Purpose. The purpose of this study was to evaluate the technical and diagnostic performance of sub-milliSievert ultralow-dose (ULD) CT colonograpy (CTC) in the detection of colonic and extracolonic lesions. Materials and Methods. CTC with standard dose (SD) and ULD acquisitions of 64 matched patients, half of them with colonic findings, were reconstructed with filtered back projection (FBP), hybrid (HIR) and iterative model reconstruction techniques (IMR). Image noise in six colonic segments, in the left psoas muscle and aorta were measured. Image quality of the left adrenal gland and of the colon in the endoscopic and 2D view was rated on a five point Likert scale by two observers, who also completed the reading of CTC for colonic and extracolonic findings. Results. The mean radiation dose estimate was 4.1 ± 1.4 mSv for SD and 0.86 ± 0.17 mSv for ULD for both positions (p < 0.0001). In ULD-IMR, SD-IMR and SD-HIR, the endoluminal noise was decreased in all colonic segments compared to SD-FBP (p < 0.001). There were 27 small (6-9 mm) and 17 large (≥10 mm) colonic lesions that were classified as sessile polyps (n = 38), flat lesions (n = 3), or as a mass (n = 3). Per patient sensitivity and specificity were 0.82 and 0.93 for ULD-FBP, 0.97 and 0.97 for ULD-HIR, 0.97 and 1.0 for ULD-IMR. Per polyp sensitivity was 0.84 for ULD-FBP, 0.98 for ULD-HIR, 0.98 for ULD-IMR. Significantly less extracolonic findings were detected in ULD-FBP and ULD-HIR, but in the E4 category by C-RADS (potentially important findings), the detection was similar. Conclusion. Both HIR and IMR are suitable for sub-milliSievert ULD CTC without sacrificing diagnostic performance of the study.
- Klíčová slova
- CT colonography, Iterative reconstruction technique, Low-dose, Polyp,
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Computed tomography (CT) colonography is a well established modality for the examination of symptomatic patients as well as in screening. Recent technical advances in improving image quality by iterative reconstruction contribute to the reduction of the radiation dose which is a major concern in CT imaging. PURPOSE: To evaluate image quality of ultralow-dose submilisievert CT colonography using hybrid iterative reconstruction technique. MATERIAL AND METHODS: Sixteen patients underwent contrast-enhanced CT colonography with standard protocol in supine position and ultralow-dose protocol in prone position. Ultralow-dose datasets were reconstructed with filtered back projection and an advanced hybrid iterative reconstruction technique. Two radiologists independently evaluated 96 colonic segments for image quality in the endoluminal view and axial thin sections. Colonic distension, smoothness of colonic wall and distortion of folds in the endoluminal view, sharpness of colonic wall delineation, perceived image noise, and presence of photon starvation artifact were rated on a five-point scale. Intraluminal noise expressed as standard deviation of Hounsfield density was measured in all segments. RESULTS: The mean radiation dose was 0.42 mSv and 5.48 mSv in prone and supine scans, respectively. All distended segments were rated evaluable in standard dose and ultralow-dose series reconstructed with the iterative reconstruction technique, whereas in 61% segments image quality was rated poor or unacceptable in ultralow-dose series where filtered back projection was used with worst ratings in the rectum and the sigmoid colon. CONCLUSION: This pilot study shows that iterative reconstruction technique is a feasible method to decrease the radiation dose from CT colonography for both positions below 1mSv. Further investigations of larger scale need to be done to clarify, whether such a low radiation dose would influence the detection of polyps.
