Cíl: Zhodnotit data zjištěná pomocí poměrně nových přístrojů a jejich výsledky, které jsou důležité např. v refrakční a kataraktové chirurgii. Materiál a metodika: Do studie bylo zařazeno 66 očí (n = 66). Subjekty byly zastoupeny 32 ženami a 1 mužem, jejichž věk činil 22,5 let ? 1,2 let (min. 21 let, max. 26 let), bez známek možného očního onemocnění. Doba studie byla 3 měsíce. Srovnávaly se výsledky změřené pomocí auto-refrakto-keratro-tono-pachymetru (TRK 1P, Topcon, Japan), Keratograph 5M (Oculus, Germany) a aberometru iTRACE (Hoya, Japan). Výsledky: Po 3 měsících se statisticky porovnávaly hodnoty keratometrie přední plochy rohovky, zjištěné všemi přístroji. Ty se ukázaly jako srovnatelné. Dále pak hodnoty objektivní refrakce a pachymetrie. Závěr: Výsledky této studie ukazují na statisticky významnou korelaci hodnot objektivní refrakce pomocí přístrojů TRK a iTRACE (r = 0,66 na p = 0,05) a prokázala se významná závislost mezi keratometrickými daty u všech použitých přístrojů. Všechny použité metody a přístroje je tedy možné aplikovat ke spolehlivému a validnímu zhodnocení parametrů oka. Klíčová slova: aberometrie, aberace nižších a vyšších řádů, keratometrie, topografie, pachymetrie
Purpose: To evaluate obtained data by using a relatively novel devices and their results which are important eg. in refractive and cataract surgery. Material and methods: The study included 66 eyes (n = 66). Subjects were represented by 32 women and 1 man whose age was 22.5 years ? 1.2 years (min. 21, max. 26 years) without any signs of potential eye disease. Duration of the study was 3 months. Results were compared with the measurements using the auto-refract-keratro-tono-pachymeter (TRK 1P, Topcon, Japan), Keratograph 5M (Oculus, Germany) and aberrometer iTRACE (Hoya, Japan). Results: After 3 months were statistically compared keratometry values of corneal anterior surface detected by all devices. They provided to be comparable. Furthermore the values of objective refraction and pachymetry were detected. Conclusion: Results of this study show a statistically significant correlation values of objective refraction using devices TRK and iTRACE (r = 0.66 at p = 0.05) and showed a significant relationship between the keratometric data for all the devices. All used methods and devices are possible to reliably and use for valid evaluation parameters of the eye. Key words: aberrometry, low and high orders abberations, keratometry, topography, pachymetry
- MeSH
- Aberrometry * classification instrumentation utilization MeSH
- Contrast Sensitivity MeSH
- Diagnostic Techniques, Ophthalmological instrumentation MeSH
- Adult MeSH
- Humans MeSH
- Young Adult MeSH
- Randomized Controlled Trials as Topic MeSH
- Refraction, Ocular MeSH
- Refractometry * MeSH
- Cornea MeSH
- Corneal Topography MeSH
- Statistics as Topic MeSH
- Visual Acuity physiology MeSH
- Check Tag
- Adult MeSH
- Humans MeSH
- Young Adult MeSH