"Progres Q38/LF1" Dotaz Zobrazit nápovědu
Balloon pulmonary angioplasty (BPA) is a novel treatment option for patients with chronic thromboembolic pulmonary hypertension (CTEPH) who are not eligible for pulmonary endarterectomy (PEA) or suffer from persistent pulmonary hypertension after PEA. The aim of this study was to evaluate the real-life efficacy and safety of BPA in a consecutive group of patients who were diagnosed and treated in the national referral center for CTEPH in the Czech Republic. Here we report data from 160 BPA procedures performed in 64 patients. Efficacy analysis was performed in the subgroup of 25 patients who completed BPA series. Significant improvements were observed in New York Heart Association functional class (4% to 79% in I/II, p < 0.001), 6 min walking test distance (+54.3 m, p < 0.001), risk profile (15.8% to 68.5% with presence of 2/3 low risk criteria, p < 0.001), pulmonary artery mean pressure (-18%, p < 0.001), pulmonary vascular resistance (-32%, p < 0.001), stroke volume (+17%, p = 0.011) and quality of life (+37% in assessment of overall health status by a patient, p < 0.001). We observed 1 fatal periprocedural complication (1.6% of all 64 patients) and 19 BPA-related non-fatal complications (11.9% of all 160 interventions) that predominantly included hemoptysis (10.0% of all sessions). Overall survival at 12 months was 94.6%.
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Normative reference values for echocardiographic chamber quantification are of great importance; however, this can be challenging. Our aim was to derive these values including degrees of abnormality from a random Central European population sample with a homogeneous subset of healthy subjects. METHODS: We analysed echocardiograms obtained in a randomly selected population sample during the Czech post-MONICA survey in 2007/2008. Overall, 1850 out of 2273 persons of the whole sample of three districts had adequate echocardiograms (81.4%). A healthy subgroup defined by the absence of known cardiovascular disease was used to define normal reference range limits (n = 575, median age 42 years [IQR 34-52], 57% females). The whole population sample with predefined percentile cut-offs was used to define degrees of abnormality. RESULTS: Left ventricular (LV) size tended to decrease with age, while LV mass increased with age in both males and females and in both the healthy and general populations. LV dimensions were larger in males, except for body surface area-indexed LV diameter. M-mode derived LV measurements were larger and LV mass higher compared to 2D measurements. Right ventricle basal dimension was larger in males. CONCLUSIONS: Our study provides reference ranges for echocardiographic measurements obtained in a healthy subgroup derived from an epidemiological study of a Central European population. Where feasible, degrees of abnormality are provided based on the whole population sample including patients with disease. Our data show that age, gender and measurement method significantly affect cardiac dimensions and function and should be always taken into account.
- MeSH
- dospělí MeSH
- echokardiografie metody MeSH
- funkce levé komory srdeční fyziologie MeSH
- kardiovaskulární nemoci diagnóza patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- referenční hodnoty MeSH
- senioři MeSH
- srdeční komory diagnostické zobrazování MeSH
- srdeční síně diagnostické zobrazování MeSH
- surveillance populace * MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Geografické názvy
- Česká republika MeSH
Cardiovascular diseases are one of most frequent cause of morbidity and mortality in the world. There is an emerging need for integrated, non-invasive, and easy-to-use clinical tools to assess accurately cardiovascular system primarily in the preventative medicine. We present a novel design for a non-invasive pulse wave velocity (PWV) assessment method integrated in a single brachial blood pressure monitor allowing for up to 100 times more sensitive recording of the pressure pulsations based on a brachial occlusion-cuff (suprasystolic) principle. The monitor prototype with built-in proprietary method was validated with a gold standard reference technique SphygmoCor VX device. The blood pressure and PWV were assessed on twenty-five healthy individuals (9 women, age (37 ± 13) years) in a supine position at rest by a brachial cuff blood pressure monitor prototype, and immediately re-tested using a gold standard method. PWV using our BP monitor was (6.67 ± 0.96) m/s compared to PWV determined by SphygmoCor VX (6.15 ± 1.01) m/s. The correlation between methods using a Pearson's correlation coefficient was r = 0.88 (p < 0.001). The study demonstrates the feasibility of using a single brachial cuff build-in technique for the assessment of the arterial stiffness from a single ambulatory blood pressure assessment.
- Publikační typ
- časopisecké články MeSH