BACKGROUND: The subcutaneous implantable defibrillator (S-ICD) provides an alternative to the transvenous ICD for the prevention of sudden cardiac death, but has not been well studied in the most commonly treated transvenous ICD patient population, namely, primary prevention (PP) patients with left ventricular dysfunction. OBJECTIVE: The analyses in the present study were designed to compare clinical outcomes for PP patients with and without a reduced ejection fraction (EF) and secondary prevention (SP) patients implanted with the S-ICD. METHODS: All patients 18 years and older from the S-ICD IDE study and the EFFORTLESS Registry with available data as of November 18, 2013, were included (n = 856; mean follow-up duration 644 days). Outcomes were evaluated in 2 analyses: (1) comparing all PP patients (n = 603, 70.4%) with all SP patients (n = 253, 29.6%) and (2) comparing all PP patients with an EF ≤35% (n = 379) with those with an EF >35% (n = 149, 17.4%). RESULTS: No differences were observed in mortality, complications, inappropriate therapy, or ability to convert ventricular tachyarrhythmias between SP and PP patients. However, SP patients had a higher incidence of appropriate therapy than did PP patients (11.9% vs 5.0%; P = .0004). In the PP subanalysis, the cohort with an EF ≤35% had significantly older patients with more comorbidities and higher mortality (3.0% annually vs 0.0%). Despite these differences, device-related complications, conversion efficacy, and incidence of inappropriate shock therapies were not significantly different between PP subgroups. CONCLUSION: The S-ICD performs well in protecting patients with either PP or SP implant indications from sudden cardiac death. Within PP patients, device performance was independent of EF.
- MeSH
- defibrilátory implantabilní * MeSH
- dospělí MeSH
- dysfunkce levé srdeční komory * diagnóza patofyziologie MeSH
- elektrická defibrilace * škodlivé účinky přístrojové vybavení metody MeSH
- Kaplanův-Meierův odhad MeSH
- komorová tachykardie * mortalita terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhlá srdeční smrt prevence a kontrola MeSH
- primární prevence metody statistika a číselné údaje MeSH
- protetické vybavení MeSH
- registrace MeSH
- sekundární prevence metody statistika a číselné údaje MeSH
- senioři MeSH
- tepový objem MeSH
- výsledky a postupy - zhodnocení (zdravotní péče) MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) provides an alternative to the transvenous implantable cardioverter-defibrillator (TV-ICD). Patients undergoing TV-ICD explantation may be eligible for reimplantation with an S-ICD; however, information on safety outcomes in this complex population is limited. OBJECTIVE: This analysis was designed to provide outcome and safety data from S-ICD patients who received their device after TV-ICD explantation. METHODS: Patients in the S-ICD IDE Study and EFFORTLESS Registry with a prior TV-ICD explantation, as well as those with no prior implantable cardioverter-defibrillator (ICD), were included. Patients were divided into 3 groups: those implanted with the S-ICD after TV-ICD extraction for system-related infection (n = 75); those implanted after TV-ICD extraction for reasons other than system-related infection (n = 44); and patients with no prior ICD (de novo implantations, n = 747). RESULTS: Mean follow-up duration was 651 days, and all-cause mortality was low (3.2%). Patients previously explanted for TV-ICD infection were older (55.5 ± 14.6, 47.8 ± 14.3 and 49.9 ± 17.3 years in the infection, noninfection, and de novo cohorts, respectively; P = .01), were more likely to have received the ICD for secondary prevention (42.7%, 37.2% and 25.6%; P < 0.0001) and had higher percentages of comorbidities, including atrial fibrillation, congestive heart failure, diabetes mellitus, and hypertension, in line with the highest mortality rate (6.7%). Major infection after S-ICD implantation was low in all groups, with no evidence that patients implanted with the S-ICD after TV-ICD explantation for infection were more likely to experience a subsequent reinfection. CONCLUSION: The S-ICD is a suitable alternative for TV-ICD patients whose devices are explanted for any reason. Postimplantation risk of infection remains low even in patients whose devices were explanted for prior TV-ICD infection.
- MeSH
- analýza přežití MeSH
- defibrilátory implantabilní * škodlivé účinky statistika a číselné údaje MeSH
- dospělí MeSH
- elektrická defibrilace přístrojové vybavení metody MeSH
- implantace protézy * škodlivé účinky metody mortalita MeSH
- infekce chirurgické rány * diagnóza epidemiologie terapie MeSH
- komorová tachykardie terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- reoperace statistika a číselné údaje MeSH
- selhání zařízení statistika a číselné údaje MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH