters routinely in majority of pregnant women about 36. weeks of gestation, from year 2016. An interesting finding was detection of a definite abnormal Doppler parameters in 15 "eutrophic" pregnancies above the 10th centile. Equally 20 % of all fetuses between 10th and 20th centile with initially normal Doppler parameters developed subsequently patologic parameters and/or growth stagnation. All of these pregnancies were associated with high proportion of hypoxia during labour. Conclusion: We consider benefit from examination Doppler parameters in all fetuses under the 20th centile, their dispensarisation, and in case of growth- stagnation or/and Doppler worsening, prompt pregnancy termination.
- MeSH
- biometrie metody MeSH
- hypoxie plodu diagnostické zobrazování MeSH
- lidé MeSH
- retrospektivní studie MeSH
- růstová retardace plodu * diagnostické zobrazování MeSH
- těhotenství MeSH
- ultrasonografie dopplerovská metody MeSH
- ultrasonografie prenatální metody MeSH
- Check Tag
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
OBJECTIVE: To evaluate the intraobserver and interobserver reliability of the ultrasonographic (US) assessment of subtalar joint (STJ) synovitis in patients with rheumatoid arthritis (RA). METHODS: Following a Delphi process, 12 sonographers conducted an US reliability exercise on 10 RA patients with hindfoot pain. The anteromedial, posteromedial, and posterolateral STJ was assessed using B-mode and power Doppler (PD) techniques according to an agreed US protocol and using a 4-grade semiquantitative grading score for synovitis [synovial hypertrophy (SH) and signal] and a dichotomous score for the presence of joint effusion (JE). Intraobserver and interobserver reliability were computed by Cohen's and Light's κ. Weighted κ coefficients with absolute weighting were computed for B-mode and PD signal. RESULTS: Mean weighted Cohen's κ for SH, PD, and JE were 0.80 (95% CI 0.62-0.98), 0.61 (95% CI 0.48-0.73), and 0.52 (95% CI 0.36-0.67), respectively. Weighted Cohen's κ for SH, PD, and JE in the anteromedial, posteromedial, and posterolateral STJ were -0.04 to 0.79, 0.42-0.95, and 0.28-0.77; 0.31-1, -0.05 to 0.65, and -0.2 to 0.69; 0.66-1, 0.52-1, and 0.42-0.88, respectively. Weighted Light's κ for SH was 0.67 (95% CI 0.58-0.74), 0.46 (95% CI 0.35-0.59) for PD, and 0.16 (95% CI 0.08-0.27) for JE. Weighted Light's κ for SH, PD, and JE were 0.63 (95% CI 0.45-0.82), 0.33 (95% CI 0.19-0.42), and 0.09 (95% CI -0.01 to 0.19), for the anteromedial; 0.49 (95% CI 0.27-0.64), 0.35 (95% CI 0.27-0.4), and 0.04 (95% CI -0.06 to 0.1) for posteromedial; and 0.82 (95% CI 0.75-0.89), 0.66 (95% CI 0.56-0.8), and 0.18 (95% CI 0.04-0.34) for posterolateral STJ, respectively. CONCLUSION: Using a multisite assessment, US appears to be a reliable tool for assessing synovitis of STJ in RA.
- MeSH
- delfská metoda MeSH
- dospělí MeSH
- incidence MeSH
- konsensus MeSH
- lidé středního věku MeSH
- lidé MeSH
- reprodukovatelnost výsledků MeSH
- revmatoidní artritida patologie MeSH
- subtalární kloub diagnostické zobrazování patologie MeSH
- synovitida diagnostické zobrazování epidemiologie MeSH
- ultrasonografie dopplerovská metody normy MeSH
- výzkumný projekt MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
- systematický přehled MeSH
BACKGROUND: Ankle brachial index (ABI) is the principal screening method for peripheral arterial disease (PAD). In this study, we compare various types of Doppler-derived and oscillometric ABIs with results obtained through duplex ultrasonography. METHODS: 62 patients were enrolled in the study. For each limb, blood pressures for both ankle arteries and the arm were measured using Doppler and an automated oscillometric device. Duplex ultrasound was performed for all limbs and occlusions >50% were considered PAD-positive. ABI was calculated using both higher (HABP) and lower (LABP) arterial blood pressure on the individual limbs and the ability to predict duplex-detected stenoses was evaluated. RESULTS: LABP calculation provided results superior to the guideline-recommended HABP. Considering patients with ABI >1.4 or measurement failure as PAD-positive further enhanced the test parameters. The higher ABI cut-off of 1.0 resulted in somewhat better sensitivities (max 92%) and negative predictive values (max 87%) at the expense of a substantial increase in the number of false positives. Oscillometric method yielded poor sensitivities but very good specificities (max 94%) and positive predictive values (max 90%). CONCLUSIONS: Doppler-based LABP provides better results than the guideline-recommended HABP in diabetic patients, nevertheless even this method is not perfect. Increasing the cut-off value to 1.0 in these patients does not bring a substantial improvement of the test performance. Patients with high ABI should be automatically considered PAD-positive and referred for further investigation using imaging techniques.
- MeSH
- arteriální okluzní nemoci diagnóza patofyziologie MeSH
- diabetické angiopatie diagnóza patofyziologie MeSH
- krevní tlak fyziologie MeSH
- lidé MeSH
- onemocnění periferních arterií diagnóza patofyziologie MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- tlakový index kotník-paže metody MeSH
- ultrasonografie dopplerovská metody MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
OBJECTIVE: To identify and synthesize the best available evidence on the application of musculoskeletal (MSK) ultrasound (US) in patients with systemic lupus erythematosus (SLE) and to present the measurement properties of US in different elementary lesions and pathologies. METHODS: A systematic literature search of PubMed, Embase, and the Cochrane Library was performed. Original articles were included that were published in English between August 1, 2014, and December 31, 2018, reporting US, Doppler, synovitis, joint effusion, bone erosion, tenosynovitis, and enthesitis in patients with SLE. Data extraction focused on the definition and quantification of US-detected synovitis, joint effusion, bone erosion, tenosynovitis, enthesitis, and the measurement properties of US according to the OMERACT Filter 2.1 instruments selection. RESULTS: Of the 143 identified articles, 15 were included. Most articles were cross-sectional studies (14/15, 93%). The majority of the studies used the OMERACT definitions for ultrasonographic pathology. Regarding the measurement properties of US in different elementary lesions and pathologies, all studies dealt with face validity, content validity, and feasibility. Most studies achieved construct validity. Concerning the reliability of image reading, 1 study (1/15, 7%) assessed both intraobserver and interobserver reliability. For image acquisition, 4 studies (4/15, 27%) evaluated interobserver reliability and none had evaluated intraobserver reliability. Criterion validity was assessed in 1 study (1/15, 7%). Responsiveness was not considered in any of the studies. CONCLUSION: This literature review demonstrates the need for further research and validation work to define the involvement of US as an outcome measurement instrument for the MSK manifestations in patients with SLE.
- MeSH
- dospělí MeSH
- entezopatie diagnostické zobrazování MeSH
- hodnocení výsledků zdravotní péče metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- muskuloskeletální systém diagnostické zobrazování MeSH
- průřezové studie MeSH
- psoriatická artritida diagnostické zobrazování MeSH
- reprodukovatelnost výsledků MeSH
- revmatoidní artritida diagnostické zobrazování MeSH
- studie proveditelnosti MeSH
- stupeň závažnosti nemoci MeSH
- synovitida diagnostické zobrazování MeSH
- systémový lupus erythematodes diagnostické zobrazování MeSH
- tenosynovitida diagnostické zobrazování MeSH
- ultrasonografie dopplerovská metody MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- systematický přehled MeSH