Noninvasive Blood Pressure Monitor Designed for Patients With Heart Failure Supported with Continuous-Flow Left Ventricular Assist Devices
Language English Country United States Media print
Document type Journal Article, Research Support, N.I.H., Extramural, Research Support, Non-U.S. Gov't
Grant support
R01 HL071478
NHLBI NIH HHS - United States
PubMed
29538016
PubMed Central
PMC6136985
DOI
10.1097/mat.0000000000000775
Knihovny.cz E-resources
- MeSH
- Arterial Pressure physiology MeSH
- Middle Aged MeSH
- Humans MeSH
- Blood Pressure Determination instrumentation MeSH
- Blood Pressure Monitors * MeSH
- Heart-Assist Devices * MeSH
- Reproducibility of Results MeSH
- Heart Failure physiopathology therapy MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Research Support, N.I.H., Extramural MeSH
The gold standard for noninvasive blood pressure (BP) measurement, the Doppler technique, does not provide systolic blood pressure (SBP) and diastolic blood pressure (DBP) and may limit therapy outcomes. To improve patient care, we tested specifically designed experimental BP (ExpBP) monitor and the Doppler technique by comparing noninvasive measures to the intraarterial (I-A) BP in 31 patients with end-stage heart failure (4 females) 2.6 ± 3.4 days post-LVAD implantation (20 HeartMate II and 11 HeartWare). Bland-Altman plots revealed that the ExpBP monitor overestimated mean arterial pressure (MAP) by 1.2 (4.8) mm Hg (mean difference [standard deviation]), whereas the Doppler by 6.7 (5.8) mm Hg. The ExpBP SBP was overestimated by 0.8 (6.1) mm Hg and DBP by 1.9 (5.3) mm Hg compared with the respective I-A pressures. Both techniques achieved similar measurement reliability. In the measurement "success rate" expressed as a frequency (percent) of readable BP values per measurement attempts, Doppler accomplished 100% vs. 97%, 97%, and 94% of successful detections of MAP, SBP, and DBP provided by the ExpBP monitor. The ExpBP monitor demonstrated higher accuracy in the MAP assessment than the Doppler in addition to providing SBP and DBP in majority of subjects. Improved BP control may help to mitigate related neurologic adverse event rates.
Department of Cardiovascular Surgery Mayo Clinic Rochester Minnesota
Department of Neurology Mayo Clinic Rochester Minnesota
From the Department of Cardiovascular Diseases Mayo Clinic Rochester Minnesota
See more in PubMed
Heidenreich Pa, Albert NM, Allen La, et al. Forecasting the impact of heart failure in the united states a policy statement from the american heart association. Circ Hear Fail. 2013;6:606–619. doi: 10.1161/HHF.0b013e318291329a. PubMed DOI PMC
Stehlik J, Edwards LB, Kucheryavaya AY, et al. The Registry of the International Society for Heart and Lung Transplantation: 29th Official Adult Heart Transplant Report—2012. J Hear Lung Transplant. 2012;31:1052–1064. doi: 10.1016/j.healun.2012.08.002. PubMed DOI
Kirklin JK, Naftel DC, Pagani FD, et al. INTERMACS ANNUAL REPORT Seventh INTERMACS annual report: 15,000 patients and counting. J Hear Lung Transplant. 2015;34:1495–1504. doi: 10.1016/j.healun.2015.10.003. PubMed DOI
Bennett MK, Roberts Ca, Dordunoo D, Shah A, Russell SD. Ideal methodology to assess systemic blood pressure in patients with continuous-flow left ventricular assist devices. J Heart Lung Transplant. 2010;29(5):593–594. doi: 10.1016/j.healun.2009.11.604. PubMed DOI
Lanier GM, Orlanes K, Hayashi Y, et al. Validity and reliability of a novel slow cuff-deflation system for noninvasive blood pressure monitoring in patients with continuous-flow left ventricular assist device. Circ Hear Fail. 2013;6:1005–1012. doi: 10.1161/CIRCHEARTFAILURE.112.000186. PubMed DOI
Teuteberg JJ, Ewald GA, Adamson RM, et al. Risk assessment for continuous flow left ventricular assist devices: does the destination therapy risk score work? An analysis of over 1,000 patients. J Am Coll Cardiol. 2012;60(1):44–51. doi: 10.1016/j.jacc.2012.02.032S0735-1097(12)01058-3. [pii] PubMed DOI
Saeed O, Jermyn R, Kargoli F, et al. Blood Pressure and Adverse Events During Continuous Flow Left Ventricular Assist Device Support. Circ Hear Fail. 2015 doi: 10.1161/CIRCHEARTFAILURE.114.002000. PubMed DOI
Lampert B, Weaver S, Scanlon A, et al. Blood Pressure Control in Continuous Flow Left Ventricular Assist Devices – Efficacy and Impact on Adverse Events. J Hear Lung Transplant. 2012;31(4):S251. doi: 10.1016/j.healun.2012.01.750. PubMed DOI
Hollenberg SM. Hemodynamic monitoring. Chest. 2013;143(5):1480–1488. doi: 10.1378/chest.12-1901. PubMed DOI
Cecconi M, De Backer D, Antonelli M, et al. Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2014;40(12):1795–1815. doi: 10.1007/s00134-014-3525-z. PubMed DOI PMC
Pickering TGT, Hall JJE, Appel LJL, et al. Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Cou. Hypertension. 2005;111(45):697–716. doi: 10.1161/01.CIR.0000154900.76284.F6. PubMed DOI
Posey JA, Geddes LA, Williams H, Moore AG. The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure. 1. [Accessed July 16, 2017];Cardiovasc Res Cent Bull. 8(1):15–25. http://www.ncbi.nlm.nih.gov/pubmed/5357773. PubMed
Zheng D, Amoore JN, Mieke S, Murray A. Estimation of mean arterial pressure from the oscillometric cuff pressure: comparison of different techniques. Med Biol Eng Comput. 2011;49(1):33–39. doi: 10.1007/s11517-010-0694-y. PubMed DOI
BRONZINO JD. Biomedical Engineering Handbook. Trinity College, Hartford, Connecticut, USA: CRC press; 1999.