- Klíčová slova
- Colonography, colon, computed tomography, iterative reconstruction, low-dose, polyp,
- MeSH
- dávka záření * MeSH
- kolonografie počítačovou tomografií metody MeSH
- kontrastní látky MeSH
- kyseliny trijodbenzoové MeSH
- lidé MeSH
- nemoci střev diagnostické zobrazování MeSH
- pilotní projekty MeSH
- rentgenový obraz - interpretace počítačová metody MeSH
- senioři MeSH
- studie proveditelnosti MeSH
- vylepšení rentgenového snímku metody MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- ioversol MeSH Prohlížeč
- kontrastní látky MeSH
- kyseliny trijodbenzoové MeSH
OBJECTIVE: To compare image quality of different reconstruction techniques in submillisievert ultralow-dose CT colonography (CTC) and to correlate colonic findings with subsequent optical colonoscopy. METHODS: 58 patients underwent ultralow-dose CTC. The images were reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR) or model-based iterative reconstruction (MBIR) techniques. In each segment, endoluminal noise (expressed as standard deviation of endoluminal density) was measured and image quality was rated on a five-point Likert scale by two independent readers. Colonic lesions were evaluated in consensus and correlated with subsequent optical colonoscopy where possible. RESULTS: The estimated radiation dose was 0.41 ± 0.05 mSv for the supine and 0.42 ± 0.04 mSv for the prone acquisitions. In the endoluminal view, the image quality was rated better in HIR, whereas better scores were obtained in MBIR in the cross-sectional view, where the endoluminal noise was the lowest (p < 0.0001). Five (26%) polyps were not identified using both computer-aided detection and endoluminal inspection in FBP images vs only one (5%) in MBIR and none in HIR images. CONCLUSION: This study showed that in submillisievert ultralow-dose CTC, the image quality for the endoluminal view is better when HIR is used, whereas MBIR yields superior images for the cross-sectional view. The inferior quality of images reconstructed with FBP may result in decreased detection of colonic lesions. ADVANCES IN KNOWLEDGE: Radiation dose from CTC can be safely reduced <1 mSv for both positions when iterative reconstruction is used. MBIR provides better image quality in the cross-sectional view and HIR in the endoluminal view.
- MeSH
- dávka záření MeSH
- kolonografie počítačovou tomografií metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- rentgenový obraz - interpretace počítačová metody MeSH
- senioři MeSH
- teoretické modely MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
AIMS: To compare the image characteristics, effective dose and estimated organ dose to the female breast in pulmonary MDCT angiography (MDCTA), reconstructed with either standard filtered back projection (FBP), or iterative reconstruction in image space (IRIS). METHODS: Pulmonary MDCTA performed in 116 females (age 18 - 77 years; body mass index 15 - 48) was reconstructed with FBP (n=52) or IRIS (n=64). Scans were acquired on a 128-row MDCT system using automatic tube current modulation, 100 kV tube voltage, and a quality reference mAs value of 120 (FBP) and 80 (IRIS). Dose was calculated from CT dose index (CTDIvol) and dose length product (DLP) values utilising ImPACT software. Image noise was measured within the pulmonary artery. Qualitative visual assessment of the scans was performed (1=negligible noise, 5=noise obscuring diagnostic information). RESULTS: The average CTDIvol yielded 4.33 mGy for FBP and 3.54 mGy for IRIS, respectively (18.2% decrease). The average effective scan dose was 2.73±0.57 mSv (FBP) and 2.29±0.68 mSv (IRIS), respectively (16.1% decrease). The estimated average organ dose to the breast decreased from 5.1±1.1 mGy (FBP) to 4.2±1.2 mGy (IRIS, 17.6% decrease). No non-diagnostic scans (score 5) were encountered in either group. Significant improvement in image noise levels (P<0.01) and subjective image quality (P<0.02) were noted in IRIS group. CONCLUSION: Pulmonary MDCTA utilizing a 100 kV technique, automatic tube current modulation, and iterative image reconstruction offers robust results in routine conditions among an unselected female population, with breast doses being comparable to two-view digital mammography. Moreover, iterative reconstruction offers improvements in both image noise and visual perception of the scans, thus suggesting a potential for further dose reduction.
