-
Something wrong with this record ?
New method for the determination of carbamate and pyrethroid insecticides in water samples using on-line SPE fused core column chromatography
C. Fernández-Ramos, D. Satínský, P. Solich,
Language English Country Netherlands
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Water Pollutants, Chemical analysis MeSH
- Chromatography, Liquid MeSH
- Solid Phase Extraction methods MeSH
- Insecticides analysis MeSH
- Lakes MeSH
- Carbamates analysis MeSH
- Environmental Monitoring methods MeSH
- Online Systems MeSH
- Organic Chemicals analysis MeSH
- Pyrethrins analysis MeSH
- Rivers MeSH
- Reproducibility of Results MeSH
- Spectrophotometry, Ultraviolet MeSH
- Water chemistry MeSH
- Chromatography, High Pressure Liquid methods MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Geographicals
- Czech Republic MeSH
A new HPLC column-switching method using large volume sample injection and fused-core columns for on-line solid phase extraction have been developed for the determination of the following carbamates and pyrethroids: aldicarb, carbaryl, pirimicarb, carbofuran, kadethrin, flumethrin, fenpropathrin, fenoxycarb, tau-fluvalinate and fenvalerate, in surface water samples. Sudan I was used as internal standard. The proposed method was performed using 100 µl sample injection followed by an on-line solid phase extraction procedure and finally the compounds were identified and quantified by liquid chromatography with ultraviolet detection. The separation was carried out on C-18 reversed phase column based on fused-core particle technology. The influence of the injected sample volume, the variables affecting to SPE process and the conditions for the separation on an analytical column, were studied and optimized. The limits of detection ranged from 5.5 to 8.9 µg L(-1), and limits of quantification from 18.4 to 29.7 µg L(-1), while inter- and intra-day variability was under 15%. This new analytical procedure was satisfactorily applied for the determination of these organic pollutants in surface water samples located in Czech Republic. Concentration levels were found for some of these pollutants up to 26.11 µg L(-1) in the river Elbe and up to 34.53 µg L(-1) in the closed lakes samples.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15023126
- 003
- CZ-PrNML
- 005
- 20150709122420.0
- 007
- ta
- 008
- 150709s2014 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2014.06.037 $2 doi
- 035 __
- $a (PubMed)25127636
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Fernández-Ramos, C $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského1203, 500 05 Hradec Králové, Czech Republic.
- 245 10
- $a New method for the determination of carbamate and pyrethroid insecticides in water samples using on-line SPE fused core column chromatography / $c C. Fernández-Ramos, D. Satínský, P. Solich,
- 520 9_
- $a A new HPLC column-switching method using large volume sample injection and fused-core columns for on-line solid phase extraction have been developed for the determination of the following carbamates and pyrethroids: aldicarb, carbaryl, pirimicarb, carbofuran, kadethrin, flumethrin, fenpropathrin, fenoxycarb, tau-fluvalinate and fenvalerate, in surface water samples. Sudan I was used as internal standard. The proposed method was performed using 100 µl sample injection followed by an on-line solid phase extraction procedure and finally the compounds were identified and quantified by liquid chromatography with ultraviolet detection. The separation was carried out on C-18 reversed phase column based on fused-core particle technology. The influence of the injected sample volume, the variables affecting to SPE process and the conditions for the separation on an analytical column, were studied and optimized. The limits of detection ranged from 5.5 to 8.9 µg L(-1), and limits of quantification from 18.4 to 29.7 µg L(-1), while inter- and intra-day variability was under 15%. This new analytical procedure was satisfactorily applied for the determination of these organic pollutants in surface water samples located in Czech Republic. Concentration levels were found for some of these pollutants up to 26.11 µg L(-1) in the river Elbe and up to 34.53 µg L(-1) in the closed lakes samples.
- 650 _2
- $a karbamáty $x analýza $7 D002219
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
- 650 _2
- $a chromatografie kapalinová $7 D002853
- 650 _2
- $a monitorování životního prostředí $x metody $7 D004784
- 650 _2
- $a insekticidy $x analýza $7 D007306
- 650 _2
- $a jezera $7 D060106
- 650 _2
- $a on-line systémy $7 D009862
- 650 _2
- $a organické látky $x analýza $7 D009930
- 650 _2
- $a pyrethriny $x analýza $7 D011722
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a řeky $7 D045483
- 650 _2
- $a extrakce na pevné fázi $x metody $7 D052616
- 650 _2
- $a spektrofotometrie ultrafialová $7 D013056
- 650 _2
- $a voda $x chemie $7 D014867
- 650 _2
- $a chemické látky znečišťující vodu $x analýza $7 D014874
- 651 _2
- $a Česká republika $7 D018153
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Satínský, D $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského1203, 500 05 Hradec Králové, Czech Republic. Electronic address: satinsky@faf.cuni.cz.
- 700 1_
- $a Solich, P $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského1203, 500 05 Hradec Králové, Czech Republic.
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 129, č. - (2014), s. 579-85
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25127636 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150709 $b ABA008
- 991 __
- $a 20150709122440 $b ABA008
- 999 __
- $a ok $b bmc $g 1083464 $s 906119
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 129 $c - $d 579-85 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20150709