Poly(ɛ-caprolactone) (PCL) is a biocompatible, biodegradable, and highly mechanically resilient FDA-approved material (for specific biomedical applications, e.g. as drug delivery devices, in sutures, or as an adhesion barrier), rendering it a promising candidate to serve bone tissue engineering. However, in vivo monitoring of PCL-based implants, as well as biodegradable implants in general, and their degradation profiles pose a significant challenge, hindering further development in the tissue engineering field and subsequent clinical adoption. To address this, photo-cross-linkable mechanically resilient PCL networks are developed and functionalized with a radiopaque monomer, 5-acrylamido-2,4,6-triiodoisophthalic acid (AATIPA), to enable non-destructive in vivo monitoring of PCL-based implants. The covalent incorporation of AATIPA into the crosslinked PCL networks does not significantly affect their crosslinking kinetics, mechanical properties, or thermal properties, but it increases their hydrolysis rate and radiopacity. Complex and porous 3D designs of radiopaque PCL networks can be effectively monitored in vivo. This work paves the way toward non-invasive monitoring of in vivo degradation profiles and early detection of potential implant malfunctions.
- Klíčová slova
- computed tomography contrast agent, implant, light‐based 3D printing, light‐based crosslinking, photo‐crosslinkable polymers, polyester, thiol‐ene step growth polymerization,
- MeSH
- biokompatibilní materiály chemie MeSH
- myši MeSH
- polyestery * chemie MeSH
- poréznost MeSH
- testování materiálů MeSH
- tkáňové inženýrství metody MeSH
- tkáňové podpůrné struktury * chemie MeSH
- vstřebatelné implantáty MeSH
- zvířata MeSH
- Check Tag
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- biokompatibilní materiály MeSH
- polycaprolactone MeSH Prohlížeč
- polyestery * MeSH
Gelatin-based photo-crosslinkable hydrogels are promising scaffold materials to serve regenerative medicine. They are widely applicable in additive manufacturing, which allows for the production of various scaffold microarchitectures in line with the anatomical requirements of the organ to be replaced or tissue defect to be treated. Upon their in vivo utilization, the main bottleneck is to monitor cell colonization along with their degradation (rate). In order to enable non-invasive visualization, labeling with MRI-active components like N-(2,2-difluoroethyl)acrylamide (DFEA) provides a promising approach. Herein, we report on the development of a gelatin-methacryloyl-aminoethyl-methacrylate-based biomaterial ink in combination with DFEA, applicable in digital light processing-based additive manufacturing towards bone tissue regeneration. The fabricated hydrogel constructs show excellent shape fidelity in line with the printing resolution, as DFEA acts as a small molecular crosslinker in the system. The constructs exhibit high stiffness (E = 36.9 ± 4.1 kPa, evaluated via oscillatory rheology), suitable to serve bone regeneration and excellent MRI visualization capacity. Moreover, in combination with adipose tissue-derived stem cells (ASCs), the 3D-printed constructs show biocompatibility, and upon 4 weeks of culture, the ASCs express the osteogenic differentiation marker Ca2+.
Aqueous solutions of some polymers exhibit a lower critical solution temperature (LCST); that is, they form phase-separated aggregates when heated above a threshold temperature. Such polymers found many promising (bio)medical applications, including in situ thermogelling with controlled drug release, polymer-supported radiotherapy (brachytherapy), immunotherapy, and wound dressing, among others. Yet, despite the extensive research on medicinal applications of thermoresponsive polymers, their biodistribution and fate after administration remained unknown. Thus, herein, they studied the pharmacokinetics of four different thermoresponsive polyacrylamides after intramuscular administration in mice. In vivo, these thermoresponsive polymers formed depots that subsequently dissolved with a two-phase kinetics (depot maturation, slow redissolution) with half-lives 2 weeks to 5 months, as depot vitrification prolonged their half-lives. Additionally, the decrease of TCP of a polymer solution increased the density of the intramuscular depot. Moreover, they detected secondary polymer depots in the kidneys and liver; these secondary depots also followed two-phase kinetics (depot maturation and slow dissolution), with half-lives 8 to 38 days (kidneys) and 15 to 22 days (liver). Overall, these findings may be used to tailor the properties of thermoresponsive polymers to meet the demands of their medicinal applications. Their methods may become a benchmark for future studies of polymer biodistribution.
- Klíčová slova
- LCST, biodistribution, poly(2,2-difluoroethyl)acrylamide, poly(N,N-diethylacrylamide), poly(N-acryloylpyrolidine), poly(N-isopropylacrylamide), polyacrylamide, rational polymer design,
- MeSH
- myši MeSH
- polymery * MeSH
- teplota MeSH
- tkáňová distribuce MeSH
- uvolňování léčiv MeSH
- voda * MeSH
- zvířata MeSH
- Check Tag
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- polymery * MeSH
- voda * MeSH
Stem cells are characterized by their self-renewal capacity and their ability to differentiate into multiple cell types of the human body. Using directed differentiation strategies, stem cells can now be converted into hepatocyte-like cells (HLCs) and therefore, represent a unique cell source for toxicological applications in vitro. However, the acquired hepatic functionality of stem cell-derived HLCs is still significantly inferior to primary human hepatocytes. One of the main reasons for this is that most in vitro models use traditional two-dimensional (2D) setups where the flat substrata cannot properly mimic the physiology of the human liver. Therefore, 2D-setups are progressively being replaced by more advanced culture systems, which attempt to replicate the natural liver microenvironment, in which stem cells can better differentiate towards HLCs. This review highlights the most recent cell culture systems, including scaffold-free and scaffold-based three-dimensional (3D) technologies and microfluidics that can be employed for culture and hepatic differentiation of stem cells intended for hepatotoxicity testing. These methodologies have shown to improve in vitro liver cell functionality according to the in vivo liver physiology and allow to establish stem cell-based hepatic in vitro platforms for the accurate evaluation of xenobiotics.
- Klíčová slova
- 2D- and 3D-culture systems, Drug screening, Hepatocyte-like cells, In vitro toxicity, Microfluidics, Stem cells,
- MeSH
- alternativy testů na zvířatech metody MeSH
- buněčná diferenciace účinky léků MeSH
- buněčné kultury MeSH
- hepatocyty cytologie účinky léků MeSH
- játra účinky léků MeSH
- kmenové buňky cytologie účinky léků MeSH
- lékové postižení jater etiologie MeSH
- lidé MeSH
- xenobiotika toxicita MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Názvy látek
- xenobiotika MeSH
Immunocompatibility of gelatin-based hydrogels to be applied as implant coatings for local regenerative treatment has been studied. First, the bio- and immuno-acceptability of the methacrylamide-modified gelatin hydrogels per se was screened. The results indicated that the hydrogels support cell growth. Metabolic activity of normal cells and permanent cell lines representing various cell types (endothelial, epithelial, fibroblast, and monocyte/macrophage) cultivated on the gelatin hydrogels was moderately lower compared to cells cultivated on tissue culture plastic. The cells cultivated on the hydrogels produced identical cytokines as the control cells although at lower levels. Importantly, no inflammatory activity, measured by nitric oxide and pro-inflammatory cytokine (IL-1α, IL-6, and TNFα) production, was observed in peritoneal cells and monocyte/macrophage RAW 264.7 cell line cultivated on the hydrogels. Finally, polyimide (PI) implantable membranes were surface-modified with gelatin hydrogels and screened for their in vivo immunocompatibility. Their histological examination performed after subcutaneous implantation in mice produced a sound proof of immunoacceptability. Normal tissue repair, mild cellular infiltration and edema mainly induced by the surgery were observed after 2 and 6 days. No adverse tissue responses were induced by the implants. Analysis performed after 4 and 9 weeks indicated areas of foreign body granuloma without formation of a fibrous capsule.
- Klíčová slova
- hydrogel, immunocompatibility, methacrylamide-modified gelatin, polyimide implant, subcutaneous implantation,
- MeSH
- akrylamidy chemie imunologie MeSH
- biokompatibilní materiály chemie metabolismus MeSH
- buněčné linie MeSH
- cytokiny imunologie MeSH
- fibroblasty cytologie imunologie MeSH
- hydrogely chemie metabolismus MeSH
- lidé MeSH
- makrofágy cytologie imunologie MeSH
- myši inbrední BALB C MeSH
- myši MeSH
- proliferace buněk MeSH
- protézy a implantáty MeSH
- regenerativní lékařství MeSH
- želatina chemie imunologie MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- akrylamidy MeSH
- biokompatibilní materiály MeSH
- cytokiny MeSH
- hydrogely MeSH
- methacrylamide MeSH Prohlížeč
- želatina MeSH