- MeSH
- angiografie metody MeSH
- dávka záření MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- multidetektorová počítačová tomografie metody MeSH
- plicní embolie diagnostické zobrazování MeSH
- počítačové zpracování obrazu metody MeSH
- poměr signál - šum MeSH
- prospektivní studie MeSH
- prsy MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
- srovnávací studie MeSH
We report three-dimensional spin noise imaging (SNI) of nuclear spin density from spin noise data acquired by Faraday detection. Our approach substantially extends and improves the two-dimensional SNI method for excitation-less magnetic resonance tomography reported earlier (Müller and Jerschow, 2006). This proof of principle was achieved by taking advantage of the particular continuous nature of spin noise acquired in the presence of constant magnitude magnetic field gradients and recent advances in nuclear spin noise spectroscopy acquisition as well as novel processing techniques. In this type of projection-reconstruction-based spin noise imaging the trade-off between signal-to-noise ratio (or image contrast) and resolution can be adjusted a posteriori during processing of the original time-domain data by iterative image reconstruction in a unique way not possible in conventional rf-pulse-dependent magnetic resonance imaging (MRI). The 3D SNI is demonstrated as a proof of concept on a commercial 700 MHz high-resolution NMR spectrometer, using a 3D-printed polymeric phantom immersed in water.
- Publikační typ
- časopisecké články MeSH
AIMS: To compare the effective and eye lens radiation dose in helical MDCT brain examinations using automatic tube current modulation in conjunction with either standard filtered back projection (FBP) technique or iterative reconstruction in image space (IRIS). METHODS: Of 400 adult brain MDCT examinations, 200 were performed using FBP and 200 using IRIS with the following parameters: tube voltage 120 kV, rotation period 1 second, pitch factor 0.55, automatic tube current modulation in both transverse and longitudinal planes with reference mAs 300 (FBP) and 200 (IRIS). Doses were calculated from CT dose index and dose length product values utilising ImPACT software; the organ dose to the lens was derived from the actual tube current-time product value applied to the lens. Image quality was assessed by two independent readers blinded to the type of image reconstruction technique. RESULTS: The average effective scan dose was 1.47±0.26 mSv (FBP) and 0.98±0.15 mSv (IRIS), respectively (33.3% decrease). The average organ dose to the eye lens decreased from 40.0±3.3 mGy (FBP) to 26.6±2.0 mGy (IRIS, 33.5% decrease). No significant change in diagnostic image quality was noted between IRIS and FBP scans (P=0.17). CONCLUSION: Iterative reconstruction of cerebral MDCT examinations enables reduction of both effective and organ eye lens dose by one third without signficant loss of image quality.
- MeSH
- dávka záření MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mozek diagnostické zobrazování MeSH
- multidetektorová počítačová tomografie metody MeSH
- oční čočka * MeSH
- počítačové zpracování obrazu metody MeSH
- poměr signál - šum MeSH
- prospektivní studie MeSH
- senioři nad 80 let MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVE: The aim of this study was to compare three different reconstruction algorithms for the volumetry of the visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) on ultra-low-dose computed tomography (CT) images. METHODS: Thirty-seven male patients underwent ultra-low-dose CT at the level of the fourth lumbar vertebra (22.5 mm in z-axis). The acquisitions were reconstructed in 5-mm slices with 50% overlap using filtered back projection (FBP), hybrid iterative reconstruction (HIR), and iterative model-based reconstruction (IMR) techniques. The volume of VAT and SAT was measured using an interactive seed-growing segmentation and by thresholding (-30 to -190 HU). RESULTS: The volume of SAT measured by the interactive method was smaller in FBP compared with both HIR (P = 0.0011) and IMR (P = 0.0034), and the volume of VAT was greater in IMR compared with HIR (P = 0.0253) or FBP (P = 0.0065). Using the thresholding method, IMR volumes of VAT were greater compared with HIR (P < 0.0001), and volumes of SAT were greater compared with both HIR and FBP (both P ≤ 0.0001). The VAT to SAT ratio was greater in IMR compared with HIR or FBP (both P < 0.0001). CONCLUSIONS: There are significant differences among FBP, HIR, and IMR in the volumetry of SAT and VAT, their ratios, and attenuation measured on ultra-low-dose images.
