- Publikační typ
- abstrakt z konference MeSH
- Publikační typ
- abstrakt z konference MeSH
- Publikační typ
- abstrakt z konference MeSH
- Publikační typ
- abstrakt z konference MeSH
A high-throughput miniaturized liquid-liquid extraction procedure followed by a simple ultra-high performance liquid chromatography method coupled with fluorescence detection for bioanalytical analysis of all tocopherol isomers and retinol in human serum has been developed and validated. In the extraction procedure, a synthetic internal standard tocol was used, which does not occur in the human body. The separation of structurally related vitamins was achieved using a new generation of pentafluorophenyl propyl core-shell stationary phase with elution using methanol and an aqueous solution of ammonium acetate. The fluorescence of retinol and tocopherol isomers was detected at λex = 325, 295 nm and λem = 480, 325 nm, respectively. The rapid baseline separation of all analytes was accomplished within 4.0 min. The sensitivity of method was demonstrated with lower limits of quantification: retinol 0.01 μM, α-tocopherol 0.38 μM, β-tocopherol 0.18 μM, γ-tocopherol 0.14 μM, and δ-tocopherol 0.01 μM. Possible application of this method in clinical practice was confirmed by the analysis of human serum samples from healthy volunteers. Finally, the simultaneous determination of retinol and all tocopherol isomers in human serum can enable the clarification of their role in metabolism and in diseases such as cancer.
- Publikační typ
- abstrakt z konference MeSH
AIM: A new HPLC method for the determination of neopterin, kynurenine and tryptophan using a second-generation monolith stationary phase and high-throughput sample preparation procedure based on microplates was developed and fully validated. MATERIALS & METHODS: As the stationary phase a monolithic C18 Chromolith high-resolution column with dimensions of 4.6 × 100 mm connected to a monolithic 4.6 × 10-mm security guard was used. Separation was achieved using 15 mM phosphate buffer (KH2PO4 +K2HPO4·3H2O at pH 3) and acetonitrile in gradient mode. RESULTS: Target analytes were determined in 5.5 minutes in amniotic fluid, effusions and wound exudates with a limit of quantification (LOQ) of 1.25 nM for neopterin, 2.5 µM for tryptophan and 0.25 µM for kynurenine. DISCUSSION: The method was applied to real clinical sample measurements, and it will be used to monitor neopterin, kynurenine and tryptophan levels in biological fluids to assess the patient response to therapy and clinical status.
- MeSH
- exsudáty a transsudáty metabolismus MeSH
- hojení ran * MeSH
- kynurenin analýza MeSH
- lidé MeSH
- maligní pleurální výpotek metabolismus MeSH
- neopterin analýza MeSH
- plodová voda metabolismus MeSH
- spektrofotometrie ultrafialová MeSH
- tryptofan analýza MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH