Something wrong with this record ?
Biodegradable tracheal stents: our ten-year experience with adult patients
L. Stehlik, D. Guha, S. Anandakumar, A. Taskova, MK. Vasakova
Language English Country England, Great Britain
Document type Journal Article
NLK
BioMedCentral
from 2001-12-01
BioMedCentral Open Access
from 2001
Directory of Open Access Journals
from 2001
Free Medical Journals
from 2001
PubMed Central
from 2001
Europe PubMed Central
from 2001
ProQuest Central
from 2009-01-01
Open Access Digital Library
from 2001-01-01
Open Access Digital Library
from 2001-09-01
Open Access Digital Library
from 2001-01-01
Medline Complete (EBSCOhost)
from 2001-01-01
Health & Medicine (ProQuest)
from 2009-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2001
Springer Nature OA/Free Journals
from 2001-12-01
- MeSH
- Bronchoscopy * MeSH
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Young Adult MeSH
- Polydioxanone MeSH
- Prosthesis Design MeSH
- Retrospective Studies MeSH
- Aged MeSH
- Tracheal Stenosis * surgery MeSH
- Stents * MeSH
- Trachea surgery MeSH
- Tracheomalacia surgery MeSH
- Absorbable Implants * MeSH
- Treatment Outcome MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Young Adult MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Geographicals
- Czech Republic MeSH
BACKGROUND: Biodegradable (BD) stents made from polydioxanone have been used only in human airways. These stents combine the advantages of classical tracheal stents, and fewer side effects are expected due to their biocompatibility and their time-limited presence in airways. However, new clinical consequences have arisen. Here, the authors share their experiences with BD stents for tracheal indications, focusing on their safety and efficacy. METHODS: This was a retrospective review of a collected database of adult patients who underwent implantation of biodegradable tracheal stents between September 2013 and December 2022 at the Department of Respiratory Medicine of the 1st Faculty of Medicine in Prague and Thomayer University Hospital. The indications included functionally significant nonmalignant tracheal stenosis and tracheomalacia. Self-expandable, biodegradable, polydioxanone tracheal stents manufactured by ELLA-CS Ltd. (Hradec Kralove, Czech Republic) were implanted during rigid bronchoscopy under general anaesthesia. All patients were followed up in the department and were provided with the necessary care. The main efficacy and safety parameters and relationships were analysed using descriptive statistics and Fisher ́s exact, Wilcoxon and Kruskal‒Wallis tests. RESULTS: A total of 65 stents were implanted in 47 adult patients. During the first two months after implantation, when adequate function was expected, the stent was found to be effective in 26 out of 39 patients who completed this period (66.7%). The clinical effectiveness reached 89.7%, as early restenoses were mostly mild and necessitated treatment in only 4 patients. The frequencies of significant mucostasis, migration and granulation tissue growth were 2.6%, 7.5% and 23.1%, respectively, during this period. Thirty-four participants completed the half-year follow-up period after the first or second stent insertion, and some were followed up beyond this period. Poor control of symptoms, the development of restenosis and the need for interventions were characteristic of this period as the stents degraded. Twenty-two patients who experienced remodelling or stabilization of the tracheal lumen achieved a stent-free state. Seven patients underwent subsequent surgical treatment. CONCLUSIONS: BD stents are safe and provide adequate tracheal support until they begin to degrade. The use of BD stents necessitates close monitoring of patients and accurate treatment of possible restenosis. TRIAL REGISTRATION: Based on project NT14146 - Biodegradable stents in the management of the large airways (2013-2015, MZ0/NT), registered on May 1, 2013, in the Research and Development and Innovation Information System of the Czech Republic and at ClinicalTrials.gov (reg. no. NCT02620319, December 2, 2015).
