Improvement of MALDI-TOF MS profiling for the differentiation of species within the Acinetobacter calcoaceticus-Acinetobacter baumannii complex
Jazyk angličtina Země Německo Médium print-electronic
Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem
PubMed
24054697
DOI
10.1016/j.syapm.2013.08.001
PII: S0723-2020(13)00135-5
Knihovny.cz E-zdroje
- Klíčová slova
- ACB complex, Acinetobacter calcoaceticus–Acinetobacter baumannii complex, Bacteria profiling, BioTyper, CHCA, FA, FerA, MALDI-TOF MS, Matrix-Assisted Laser Desorption Ionization-Time-of-Flight Mass Spectrometry, TFA, UPGMA, alpha-cyano-4-hydroxycinnamic acid, ferulic acid, formic acid, trifluoroacetic acid, unweighted pair group average linked method,
- MeSH
- Acinetobacter chemie klasifikace izolace a purifikace MeSH
- bakteriologické techniky metody MeSH
- odběr biologického vzorku metody MeSH
- shluková analýza MeSH
- spektrometrie hmotnostní - ionizace laserem za účasti matrice metody MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
MALDI-TOF MS is currently becoming the method of choice for rapid identification of bacterial species in routine diagnostics. Yet, this method suffers from the inability to differentiate reliably between some closely related bacterial species including those of the Acinetobacter calcoaceticus-Acinetobacter baumannii (ACB) complex, namely A. baumannii and Acinetobacter nosocomialis. In the present study, we evaluated a protocol which was different from that used in the Bruker Daltonics identification system (MALDI BioTyper) to improve species identification using a taxonomically precisely defined set of 105 strains representing the four validly named species of the ACB complex. The novel protocol is based on the change in matrix composition from alpha-cyano-4-hydroxycinnamic acid (saturated solution in water:acetonitrile:trifluoroacetic acid, 47.5:50:2.5, v/v) to ferulic acid (12.5mgml(-1) solution in water:acetonitrile:formic acid 50:33:17, v/v), while the other steps of sample processing remain unchanged. Compared to the standard protocol, the novel one extended the range of detected compounds towards higher molecular weight, produced signals with better mass resolution, and allowed the detection of species-specific signals. As a result, differentiation of A. nosocomialis and A. baumannii strains by cluster analysis was improved and 13 A. nosocomialis strains, assigned erroneously or ambiguously by using the standard protocol, were correctly identified.
Citace poskytuje Crossref.org