Cryo Electron Tomography (cryoET) plays an essential role in Structural Biology, as it is the only technique that allows to study the structure of large macromolecular complexes in their close to native environment in situ. The reconstruction methods currently in use, such as Weighted Back Projection (WBP) or Simultaneous Iterative Reconstruction Technique (SIRT), deliver noisy and low-contrast reconstructions, which complicates the application of high-resolution protocols, such as Subtomogram Averaging (SA). We propose a Progressive Stochastic Reconstruction Technique (PSRT) - a novel iterative approach to tomographic reconstruction in cryoET based on Monte Carlo random walks guided by Metropolis-Hastings sampling strategy. We design a progressive reconstruction scheme to suit the conditions present in cryoET and apply it successfully to reconstructions of macromolecular complexes from both synthetic and experimental datasets. We show how to integrate PSRT into SA, where it provides an elegant solution to the region-of-interest problem and delivers high-contrast reconstructions that significantly improve template-based localization without any loss of high-resolution structural information. Furthermore, the locality of SA is exploited to design an importance sampling scheme which significantly speeds up the otherwise slow Monte Carlo approach. Finally, we design a new memory efficient solution for the specimen-level interior problem of cryoET, removing all associated artifacts.
- Klíčová slova
- 3D reconstruction, Cryo electron tomography, Metropolis–Hastings, Monte Carlo, Stochastic reconstruction, Subtomogram averaging,
- MeSH
- algoritmy MeSH
- elektronová kryomikroskopie metody MeSH
- makromolekulární látky chemie MeSH
- metoda Monte Carlo MeSH
- počítačové zpracování obrazu metody MeSH
- reprodukovatelnost výsledků MeSH
- ribozomy chemie MeSH
- stochastické procesy * MeSH
- tomografie elektronová metody MeSH
- zobrazování trojrozměrné metody MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- makromolekulární látky MeSH
The purpose of this paper is to employ an alternative approach to reconstruct the standard variational iteration algorithm II proposed by He, including Lagrange multiplier, and to give a simpler formulation of Adomian decomposition and modified Adomian decomposition method in terms of newly proposed variational iteration method-II (VIM). Through careful investigation of the earlier variational iteration algorithm and Adomian decomposition method, we find unnecessary calculations for Lagrange multiplier and also repeated calculations involved in each iteration, respectively. Several examples are given to verify the reliability and efficiency of the method.
- MeSH
- algoritmy MeSH
- matematika * MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
INTRODUCTION: The aim of this study was to determine the optimal image matrix and half-width of the Gaussian filter after iterative reconstruction of the PET image with point-spread function (PSF) and time-of-flight (TOF) correction, based on measuring the recovery coefficient (RC) curves. The measured RC curves were compared to those from an older system which does not use PSF and TOF corrections. MATERIALS AND METHODS: The measurements were carried out on a NEMA IEC Body Phantom. We measured the RC curves based on SUVmax and SUVA50 in source spheres with different diameters. The change in noise level for different reconstruction parameter settings and the relation between RC curves and the administered activity were also evaluated. RESULTS: With an increasing size of image matrix and reduction in the half-width of the post-reconstruction Gaussian filter, there was a significant increase in image noise and overestimation of the SUV. The local increase in SUV, observed for certain filtrations and objects with a diameter below 13mm, was caused by PSF correction. The decrease in administered activity, while maintaining the same conditions of acquisition and reconstruction, also led to overestimation of readings of the SUV and additionally to deterioration in reproducibility. CONCLUSION: This study proposes a suitable size for the image matrix and filtering for displaying PET and SUV measurements. The benefits were demonstrated as improved image parameters for the newer instrument, these even being found using relatively strong filtration of the reconstructed images.
- MeSH
- fantomy radiodiagnostické * MeSH
- lidé MeSH
- počítačové zpracování obrazu * MeSH
- pozitronová emisní tomografie * MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH