- Publikační typ
- abstrakt z konference MeSH
Mitral regurgitation is the second most frequent valve disease in the adult population. Until recently, surgical repair or replacement were the only therapeutic options, leaving many patients untreated and even underdiagnosed, most frequently due to a presumably high surgical risk, particularly in those with secondary mitral regurgitation. Over the last few years, there has been exponential growth in the number of catheter-based procedures, with most of them using the transcatheter edge-to-edge repair (TEER) technique. Furthermore, the evolution of other systems is under way that preferentially use the transseptal approach, are more comprehensive, and are aimed at transcatheter mitral valve replacement. The purpose of this article is to review the current transcatheter repair systems and the evidence base for their use.
Mitrální regurgitace představuje druhou nejčastější chlopenní vadu v dospělé populaci. Až do nedávné doby byla jedinou terapeutickou možností chirurgická plastika nebo náhrada mitrální chlopně, přičemž mnoho nemocných nebylo léčeno ani diagnostikováno, nejčastěji z důvodů předpokládaného vysokého rizika operace, zejména u nemocných se sekundární mitrální regurgitací. V průběhu několika posledních let došlo k výraznému nárůstu počtu transkatétrových výkonů, většina z nich využívala principu sblížení obou cípů mitrální chlopně (tzv. transkatétrová edge‐to‐edge korekce - TEER). V současnosti jsme svědky vývoje dalších systémů, které využívají prefe
- Klíčová slova
- "edge‐to‐edge" intervence mitrální chlopně,
- MeSH
- kardiochirurgické výkony metody MeSH
- lidé MeSH
- mitrální insuficience * chirurgie MeSH
- srdeční katetrizace metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- přehledy MeSH
Cíl práce: Prokázat u nemocných po první epizodě schizofrenie strukturální změny bílé hmoty mozkové pomod fixel-based analýzy (FBA). Metodika: V prospektivnf studii byly pomod FBA studovány difuzně vážené MR obrazy skupiny pacientů po první epizodě schizofrenie (n = 16) a kontrolní skupiny (n = 22). Vyšetření proběhlo na 3T MR tomografu s využitím 64-kanálové hlavové dvky. FBA byla provedena pomocí softwarového balíku MRtrix (verze 3.0.1). Výsledky: Pomod FBA byl u nemocných prokázán pokles metriky fibre density v oblasti commissura anterior. Nebyly nalezeny statisticky významné oblasti se změnami metriky fibre cross-section. Pro kombinovanou metriku fibre density and cross-section byl nalezen jeden statisticky významný fixel v bílé hmotě frontální části pravostranného centrum semiovale. Závěr: Pomocí FBA byl prokázán u nemocných po první epizodě schizofrenie při srovnání s kontrolním souborem velmi malý rozsah změn v bílé hmotě mozkové. Jejich charakter svědd pro poruchu mikrostruktury bílé hmoty u nemocných. Maximum prokázaných změn leží v commissura anterior. Rozsah nalezených změn je při porovnání s publikovanými pracemi využívajícími FBA výrazně menší, což může být podmíněno mj. časnějším stadiem onemocnění probandů ve vyšetřovaném souboru.
Purpose: To assess white matter changes after the first episode of schizophrenia by using fixel-based analysis (FBA). Methods: Diffusion weighted MR images were used to prospectively compare white matter microstructure between subjects after the first episode of schizophrenia (n = 16) and healthy controls (n = 22). The subjects were examined on a 3 Tesla MRI system equipped with a 64-channel head coil. FBA was performed using MRtrix software package (version 3.0.1). Results: A limited area of fibre density decrease was found in the anterior commissure. No fixels of fibre cross-sedion changes were found. For combined metric of fibre density and cross-sedion only one statistically significant fixel was found in the right frontal white matter. Conclusion: Using FBA, only a limited area of white matter microstructure corruption was found after the first episode of schizophrenia. Changes were located mainly in the anterior commissure. Compared to other published studies using FBA, the extent of changes is distinctly smaller which can be among other causes subjected to earlier stages of the illness of subjects included in this study.
