PURPOSE: STereotactic Arrhythmia Radioablation (STAR) showed promising results in patients with refractory ventricular tachycardia. However, clinical data are scarce and heterogeneous. The STOPSTORM.eu consortium was established to investigate and harmonize STAR in Europe. The primary goal of this benchmark study was to investigate current treatment planning practice within the STOPSTORM project as a baseline for future harmonization. METHODS AND MATERIALS: Planning target volumes (PTVs) overlapping extracardiac organs-at-risk and/or cardiac substructures were generated for 3 STAR cases. Participating centers were asked to create single-fraction treatment plans with 25 Gy dose prescriptions based on in-house clinical practice. All treatment plans were reviewed by an expert panel and quantitative crowd knowledge-based analysis was performed with independent software using descriptive statistics for International Commission on Radiation Units and Measurements report 91 relevant parameters and crowd dose-volume histograms. Thereafter, treatment planning consensus statements were established using a dual-stage voting process. RESULTS: Twenty centers submitted 67 treatment plans for this study. In most plans (75%) intensity modulated arc therapy with 6 MV flattening filter free beams was used. Dose prescription was mainly based on PTV D95% (49%) or D96%-100% (19%). Many participants preferred to spare close extracardiac organs-at-risk (75%) and cardiac substructures (50%) by PTV coverage reduction. PTV D0.035cm3 ranged from 25.5 to 34.6 Gy, demonstrating a large variety of dose inhomogeneity. Estimated treatment times without motion compensation or setup ranged from 2 to 80 minutes. For the consensus statements, a strong agreement was reached for beam technique planning, dose calculation, prescription methods, and trade-offs between target and extracardiac critical structures. No agreement was reached on cardiac substructure dose limitations and on desired dose inhomogeneity in the target. CONCLUSIONS: This STOPSTORM multicenter treatment planning benchmark study not only showed strong agreement on several aspects of STAR treatment planning, but also revealed disagreement on others. To standardize and harmonize STAR in the future, consensus statements were established; however, clinical data are urgently needed for actionable guidelines for treatment planning.
- MeSH
- benchmarking * MeSH
- celková dávka radioterapie MeSH
- komorová tachykardie chirurgie radioterapie MeSH
- konsensus * MeSH
- kritické orgány * účinky záření MeSH
- lidé MeSH
- plánování radioterapie pomocí počítače * normy metody MeSH
- radiochirurgie * normy metody MeSH
- radioterapie s modulovanou intenzitou metody normy MeSH
- srdce účinky záření MeSH
- srdeční arytmie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Geografické názvy
- Evropa MeSH
BACKGROUND/PURPOSE: High doses to healthy cardiac substructures (CS) in stereotactic arrhythmia radioablation (STAR) raise concerns regarding potential treatment-induced cardio-toxicity. However, CS contours are not routinely created, hindering the understanding of the CS dose-effect relationships. To address this issue, the alignment of CS contouring was initiated within the STOPSTORM consortium. In this study, we developed and evaluated auto-contouring models trained to delineate CS and major vessels in ventricular tachycardia (VT) patients. METHODS: Eight centres provided standard treatment planning computed tomography (CT) and/or contrast-enhanced CT datasets of 55 VT patients, each including 16 CS. Auto-contouring models were trained to contour either large structures or small structures. Dice Similarity Coefficient (DSC), 95 % Hausdorff distance (HD95) and volume ratio (VR) were used to evaluate model performance versus inter-observer variation (IOV) on seven VT patient test cases. Significant differences were tested using the Mann-Whitney U test. RESULTS: The performance on the four chambers and the major vessels (median DSC: 0.88; HD95: 5.8-19.4 mm; VR: 1.09) was similar to the IOV (median DSC: 0.89; HD95: 4.8-14.0 mm; VR: 1.20). For the valves, model performance (median DSC: 0.37; HD95: 11.6 mm; VR: 1.63) was similar to the IOV (median DSC: 0.41; HD95: 12.4 mm; VR: 3.42), but slightly worse for the coronary arteries (median DSC: 0.33 vs 0.42; HD95: 24.4 mm vs 16.9 mm; VR: 1.93 vs 3.30). The IOV for these small structures remains large despite using contouring guidelines. CONCLUSION: CS auto-contouring models trained on VT patient data perform similarly to IOV. This allows for time-efficient evaluation of CS as possible organs-at-risk.
- MeSH
- komorová tachykardie * MeSH
- kritické orgány účinky záření MeSH
- lidé středního věku MeSH
- lidé MeSH
- plánování radioterapie pomocí počítače metody MeSH
- počítačová rentgenová tomografie * MeSH
- radiochirurgie * metody MeSH
- senioři MeSH
- srdce účinky záření MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
The EU Horizon 2020 Framework-funded Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary (STOPSTORM) consortium has been established as a large research network for investigating STereotactic Arrhythmia Radioablation (STAR) for ventricular tachycardia (VT). The aim is to provide a pooled treatment database to evaluate patterns of practice and outcomes of STAR and finally to harmonize STAR within Europe. The consortium comprises 31 clinical and research institutions. The project is divided into nine work packages (WPs): (i) observational cohort; (ii) standardization and harmonization of target delineation; (iii) harmonized prospective cohort; (iv) quality assurance (QA); (v) analysis and evaluation; (vi, ix) ethics and regulations; and (vii, viii) project coordination and dissemination. To provide a review of current clinical STAR practice in Europe, a comprehensive questionnaire was performed at project start. The STOPSTORM Institutions' experience in VT catheter ablation (83% ≥ 20 ann.) and stereotactic body radiotherapy (59% > 200 ann.) was adequate, and 84 STAR treatments were performed until project launch, while 8/22 centres already recruited VT patients in national clinical trials. The majority currently base their target definition on mapping during VT (96%) and/or pace mapping (75%), reduced voltage areas (63%), or late ventricular potentials (75%) during sinus rhythm. The majority currently apply a single-fraction dose of 25 Gy while planning techniques and dose prescription methods vary greatly. The current clinical STAR practice in the STOPSTORM consortium highlights potential areas of optimization and harmonization for substrate mapping, target delineation, motion management, dosimetry, and QA, which will be addressed in the various WPs.
- MeSH
- katetrizační ablace * škodlivé účinky metody MeSH
- komorová tachykardie * MeSH
- lidé MeSH
- prospektivní studie MeSH
- srdeční arytmie MeSH
- srdeční komory MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH