MicroRNA isolation and stability in stored RNA samples
Jazyk angličtina Země Spojené státy americké Médium print-electronic
Typ dokumentu časopisecké články, práce podpořená grantem, přehledy
PubMed
19769940
DOI
10.1016/j.bbrc.2009.09.061
PII: S0006-291X(09)01863-4
Knihovny.cz E-zdroje
- MeSH
- B-lymfocyty chemie MeSH
- chronická lymfatická leukemie diagnóza MeSH
- fenoly chemie MeSH
- guanidiny chemie MeSH
- lidé MeSH
- mikro RNA chemie izolace a purifikace MeSH
- odběr biologického vzorku MeSH
- polymerázová řetězová reakce MeSH
- reprodukovatelnost výsledků MeSH
- roztoky MeSH
- stabilita RNA * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Názvy látek
- fenoly MeSH
- guanidiny MeSH
- mikro RNA MeSH
- roztoky MeSH
- trizol MeSH Prohlížeč
MicroRNAs (miRNAs) are small RNA molecules, which act as post-transcriptional regulators of a gene expression, with important functions within the cell physiology. Whilst many authors have focused on the study of miRNA expression in physiological and pathological processes, various technical variables related to miRNA isolation have simultaneously emerged and the stability of the stored miRNA samples has been questioned. A robust method for RNA isolation is essential for reproducible results and miRNAs instability in the stored samples would make for an alarming situation for most expression studies. Here these issues are discussed and we investigate the stability of miRNAs isolated from clinical samples of B lymphocytes (chronic lymphocytic leukemia) by the most commonly utilized method based on a Trizol/TRI-Reagent solution (RNAs stored at -80 degrees C). To assess the stability of miRNAs, a Real Time-PCR analysis was performed for a panel of 29 miRNAs from a freshly isolated RNA sample and after 14 days storage at -80 degrees C. Furthermore, a Real Time-PCR analysis was repeatedly performed for a stored RNA sample over a period of approximately 10 months. We observed high stability of isolated miRNAs and respective cDNAs. The reproducibility and efficiency of the Trizol/TRI-Reagent isolation method was also tested and compared to the mirVana Isolation kit (Ambion) and RNeasy kit (Qiagen). In conclusion, Trizol/TRI-Reagent based isolation is a robust reproducible method, and obtained miRNA samples do not show any tendency to degradation when properly stored and handled.
Citace poskytuje Crossref.org
Identification of novel sequence variations in microRNAs in chronic lymphocytic leukemia