- Klíčová slova
- fixel-based analýza,
- MeSH
- bílá hmota diagnostické zobrazování patologie MeSH
- commissura anterior diagnostické zobrazování patologie MeSH
- lidé MeSH
- magnetická rezonanční tomografie * metody MeSH
- prospektivní studie MeSH
- schizofrenie * diagnostické zobrazování patologie MeSH
- zobrazování difuzních tenzorů metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
Cíl: Ověřit, zda je u pacientů v časném stadiu onemocnění schizofrenií přítomna redukce tloušťky a/nebo plochy neokortexu. Metodika: V prospektivní studii byla pomocí magnetické rezonance zkoumána tloušťka a plocha neokortexu souboru nemocných po první epizodě schizofrenie (n = 15) a kontrolního souboru zdravých jedinců (n = 19). Probandi byli vyšetřeni na 3 T MR tomografu s využitím 64kanálové hlavové cívky. Surface-based morfometrie byla provedena na 3D TI- a T2-vážených obrazech softwarovým balíkem Freesurfer (verze 7.1.0). Výsledky: Nebyly nalezeny statisticky významné clustery změny tloušťky neokortexu ani jeho plochy mezi oběma testovanými skupinami. Závěr: V rozporu s výsledky jiných autorů včetně rozsáhlých multicentrických studií nebyly nalezeny statisticky významné změny tloušťky a plochy neokortexu u nemocných v klinicky nejranějších stadiích schizofrenie.
Purpose: To asses cerebralcorticalthickness and area changes in the earliest stage of schizophrenia. Methods: Magnetic resonance was used to prospectively compare cerebral cortex thickness and surface area between subjects after the first episode of schizophrenia (n = 15) and healthy controls (n = 19). The subjects were examined on a 3 Tesla MRI system equipped with a 64-channel head coil. Surface-based morphometry was performed on 3D T1- and T2-weighted data by using Freesurfer software package (ver. 7.1.0). Results: No statistically significantly different clusters of cerebral cortical surface / thickness were found between both groups of subjects. Conclusion: Contrary to the observations published by other authors including large multicentric studies, no statistically significant differences in cerebral cortical thickness or area were found in the earliest stage of schizophrenia.
Cíl: Cílem práce je ověřit, zda je možné použít Gd-DOTA- (Dotarem) pro zobrazení hyalinní chrupavky pomocí delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC), a nahradit tak Gd-DTPA2- (Magnevist). Metodika: Projekt byl součástí studie zabývající se pooperačními změnami chrupavky kolenního kloubu, MR vyšetření bylo provedeno na přístroji Philips Ingenia 3T, s použitím kolenní cívky (dS knee coil, 8 kanálů), metodou dGEMRIC se sekvencí 3D IR-GRE s rozdílným TI (100, 200, 400, 800 a 1600 ms), voxel: 0,5 x 0,5 x 3 mm3, FOV 160 mm, počet vrstev 40, TR 1800 ms, TE 2 ms, sklápěcí úhel 8°, SENSE faktor 2. Vyšetření bylo provedeno před operací (M0), po 6 měsících (M6) a následně ve 12 (M12) a 18 (M18) měsících od operace. Srovnání bylo provedeno v těchto skupinách pacientů: jedenáct pacientů s Magnevistem při vstupním vyšetření M0 a M6, osm pacientů s Magnevistem v M0 a Dotarem v M6 a šest pacientů s Dotaremem v M0 a rovněž M6 vyšetření. Výsledky: Mediánové hodnoty změny indexu byly podobné ve skupině Magnevist-Magnevist a Dotarem-Dotarem (2,7, resp. 2,4; p = 0,961 před korekcí a 1,000 po korekci na mnohonásobné porovnání). Medián změny indexu ve skupině Magnevist-Dotarem byl vyšší (4,8) ve srovnání se dvěma dalšími skupinami, ale rozdíl nebyl statisticky významný (p = 0,351 a p = 0,662 před korekcí; 1,000 v obou případech po korekci). Závěr: dGEMRIC je možné provést i s využitím Gd-DOTA- (Dotarem), statisticky významný rozdíl ve změně indexu podle kontrastních látek (p = 0,637) nebyl prokázán.
Aim: The aim of this project is to assess the feasibility Gd-DOTA- (Dotarem) for imaging of hyalinne cartilage using delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) to replace Gd-DTPA2- (Magnevist). Methods: The project was a part of a study of postoperative cartilage changes. MR examination was performed on a Philips Ingenia 3T using a 8-channels dS knee coil, dGEMRIC 3D IR-GRE sequence with five different inversion times (100, 200, 400, 800 and 1600 ms), voxel: 0.5 x 0.5 x 3 mm3, FOV 160 mm, 40 slices, TR 1800 ms, TE 2 ms, 8° flip angle, SENSE factor 2. The baseline examination was performed before surgery (M0), 6 months (M6), 12 (M12) and 18 (M18) months after surgery. Comparisons were made in these groups of patients: 11 patients with Magnevist at initial examination M0 and M6, 8 patients with Magnevist at M0 and Dotarem in M6, and finally 6 patients with Dotarem at M0 and also M6 examination. Results: The median values of the index change were similar in the Magnevist-Magnevist and Dotarem-Dotarem groups (2.7 and 2.4, respectively, p = 0.961 before correction and 1.000 after correction for multiple comparisons). The median index change in the Magnevist-Dotarem group was higher (4.8) compared to the two other groups, but the difference was not statistically significant (p = 0.351 and p = 0.662 before correction; 1.000 in both cases after correction). Conclusion: dGEMRIC is feasible using Gd-DOTA- (Dotarem), there was no statistically significant difference (p = 0. 637) between the two types of contrast media.
