Ultra high performance liquid chromatography tandem mass spectrometric detection in clinical analysis of simvastatin and atorvastatin
Jazyk angličtina Země Nizozemsko Médium print-electronic
Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem
PubMed
19540175
DOI
10.1016/j.jchromb.2009.05.052
PII: S1570-0232(09)00387-0
Knihovny.cz E-zdroje
- MeSH
- anticholesteremika krev terapeutické užití MeSH
- atorvastatin MeSH
- hypercholesterolemie farmakoterapie MeSH
- kyseliny heptylové krev terapeutické užití MeSH
- lidé středního věku MeSH
- lidé MeSH
- pyrroly krev terapeutické užití MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- simvastatin krev terapeutické užití MeSH
- tandemová hmotnostní spektrometrie metody MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
- Názvy látek
- anticholesteremika MeSH
- atorvastatin MeSH
- kyseliny heptylové MeSH
- pyrroly MeSH
- simvastatin MeSH
Simvastatin and atorvastatin belong to the group of hypolipidemic drugs, more exactly to the second generation of inhibitors of microsomal 3-hydroxy-3-methylglutaryl-coenzyme A (HMG-CoA) reductase. They induce a significant reduction in total cholesterol, low-density lipoprotein cholesterol and plasma triglycerides, therefore they are widely used in the treatment of hypercholesterolemia even of its severe form-familiar hypercholesterolemia. Simvastatin and atorvastatin as the most widely used statins in clinical treatment and their hydroxy-acid/lactone forms were determined by means of UPLC in connection with triple quadrupole mass spectrometer. Deuterium labeled reference standard compounds were used as internal standards for the quantitation. Separation was performed on Acquity BEH C18 (100 mm x 2.1 mm, 1.7 microm) using gradient elution by mobile phase containing acetonitrile and ammonium acetate pH 4.0, which is convenient in order to prevent interconversion of analytes. ESI in positive mode was used for the ionization of all compounds. Two SRM (selected reaction monitoring) transitions were carefully optimized for each analyte in order to get high sensitivity and selectivity. SPE on Discovery DSC-18 was used as a sample preparation step. Intra-day precision was generally within 10% RSD, while inter-day precision within 15% RSD. Method accuracy expressed as recovery ranged from 75 to 100%. The method was validated with the sensitivity reaching LOQ 0.08-5.46 nmol/l and LOD 0.01-1.80 nmol/l in biological samples. Atorvastatin, simvastatin, its metabolites and hydroxy-acid/lactone forms were monitored in human serum and in lipoprotein fractions (LDL, HDL and VLDL) at patients with end stage renal diseases.