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24013916
- 003
- CZ-PrNML
- 005
- 20240905133921.0
- 007
- ta
- 008
- 240725s2024 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1186/s12890-024-03057-y $2 doi
- 035 __
- $a (PubMed)38750487
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Stehlik, Ludek $u Department of Respiratory Medicine, 1st Faculty of Medicine Charles University, Thomayer University Hospital, Videnska 800, Prague 4, 140 59, Czech Republic. ludek.stehlik@ftn.cz
- 245 10
- $a Biodegradable tracheal stents: our ten-year experience with adult patients / $c L. Stehlik, D. Guha, S. Anandakumar, A. Taskova, MK. Vasakova
- 520 9_
- $a BACKGROUND: Biodegradable (BD) stents made from polydioxanone have been used only in human airways. These stents combine the advantages of classical tracheal stents, and fewer side effects are expected due to their biocompatibility and their time-limited presence in airways. However, new clinical consequences have arisen. Here, the authors share their experiences with BD stents for tracheal indications, focusing on their safety and efficacy. METHODS: This was a retrospective review of a collected database of adult patients who underwent implantation of biodegradable tracheal stents between September 2013 and December 2022 at the Department of Respiratory Medicine of the 1st Faculty of Medicine in Prague and Thomayer University Hospital. The indications included functionally significant nonmalignant tracheal stenosis and tracheomalacia. Self-expandable, biodegradable, polydioxanone tracheal stents manufactured by ELLA-CS Ltd. (Hradec Kralove, Czech Republic) were implanted during rigid bronchoscopy under general anaesthesia. All patients were followed up in the department and were provided with the necessary care. The main efficacy and safety parameters and relationships were analysed using descriptive statistics and Fisher ́s exact, Wilcoxon and Kruskal‒Wallis tests. RESULTS: A total of 65 stents were implanted in 47 adult patients. During the first two months after implantation, when adequate function was expected, the stent was found to be effective in 26 out of 39 patients who completed this period (66.7%). The clinical effectiveness reached 89.7%, as early restenoses were mostly mild and necessitated treatment in only 4 patients. The frequencies of significant mucostasis, migration and granulation tissue growth were 2.6%, 7.5% and 23.1%, respectively, during this period. Thirty-four participants completed the half-year follow-up period after the first or second stent insertion, and some were followed up beyond this period. Poor control of symptoms, the development of restenosis and the need for interventions were characteristic of this period as the stents degraded. Twenty-two patients who experienced remodelling or stabilization of the tracheal lumen achieved a stent-free state. Seven patients underwent subsequent surgical treatment. CONCLUSIONS: BD stents are safe and provide adequate tracheal support until they begin to degrade. The use of BD stents necessitates close monitoring of patients and accurate treatment of possible restenosis. TRIAL REGISTRATION: Based on project NT14146 - Biodegradable stents in the management of the large airways (2013-2015, MZ0/NT), registered on May 1, 2013, in the Research and Development and Innovation Information System of the Czech Republic and at ClinicalTrials.gov (reg. no. NCT02620319, December 2, 2015).
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a retrospektivní studie $7 D012189
- 650 12
- $a stenty $7 D015607
- 650 12
- $a vstřebatelné implantáty $7 D020341
- 650 _2
- $a dospělí $7 D000328
- 650 12
- $a stenóza průdušnice $x chirurgie $7 D014135
- 650 _2
- $a senioři $7 D000368
- 650 12
- $a bronchoskopie $7 D001999
- 650 _2
- $a polydioxanon $7 D016687
- 650 _2
- $a tracheomalacie $x chirurgie $7 D055090
- 650 _2
- $a výsledek terapie $7 D016896
- 650 _2
- $a trachea $x chirurgie $7 D014132
- 650 _2
- $a protézy - design $7 D011474
- 650 _2
- $a mladý dospělý $7 D055815
- 651 _2
- $a Česká republika $7 D018153
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Guha, Debarya $u Department of Respiratory Medicine, 1st Faculty of Medicine Charles University, Thomayer University Hospital, Videnska 800, Prague 4, 140 59, Czech Republic
- 700 1_
- $a Anandakumar, Sheetal $u Department of Respiratory Medicine, 1st Faculty of Medicine Charles University, Thomayer University Hospital, Videnska 800, Prague 4, 140 59, Czech Republic
- 700 1_
- $a Taskova, Alice $u Department of Thoracic Surgery, 3rd Faculty of Medicine Charles University, Thomayer University Hospital, Videnska 800, Prague 4, 140 59, Czech Republic
- 700 1_
- $a Vasakova, Martina Koziar $u Department of Respiratory Medicine, 1st Faculty of Medicine Charles University, Thomayer University Hospital, Videnska 800, Prague 4, 140 59, Czech Republic
- 773 0_
- $w MED00008206 $t BMC pulmonary medicine $x 1471-2466 $g Roč. 24, č. 1 (2024), s. 238
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/38750487 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20240725 $b ABA008
- 991 __
- $a 20240905133915 $b ABA008
- 999 __
- $a ok $b bmc $g 2143620 $s 1225782
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2024 $b 24 $c 1 $d 238 $e 20240515 $i 1471-2466 $m BMC pulmonary medicine $n BMC Pulm Med $x MED00008206
- LZP __
- $a Pubmed-20240725