Cíl: Metoda fázového kontrastu se používá pro měření toku zejména krve. Trpí ovšem několika zdroji chyb, mezi něž patří efekt částečného objemu (partial volume effect - PVE), šum a nejistota ve výběru oblasti zájmu (region of interest - ROI). Cílem této studie bylo chybu z těchto tří zdrojů kvantifikovat a případně navrhnout doporučení jak chybu minimalizovat. Metodika: Na průtokovém fantomu byl měřen tok vody plastovou trubicí pro několik hodnot průtoku a různé prostorové rozlišení, které má vliv na závažnost efektu částečného objemu. Poměr signál/šum (signal-to-noise ratio - SNR) magnitudových obrazů byl použitý pro odhad chyby způsobené šumem a ta byla porovnána se statistickou chybou stanovenou z opakovaného měření. In vitro a in vivo na aortální chlopni a v sinotubulární junkci byl měřen průtok podhodnocenými a nadhodnocenými oblastmi zájmu. Výsledky: Efekt částečného objemu slábne s lepším prostorovým rozlišením a menším rozdílem v magnitude signálu z tekoucí a statické tkáně. Pro měření na aortální chlopni odhadujeme chybu na 0,45 %. Šum má na velikost náhodné chyby, kterou odhadujeme na 0,05 %, menší vliv než fluktuace toku (0,25 %). Podhodnocení ROI může vést k závažnému podhodnocení toku (nad 10 %), malé podhodnocení v případě aortální chlopně k mírnému nadhodnocení (5 %). Nadhodnocení ROI taktéž vede k chybě (6 %), ovšem obecně menší než podhodnocení. Závěr: Ze tří zkoumaných jevů je nejvýznamnější způsob výběru ROI, kterou doporučujeme spíše nadhodnotit než podhodnotit. Chyba z PVE je v porovnání s chybou z výběru ROI malá. Chyba z šumu je zanedbatelná, větší roli než šum hrají fluktuace toku.
Objective: Phase contrast sequence may be used to measure the flux of blood in vessels. The result might be, however, corrupted by many errors including partial volume effect (PVE), region of interest (ROI) contouring, and noise. In this study we aim to quantify the error and if possible to suggest a proper strategy to minimize it. Methods: Water flux was measured using a plastic flow phantom and changing the flow rate and spatial resolution which affects the PVE error. Signal-to-noise ratio (SNR) of magnitude images was used to estimate error caused by noise and a comparison to a statistical error from several measurements was made. Water flux in vitro and flux through aortal valve and sinotubular junction in vivo was also measured with undersized and oversized ROIs. Results: The PVE subsides as spatial resolution improves and as the difference between magnitude signal from flowing and static tissue decreases. The error of flow through aortal valve was estimated to be 0.45%. Noise affects random error (estimation 0.05%) less then flow fluctuations (0.25%). The ROI size underestimation may lead to a severe underestimation of flow (over 10%) and a small underestimation in the case of aortal valve flow to a mild overestimation (5%). In general, an overestimation of ROI size is also erroneous (6%), although not as severe as underestimation. Conclusion: The most relevant source of error out of the three sources examined is ROI contouring with overestimation being recommended over underestimation. The error resulting from the PVE is small compared to ROI contouring error. The error caused by noise is negligible compared to flow fluctuation.
