VISUAL FIELD ASSESSMENT IN HYPERTENSION GLAUCOMA
Language English Country Czech Republic Media print
Document type Journal Article
PubMed
33740864
DOI
10.31348/2021/2
PII: 126208
Knihovny.cz E-resources
- Keywords
- brimonidin, hypertension glaucoma, overall defekt, pattern defect, perimetry test,
- MeSH
- Glaucoma * complications diagnosis MeSH
- Hypertension * MeSH
- Humans MeSH
- Intraocular Pressure MeSH
- Ocular Hypertension * MeSH
- Visual Field Tests MeSH
- Visual Fields MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
AIMS: The aim of the work is to verify the necessity of full-field perimetry test in incipient glaucoma. MATERIAL AND METHODS: The study included group of 16 incipient hypertension glaucoma (HTG group) patients without obvious changes in visual field and control group of 10 patients with normal ocular findings and value 1.0 of visual acuity. In both groups, full-field perimetry test was performed followed by a glaucoma perimetry test (rapid threshold strategy in both cases). Evaluated parameters were pattern defect (PD) and overall defect (OD) using Pearsons correlation coefficient. RESULTS: Strong correlation coefficient between PD (r = 0.74) and OD (r = 0.63) of both perimetry test were found in HTG group. Moderate correlation of PD (r = 0.54) and strong correlation of OD (r = 0.64) in control group. CONCLUSION: Results of the study shows, that expected changes of peripheral visual field will be recorded first in HTG group, but opposite is true. Perimetry glaucoma test is for incipient glaucoma sufficient to document the course and the examination of glaucoma disease.
References provided by Crossref.org
Distal Nasal Part of the Visual Field and RNFL in Primary Open-Angle Glaucoma
The Relationship Between the Thickness of cpRNFL in Segments and Intraocular Pressure
Comparison of the Effect on Vessel Density and RNFL between Carteolol and Latanoprost
OCT angiography, RNFL and the visual field at different values of intraocular pressure