Sorvoja H, Myllylä R. NONINVASIVE BLOOD PRESSURE MEASUREMENT METHODS. [Accessed July 16, 2017];Mol Quantum Acoust. 2006 :27. https://pdfs.semanticscholar.org/8f83/e5a0c79b099a9eda08c9e822510ea9f393ed.pdf.
Fabian V, Havlik J, Dvorak J, et al. Differences in mean arterial pressure of young and elderly people measured by oscilometry during inflation and deflation of the arm cuff. Biomed Tech (Berl) 2016:1–11. doi: 10.1515/bmt-2015-0098. PubMed DOI
Forouzanfar M, Dajani HR, Groza VZ, Bolic M, Rajan S, Batkin I. Oscillometric blood pressure estimation: Past, present, and future. IEEE Rev Biomed Eng. 2015;8:44–63. doi: 10.1109/RBME.2015.2434215. PubMed DOI
O’Brien Eoin, William L, De Swiet M, et al. The British Hypertension society protocol for the evaluation of blood pressure measuring devices. J Hypertens. 1993:19. PubMed
American National Standard ANSI/AAMI/ISA 81060-2. 2013. Non-Invasive Sphygmomanometers-Part 2: Clinical Validation of Automated Measurement Type.
Cheng A, Williamitis Ca, Slaughter MS. Comparison of continuous-flow and pulsatile-flow left ventricular assist devices : is there an advantage to pulsatility? 2014;3(6):573–581. doi: 10.3978/j.issn.2225-319X.2014.08.24. PubMed DOI PMC
Edwards AL, Fitzmorris PS, Hairrell AO, et al. Mo2020 Low Pulsatility Index Is Associated With an Increased Hazard of Gastrointestinal Bleeding in Patients With Continuous-Flow Left Ventricular Assist Devices. Gastroenterology. 2015;148(4):S-770–S-771. doi: 10.1016/S0016-5085(15)32629-9. DOI
Castagna F, McDonnell BJ, Stöhr EJ, et al. Non-invasive measurement of peripheral, central and 24-hour blood pressure in patients with continuous-flow left ventricular assist device. J Hear Lung Transplant. 2017;36(6):694–697. doi: 10.1016/j.healun.2017.02.026. PubMed DOI
Markham DW, Drazner MH. Measuring nonpulsatile blood pressure: say goodbye to the Doppler? Circ Heart Fail. 2013;6(5):879–880. doi: 10.1161/CIRCHEARTFAILURE.113.000579. PubMed DOI
Slaughter MS, Pagani FD, Rogers JG, et al. Clinical management of continuous-flow left ventricular assist devices in advanced heart failure. J Hear Lung Transpl. 2010;29(4 Suppl):S1–39. doi: 10.1016/j.healun.2010.01.011S1053-2498(10)00043-4. [pii] PubMed DOI
Park SJ, Milano CA, Tatooles AJ, et al. Outcomes in advanced heart failure patients with left ventricular assist devices for destination therapy. Circ Hear Fail. 2012;5(2):241–248. doi: 10.1161/CIRCHEARTFAILURE.111.963991. PubMed DOI
Rogers JG, Aaronson KD, Boyle AJ, et al. Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients. J Am Coll Cardiol. 2010;55(17):1826–1834. doi: 10.1016/j.jacc.2009.12.052S0735-1097(10)01022-3. [pii] PubMed DOI
Feasibility of Brachial Occlusion Technique for Beat-to-Beat Pulse Wave Analysis