- MeSH
- chybná diagnóza MeSH
- lidé MeSH
- magnetická rezonanční tomografie * MeSH
- poměr signál - šum MeSH
- reologie krve * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- klinická studie MeSH
- práce podpořená grantem MeSH
Cíl: Vyvinout vyšetřovací protokol umožňující zobrazení funkční integrity a mikrostrukturálního postižení periferních nervů (PN) v různých lokalitách pomocí difuzního tenzoru (DTI). Následně implementovat vyšetřovací protokol do klinické praxe. Soubor a metodika: Vyšetřili jsme 15 zdravých dobrovolníků a 15 pacientů na 3T MR přístroji pomocí metody DTI. Snažili jsme se zobrazit brachiální plexus, lumbosakrální plexus a průběh PN na končetinách u zdravých dobrovolníků. U pacientů jsme cílili vyšetření na postižené úseky PN za účelem zobrazit tyto patologie. Výsledky: Podařilo se nám získat validní zobrazení brachiálního i lumbosakrálního plexu a průběhu PN na končetinách pomocí DTI. Setkali jsme se s některými limitacemi metody, zejména pohybovými artefakty, narušujícími kvalitní zobrazení nervových struktur, a problémy s odlišením nervových vláken od vláken svalových. Tyto technické problémy mohou být do určité míry eliminovány využitím adekvátních cívek, optimalizací zobrazovacích protokolů a metodikou následného zpracování dat. Závěr: Přes některé technické limitace práce demonstruje možnost získat validní zobrazení PN v různých lokalitách prostřednictvím metody DTI. DTI představuje doplňkovou neinvazivní zobrazovací techniku poskytující cenné informace využitelné v rozhodovacím diagnostickém a léčebném procesu u nejrůznějších patologií PN. Technologický pokrok a další zdokonalování metod MR v budoucnu pravděpodobně povede k rozšíření a širšímu uplatnění této techniky v klinické praxi.
Aim: Development of an examination protocol for investigation of functional integrity and microstructural damage of peripheral nerves (PN) at different locations using diffusion tensor imaging (DTI). Consequently, we want to implement this protocol into clinical practice. Subjects and methods: We investigated 15 healthy volunteers and 15 patients with a 3T MRI, scanner using the DTI method. We attempted to visualize the brachial plexus, lumbosacral plexus and the course of PN in the limbs of healthy volunteers. In patients, we focused on the examination of damaged parts of the PN to display these pathologies. Results: We managed to obtain a valid visualization of the brachial plexus, lumbosacral plexus and the course of PN in the limbs using DTI. Throughout the study, we encountered some limitations of this method, particularly motion artifacts which interfered with the quality of nerve structure imaging and problems in differentiating nerve fibers from muscle fibers. These technical problems could be reduced to a certain extent using adequate coils, optimizing imaging protocols and data procesing methodology. Conclusion: Despite some technical limitations, this paper demonstrates the possibility of obtaining a valid display of PN in different locations using the DTI method. DTI is an additional non-invasive imaging technique providing valuable information useful in the decision-making diagnostic and therapeutic process for various PN pathologies. Technological advances and further improvements of MRI techniques in the future are likely to result in a wider use of this technique in clinical practice.
- MeSH
- dospělí MeSH
- klinická studie jako téma MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetická rezonanční tomografie * metody MeSH
- mladý dospělý MeSH
- periferní nervy * diagnostické zobrazování MeSH
- plexus brachialis diagnostické zobrazování MeSH
- plexus lumbosacralis diagnostické zobrazování MeSH
- zobrazování difuzních tenzorů * metody MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- práce podpořená grantem MeSH
Cíl: Uvést naše zkušenosti s downstagingem hepatocelulárního karcinomu (HCC) u pacientů původně překračujících obecně uznávaná kritéria pro transplantaci jater. Metoda. V letech 2013-2017 bylo 13 pacientů s HCC překračujícím milánská i UCSF kritéria k transplantaci léčeno transarteriální chemoembolizací s cílem downstagingu. U všech nemocných byla provedena drug-eluting bead superselektivní chemoembolizace, do přívodně tepny tumoru byly aplikovány částice DC bead 100-300 μm s navázaným doxorubicinem. Výsledky: Downstaging byl úspěšný u všech nemocných. Odpověď nádoru na embolizaci byla hodnocena dle modifikovaných RECIST kritérií na CT, všichni pacienti splňovali Milánská kritéria a byli zařazeni na čekací listinu k transplantaci. Deset nemocných bylo úspěšně transplantováno. Závěr: Drug-eluting bead TÁCE je vhodnou metodou pro dosažení úspěšného downstagingu do Milánských kritérií u vybraných pacientů.
Aim: Presentation of our experience with downstaging of hepatocellular carcinoma (HCC) in patients originally exceeding current liver transplant criteria. Method: Between 2013 and 2017 thirteen patients with HCC exceeding Milan and UCSF liver transplant criteria were treated by transarterial chemoembolization (TACE) as downstaging method. Superselective embolization with drug-eluting beads was performed in all patients, doxorubicin loaded DC beads 100-300 μm were applied to tumor feeding artery. Results: Downstaging was successful in all patients. Tumor response to embolization was evaluated by modified RECIST criteria on CT, all patients met Milan criteria and joined the waiting list for transplantation. Ten patients were successfully transplanted. Conclusion: Drug-eluting bead TACE is acceptable method to achieve successfull downstaging of HCC to Milan criteria in selected patients.
- MeSH
- chemoembolizace * metody MeSH
- doxorubicin aplikace a dávkování MeSH
- hepatocelulární karcinom diagnostické zobrazování farmakoterapie patologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- neoadjuvantní terapie metody MeSH
- stupeň nádoru MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
Cíl: Ověřit, zda je u pacientů v časném stadiu onemocnění schizofrenií přítomno poškození mikrostruktury bílé hmoty mozkové. Metodika: V prospektivní studii byla pomocí magnetické rezonance zkoumána frakční anizotropie (FA) bílé hmoty mozkové u souboru nemocných po první epizodě schizofrenie (n = 23) a kontrolního souboru zdravých jedinců (n = 23). Hodnoty frakční anizotropie získané z multidirekcionálně difuzně vážené sekvence byly analyzovány prostřednictvím Tract-Based Spatial Statistics (TBSS). Výsledky: U nemocných po první epizodě schizofrenie byly nalezeny rozsáhlé oblasti poklesu FA bílé hmoty mozkové lokalizované disperzně v celém vyšetřeném objemu mozku, postihující většinu diferencovatelných traktů. Nebyly prokázány statisticky významné oblasti vzestupu FA oproti kontrolní skupině. Závěr: Již při první epizodě schizofrenie jsou přítomny mikrostrukturální změny v rozsáhlých oblastech bílé hmoty mozkové.
Purpose: To assess microstructural changes of the cerebral white matter in the earliest stage of schizophrenia. Methods: Magnetic resonance was used to prospectively compare fractional anisotropy of the white matter between subjects after the first episode of schizophrenia (n = 23) and healthy controls (n = 23). Diffusion tensor data obtained from multidirectional diffusion weighted sequence were analysed by using Tract-Based Spatial Statistics (TBSS). Results: Extensive areas of decreased fractional anisotropy (FA) were found in the white matter after the first episode of schizophrenia, affecting most of the white matter tracts. No areas of significantly increased FA were found when compared to the healthy control group. Conclusion: Extensive areas of micro-structural alteration of the white matter are already present during the first episode of schizophrenia.
Prvotní zobrazení srdce magnetickou rezonancí (cardiac magnetic resonance imaging - CMR) trpělo špatnou kvalitou obrazu, tedy nedosahovalo požadované úrovně kvality. K velkému zlepšení došlo zavedením segmentované akvizice dat k-prostoru spolu se synchronizací akvizice s EKG pacienta, ať už při zadrženém dechu, nebo při volném dýchání s dechovým navigátorem. V současné době se CMR používá nejčastěji pro hodnocení srdeční funkce, charakterizaci tkání, hodnocení zánětlivých nebo post-in-farktových změn a také pro hodnocení střádavých onemocnění, kde své uplatnění nachází pozdně postkontrastní skeny (tzv. late gadolinium enhancement - LGE). Své uplatnění však CMR nachází také při hodnocení chlopní, kdy je možné provádět i měření průtoku danou oblastí, nebo u hodnocení srdečních dysynchronií. Mimo získaná onemocnění se využívá i u pacientů s vrozenými vadami srdce, kde umožňuje objektivně sledovat dlouhodobý vývoj nemoci.
Early cardiac magnetic resonance imaging (CMR) scans were of inferior quality. A significant improvement in image quality was achieved after introducing the segmented acquisition of the k-space synchronized with patients ECG, performed either in breath hold or free breathing. CMR is now used widely in the clinical setting for assessment of cardiac chamber volumes, global and regional cardiac contraction, morphology and tissue characterization. Inflammatory or post-myocardial infarction changes involve sequences which can appreciate myocardial edema or the use of late post-gadolinium contrast enhancement (LGE) to visualise diffuse or focal scar. Other applications include the assessment of valvular stenosis or regurgitation by means of flow measurement through a defined orifice and first pass myocardial perfusion to assess ischemia. Last but not least, CMR is increasingly used for the assessment of congenital heart diseases, in which CMR offers objective and directly comparable measures during serial examinations, without any radiation exposure.