Left bundle branch pacing compared to left ventricular septal myocardial pacing increases interventricular dyssynchrony but accelerates left ventricular lateral wall depolarization

. 2021 Aug ; 18 (8) : 1281-1289. [epub] 20210428

Jazyk angličtina Země Spojené státy americké Médium print-electronic

Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/pmid33930549

Odkazy
PubMed 33930549
DOI 10.1016/j.hrthm.2021.04.025
PII: S1547-5271(21)00402-1
Knihovny.cz E-zdroje

BACKGROUND: Nonselective His-bundle pacing (nsHBp), nonselective left bundle branch pacing (nsLBBp), and left ventricular septal myocardial pacing (LVSP) are recognized as physiological pacing techniques. OBJECTIVE: The purpose of this study was to compare differences in ventricular depolarization between these techniques using ultra-high-frequency electrocardiography (UHF-ECG). METHODS: In patients with bradycardia, nsHBp, nsLBBp (confirmed concomitant left bundle branch [LBB] and myocardial capture), and LVSP (pacing in left ventricular [LV] septal position without proven LBB capture) were performed. Timings of ventricular activations in precordial leads were displayed using UHF-ECG, and electrical dyssynchrony (e-DYS) was calculated as the difference between the first and last activation. Duration of local depolarization (Vd) was determined as width of the UHF-QRS complex at 50% of its amplitude. RESULTS: In 68 patients, data were collected during nsLBBp (35), LVSP (96), and nsHBp (55). nsLBBp resulted in larger e-DYS than did LVSP and nsHBp [- 24 ms (-28;-19) vs -12 ms (-16;-9) vs 10 ms (7;14), respectively; P <.001]. nsLBBp produced similar values of Vd in leads V5-V8 (36-43 ms vs 38-43 ms; P = NS in all leads) but longer Vd in leads V1-V4 (47-59 ms vs 41-44 ms; P <.05) as nsHBp. LVSP caused prolonged Vd in leads V1-V8 compared to nsHBp and longer Vd in leads V5-V8 compared to nsLBBp (44-51 ms vs 36-43 ms; P <.05) regardless of R-wave peak time in lead V5 or QRS morphology in lead V1 present during LVSP. CONCLUSION: nslbbp preserves physiological LV depolarization but increases interventricular electrical dyssynchrony. LV lateral wall depolarization during LVSP is prolonged, but interventricular synchrony is preserved.

Komentář v

PubMed

Nejnovějších 20 citací...

Zobrazit více v
Medvik | PubMed

Ultra-high-frequency ECG volumetric and negative derivative epicardial ventricular electrical activation pattern

. 2024 Mar 07 ; 14 (1) : 5681. [epub] 20240307

Ultra-High-Frequency ECG in Cardiac Pacing and Cardiac Resynchronization Therapy: From Technical Concept to Clinical Application

. 2024 Feb 23 ; 11 (3) : . [epub] 20240223

Left ventricular septal pacing - can we trust the ECG?

. 2023 Sep-Oct ; 23 (5) : 155-157. [epub] 20230708

Left ventricular resynchronization with left bundle branch area pacing: does the type of capture matter?

. 2023 Jun 02 ; 25 (6) : .

Left bundle branch area pacing results in more physiological ventricular activation than biventricular pacing in patients with left bundle branch block heart failure

. 2023 Jun ; 25 (Suppl E) : E17-E24. [epub] 20230524

Pacing of the specialized His-Purkinje conduction system: 'back to the future'

. 2023 May ; 25 (Suppl C) : C234-C241. [epub] 20230426

EHRA clinical consensus statement on conduction system pacing implantation: endorsed by the Asia Pacific Heart Rhythm Society (APHRS), Canadian Heart Rhythm Society (CHRS), and Latin American Heart Rhythm Society (LAHRS)

. 2023 Apr 15 ; 25 (4) : 1208-1236.

EHRA clinical consensus statement on conduction system pacing implantation: executive summary. Endorsed by the Asia-Pacific Heart Rhythm Society (APHRS), Canadian Heart Rhythm Society (CHRS) and Latin-American Heart Rhythm Society (LAHRS)

. 2023 Apr 15 ; 25 (4) : 1237-1248.

Bipolar anodal septal pacing with direct LBB capture preserves physiological ventricular activation better than unipolar left bundle branch pacing

. 2023 ; 10 () : 1140988. [epub] 20230322

Ventricular Dyssynchrony and Pacing-induced Cardiomyopathy in Patients with Pacemakers, the Utility of Ultra-high-frequency ECG and Other Dyssynchrony Assessment Tools

. 2022 Apr ; 11 () : e17.

Left Ventricular Myocardial Septal Pacing in Close Proximity to LBB Does Not Prolong the Duration of the Left Ventricular Lateral Wall Depolarization Compared to LBB Pacing

. 2021 ; 8 () : 787414. [epub] 20211207

Najít záznam

Citační ukazatele

Nahrávání dat...

Možnosti archivace

Nahrávání dat...